The Strength-Duration Curve

Geddes, L. A., Bourland, J. D.·1985·IEEE Transactions on Biomedical Engineering

Abstract

The strength-duration curve is a plot of the lowest (threshold) current (I) required for stimulation versus pulse duration (d); it forms the basis for describing the excitability of a given tissue. It is extremely useful in all manner of studies in which excitable tissues are stimulated because it describes the manner in which the current required is changed when the pulse duration is changed. Moreover, it can be used to determine the charge and energy-duration relationships. It will be the objective of this communication to show how the essential constants can be obtained.

Integrity signals

Registry

Crossref · 10.1109/tbme.1985.325456

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The relationship between charge and neuron activation is defined by the strength-duration curve, the threshold current amplitude required for neuron stimulation for a given pulse width.

    “The relationship between charge and neuron activation is defined by the strength-duration curve, the threshold current amplitude required for neuron stimulation for a given pulse width [115], [116]”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Geddes, L. A., & Bourland, J. D.
Affiliations
Purdue University West Lafayette (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1985-06
Volume
BME-32
Issue
6
Pages
458-459
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2111920833
Cited by
128
References
5
Citations by year
2026: 2 · 2025: 5 · 2024: 5 · 2023: 8 · 2022: 9 · 2021: 9 · 2020: 8 · 2019: 6 · 2018: 4 · 2017: 5 · 2016: 4 · 2015: 6 · 2014: 2 · 2013: 4 · 2012: 1
FWCI
0.44
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
strength-duration curve, threshold current, pulse duration, excitable tissues
MeSH terms
Chronaxy, Electric Stimulation, Humans

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review