Kinetic Modeling of the Glucoregulatory System to Improve Insulin Therapy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
For simulating glucose-insulin control systems with respect to application in an optimized therapy of insulin-dependent diabetes, a global transfer model was generated and supplemented with a structural model of the opened control circuit. The transfer characteristics within the established linear range of the intact system, which is identical with the range of euglycaemia, can be described by a 4th-order differential equation. A test strategy was developed to identify the state variables of the opened, i. e., of the diabetic, system and to determine by pole assignment those control constants of glucose-controlled insulin provision that are optimally adapted to a given set of state variables. The model system was verified by the prediction of plasma insulin and blood glucose reponses to various loads of glucose and/or insulin, by isotopic studies (U-14C-glucose) of glucose turnover, and by predicting the rates of absorption (i. e., of appearance within the distribution space) of orally administered glucose. The latter situations provide fields of application for this model strategy in addition to the main goal, namely, the individual optimization of control parameters for open-loop or closed-loop insulin therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coefficients of normal blood glucose regulation
Bolie, V. W. (1961) · Journal of Applied Physiology · doi:10.1152/jappl.1961.16.5.783 · Cited by 349
Experimental validation of measurements of glucose turnover in nonsteady state.
Radziuk, J., Norwich, K. H., & Vranic, M. (1978) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1978.234.1.e84 · Cited by 277
Research works printed but not linked: 38
- 10.2337/diab.33.2.184 · DOI
- 10.1007/BF01059059 · DOI
- 10.1016/0025-5564(82)90050-5 · DOI · Paper page
- 10.1088/0031-9155/9/2/307 · DOI · Paper page
- 10.1210/jcem-47-5-1160 · DOI · Paper page
- cobelli, 1983, is the pool-fraction paradigm a valid model for assessment of in vivo turnover in non-steady state?, Amer J Physiol, 245, 624r
- 10.1139/y79-191 · DOI
- tiran, 1980, glucose and insulin dynamics in the anaesthetized dog: a mathematical modelling study, Med Progr Technol, 7, 183
- 10.1109/TBME.1983.325203 · DOI · Paper page
- salzsieder, 1984, Verfahren und Anordnung zur prospektiven automatischen Bestimmung individual spezifischer glukoseregulationsparameter
- horwitz, 1978, algorithm flexibility in an artificial beta-cell for control of diabetes, Diabetes, 271, 482
- atkins, 1981, Carbohydrate Metabolism, 369
- bergman, 1981, Carbohydrate Metabolism, 269
- garfinkel, 1983, a mathematics forphysiology, Amer J Physiol, 245, 455r
- iserman, 1979, Digitale Regelsysteme Berlin, 190
- kikuchi, 1982, adaptive blood glucose control system designed via state space approaches, World Congr Med Phys Biomed Eng
- 10.1007/BF02478212 · DOI
- novoseltsev, 1977, control theory and living systems, Prace Instytutu Biocybernetyki
- 10.1016/0010-4809(80)90024-5 · doi:10.1016/0010-4809(80)90024-5
- bergman, 1974, interaction of insulin and glucose in the control of hepatic glucose balance, Amer J Physiol, 227, 1314, 10.1152/ajplegacy.1974.227.6.1314 · DOI
- salzsieder, 1984, estimation of individually adapted control parameters for an artificial beta cell, Biomed Biochim Acta, 43, 585
- 10.1007/BF00282520 · DOI
- fischer, 1983, Can the control characteristics of the physiological glucose-insulin relationship be applied to an algorithm for closed-loop insulin infusion in diabetes??Proposal for a strategy to determine to control parameters, 381
- 10.1007/BF02442800 · DOI
- fischer, 1984, modelling the glucose-insulin system as a basis for the artificial beta cell, Biomed Biochim Acta, 43, 597
- 10.1055/s-0029-1210324 · doi:10.1055/s-0029-1210324
- salzsieder, 1981, a computer algorithm for the artificial fl-cell based upon analysis of the controlled system in diabetes, Artif Organs, 5, 286
- 10.1109/TBME.1983.325181 · doi:10.1109/tbme.1983.325181
- fischer, 1983, note the artificial beta cell algorithms but their parameter values are important in automated glucose control of insulin-dependent diabetes, Trans Amer Soc Artif Intern Organs, 29, 488
- salzsieder, 1982, estimation of individually adapted parameters of an artificial b-cell based on a model of the glucoregulatory system, Proc Int Symp Kinetic Modelling in Artificial Organs, 335
- 10.2337/diacare.3.2.266 · DOI
- fischer, 1978, derivation and experimental proof of a new algorithm for the artificial b-cell based on the individual analysis of the physiological insulin-glucose relationship, Endocrinology, 71, 65
- lassen, 1979, Tracerkinetic Methods in Medical Physiology
- 10.1007/BF00290484 · DOI
- freyse, 1982, low dose streptozotozin diabetes after partial pancreatectomy in dogs, Acta Biol Med Germ, 41, 1203
- 10.1007/BF02442625 · DOI
- abel, 1983, kontinuierliche bes timmung der blutglukose mittels enzymelektrode, Z Med Labor Diagn, 24, 264
- gottschling, 1974, radioimmunoassy von plasmainsulin-methodenkritische untersuchungen, Radiobiol Radiother, 15, 91
Cited by
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
“The development of advanced algorithms followed (Fischer et al 1990, Fisher and Teo 1989, Kienitz and Yoneyama 1993, Ollerton 1989, Salzsieder et al 1985, Shichiri et al 1983, Swan 1982).”
MethodMeal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Metadata
- Authors
- Salzsieder, E., Albrecht, G., Fischer, U., & Freyse, E.-J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1985-10
- Volume
- BME-32
- Issue
- 10
- Pages
- 846-855
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1984227372
- Cited by
- 102
- References
- 2
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.