A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
The cuff electrode provides a stable interface with the peripheral nerve, which has been widely utilized in both basic research and clinical practice over the past few decades. In this paper, we present a microfabricated, parylene-based self-locking cuff electrode. The cuff diameter can be adjusted to accommodate the nerve properly during implantation. This type of cuff electrodes is easy to implant and the cuff was made of the thin, flexible, and biocompatible parylene substrate. Moreover, the integrated parylene cable and pads facilitate the connection with external circuits. Electrochemical properties of electrode sites were characterized by impedance spectroscopy and cyclic voltammetry. The average impedance magnitude and average charge delivery capacity of the Pt electrodes are 8.3 kQ (at 1 kHz) and 2.8 mC/cm2, respectively. Using the proposed cuff electrodes, the evoked compound action potentials of the rat sciatic nerve were successfully recorded. Electrical stimulation tests proved the feasibility of selective stimulation of tibial and peroneal fascicles within the rat sciatic nerve. This type of cuff electrodes induced only a benign foreign body reaction and did not damage the axons within the rat sciatic nerve over 11 weeks of an implantation period.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various adapted peripheral electrodes have been proposed, such as implants around the nerve (cuff electrodes[351] and flat interface nerve electrodes (FINE)[352]), longitudinally through the nerves (wire[353] and longitudinal interfascicular electrodes (LIFE)[354]), and through the nerves via shafts (such as transverse interfascicular multichannel electrodes (TIME)[355]).”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [351]
In the citing paper
“Acute and chronic (11 weeks) implantation in rat sciatic nerve demonstrated its capability of selective stimulation.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [63]
In the citing paper
“For instance, selectively recruiting different layers in the peripheral nerve results in a graded force generation in various muscle groups23–25.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [23]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“Therefore, tissue damage induced by system power and stimulation can be minimized [22].”
BackgroundNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Reversing pathological neural activity using targeted plasticity
Engineer, N. D., Riley, J. R., Seale, J. D., Vrana, W. A., Shetake, J. A., Sudanagunta, S. P., Borland, M. S., & Kilgard, M. P. (2011) · Nature · doi:10.1038/nature09656 · Cited by 668
Chronic vagus nerve stimulation: A new and promising therapeutic approach for chronic heart failure
De Ferrari, G. M., Crijns, H. J. G. M., Borggrefe, M., Milasinovic, G., Smid, J., Zabel, M., Gavazzi, A., Sanzo, A., Dennert, R., Kuschyk, J., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq391 · Cited by 523
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 1×
“intrafascicular electrodes that are placed within fascicles in the nerve and directly contacted with the target fibers, such as fine wires [26], [27] and silicon or polyimide probes [28], [29], cuff electrodes are safer and more reliable for chronic implan-”
BackgroundA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 2×
“Additionally, the bulky and inflexible cuff and lead wires may cause neural damage due to possible stretching or rubbing of the nerve after implantation [46].”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
Micromachining of Parylene C for bioMEMS
Kim, B. J., & Meng, E. (2016) · Polymers for Advanced Technologies · doi:10.1002/pat.3729 · Cited by 204
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Review of polymer MEMS micromachining
Kim, B., & Meng, E. F. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/1/013001 · Cited by 171
Metadata
- Authors
- Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z.
- Affiliations
- Peking University (CN)
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2014-10
- Volume
- 23
- Issue
- 5
- Pages
- 1025-1035
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2067747145
- Semantic Scholar
- 4be6eaa64a2a5f85a34042d10fe2d9155bdaca3a
- Cited by
- 56
- References
- 63
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 5 · 2023: 3 · 2022: 4 · 2021: 11 · 2020: 1 · 2019: 5 · 2018: 9 · 2017: 5 · 2016: 6 · 2015: 3
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Microelectromechanical Systems (publishedVersion)
- Funders
- National Basic Research Program of China (2011CB707505)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- cuff electrodes, parylene, peripheral nerve stimulation, peripheral nerve recording, microfabrication, electrode impedance, platinum electrode, sciatic nerve, compound action potential, foreign body reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording. https://app.cochat.ai/papers/10.1109/jmems.2014.2333733
- The paper
- Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014). A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2014.2333733
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.