The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Simultaneous Single Unit Recording in vitro with a Photoetched Laser Deinsulated Gold Multimicroelectrode Surface
Abstract
Flat photoetched gold conductors 12 μm wide and 2 μm thick, situated on a glass plate and deinsulated at their tips with single 8 ns UV laser pulses, have been utilized to record single unit extra-cellular activity from brain ganglia of the snail Helix pomatia. A fixed array of 36 such conductors, terminating in six rows and six columns in a 0.5 mm x 1 mm area, is capable of monitoring simultaneous single unit activity from numerous neurons. Spike amplitudes of 300-500 μV are generally observed from the predominant 40 μm diameter cells of these ganglia. Giant neurons usually produce signal amplitudes of over 3 mV that are simultaneously seen by many electrodes. Signals can be monitored by merely resting a locally desheathed ganglion on the recording area under its own weight in a shallow pool of Ringer. A 10 μm diameter crater in a 3-4 μm thick insulation layer has an impedance of 2-4 MΩat 1 kHz. The capacitance of this metal electrolyte interface is about 0.5 pF/μm2, suggesting that the UV laser produces a partially colloidal gold surface. With this recessed tip design, simultaneous single unit recording from small neurons appears ensured if electrode impedances are below 4 MΩ, shunt impedances are above 30 MΩ, and glia cells are not allowed to reinsulate the end of the gold conductor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.560 · Cited by 2,294
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
The physiology of neuroglial cells
Kuffler, S. W., & Nicholls, J. G. (1966) · Ergebnisse der Physiologie Biologischen Chemie und Experimentellen Pharmakologie · doi:10.1007/bf02259903 · Cited by 462
The physiology of neuroglial cells
Kuffler, S. W., & Nicholls, J. G. (2007) · Ergebnisse der Physiologie Biologischen Chemie und Experimentellen Pharmakologie · doi:10.1007/bfb0116991 · Cited by 416
A voltage‐sensitive persistent calcium conductance in neuronal somata of Helix.
Eckert, R., & Lux, H. D. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011225 · Cited by 306
Gesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. H. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 301
Gross, G. W., Rieske, E., Kreutzberg, G. W., & Meyer, A. (1977) · Neuroscience Letters · doi:10.1016/0304-3940(77)90003-9 · Cited by 297
Self-citationNeurophysiologic studies in tissue culture
Crain, S. M. (1976) · Cited by 177
A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology
Wise, K. D., & Angell, J. B. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324562 · Cited by 159
Neurons from fetal rat brain in a new cell culture system: A multidisciplinary analysis
Godfrey, E. W., Nelson, P. G., Schrier, B. K., Breuer, A. C., & Ransom, B. R. (1975) · Brain Research · doi:10.1016/0006-8993(75)90679-4 · Cited by 126
Bioelectric Recording Techniques
(1974) · Elsevier eBooks · doi:10.1016/c2013-0-11595-4 · Cited by 121
Loeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46
An Evaluation of Photoengraved Microelectrodes for Extracellular Single-Unit Recording
Starr, A., Wise, K. D., & Csongradi, J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324194 · Cited by 34
A compact amplifier for extracellular recording
Brakel, S., Babb, T. L., Mahnke, J., & Verzeano, M. (1971) · Physiology & Behavior · doi:10.1016/0031-9384(71)90264-2 · Cited by 25
Cited by
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Recording action potentials from cultured neurons with extracellular microcircuit electrodes
Pine, J. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90042-4 · Cited by 543
Oka, H., Shimono, K., Ogawa, R., Sugihara, H., & Taketani, M. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00113-2 · Cited by 317
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
The Neurally Controlled Animat: Biological Brains Acting with Simulated Bodies
DeMarse, T. B., Wagenaar, D. A., Blau, A. W., & Potter, S. M. (2001) · Autonomous Robots · doi:10.1023/a:1012407611130 · Cited by 276
Metadata
- Authors
- Gross, G. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1979-05
- Volume
- BME-26
- Issue
- 5
- Pages
- 273-279
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2079316730
- Cited by
- 324
- References
- 17
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.