CoChat

Kinetic Modeling of the Glucoregulatory System to Improve Insulin Therapy

Salzsieder, E., Albrecht, G., Fischer, U., Freyse, E.-J. · 1985 · IEEE Transactions on Biomedical Engineering
Cited by 102

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

For simulating glucose-insulin control systems with respect to application in an optimized therapy of insulin-dependent diabetes, a global transfer model was generated and supplemented with a structural model of the opened control circuit. The transfer characteristics within the established linear range of the intact system, which is identical with the range of euglycaemia, can be described by a 4th-order differential equation. A test strategy was developed to identify the state variables of the opened, i. e., of the diabetic, system and to determine by pole assignment those control constants of glucose-controlled insulin provision that are optimally adapted to a given set of state variables. The model system was verified by the prediction of plasma insulin and blood glucose reponses to various loads of glucose and/or insulin, by isotopic studies (U-14C-glucose) of glucose turnover, and by predicting the rates of absorption (i. e., of appearance within the distribution space) of orally administered glucose. The latter situations provide fields of application for this model strategy in addition to the main goal, namely, the individual optimization of control parameters for open-loop or closed-loop insulin therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1985.325500

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 38

  1. 10.2337/diab.33.2.184 · DOI
  2. 10.1007/BF01059059 · DOI
  3. 10.1016/0025-5564(82)90050-5 · DOI · Paper page
  4. 10.1088/0031-9155/9/2/307 · DOI · Paper page
  5. 10.1210/jcem-47-5-1160 · DOI · Paper page
  6. cobelli, 1983, is the pool-fraction paradigm a valid model for assessment of in vivo turnover in non-steady state?, Amer J Physiol, 245, 624r
  7. 10.1139/y79-191 · DOI
  8. tiran, 1980, glucose and insulin dynamics in the anaesthetized dog: a mathematical modelling study, Med Progr Technol, 7, 183
  9. 10.1109/TBME.1983.325203 · DOI · Paper page
  10. salzsieder, 1984, Verfahren und Anordnung zur prospektiven automatischen Bestimmung individual spezifischer glukoseregulationsparameter
  11. horwitz, 1978, algorithm flexibility in an artificial beta-cell for control of diabetes, Diabetes, 271, 482
  12. atkins, 1981, Carbohydrate Metabolism, 369
  13. bergman, 1981, Carbohydrate Metabolism, 269
  14. garfinkel, 1983, a mathematics forphysiology, Amer J Physiol, 245, 455r
  15. iserman, 1979, Digitale Regelsysteme Berlin, 190
  16. kikuchi, 1982, adaptive blood glucose control system designed via state space approaches, World Congr Med Phys Biomed Eng
  17. 10.1007/BF02478212 · DOI
  18. novoseltsev, 1977, control theory and living systems, Prace Instytutu Biocybernetyki
  19. 10.1016/0010-4809(80)90024-5 · doi:10.1016/0010-4809(80)90024-5
  20. bergman, 1974, interaction of insulin and glucose in the control of hepatic glucose balance, Amer J Physiol, 227, 1314, 10.1152/ajplegacy.1974.227.6.1314 · DOI
  21. salzsieder, 1984, estimation of individually adapted control parameters for an artificial beta cell, Biomed Biochim Acta, 43, 585
  22. 10.1007/BF00282520 · DOI
  23. fischer, 1983, Can the control characteristics of the physiological glucose-insulin relationship be applied to an algorithm for closed-loop insulin infusion in diabetes??Proposal for a strategy to determine to control parameters, 381
  24. 10.1007/BF02442800 · DOI
  25. fischer, 1984, modelling the glucose-insulin system as a basis for the artificial beta cell, Biomed Biochim Acta, 43, 597
  26. 10.1055/s-0029-1210324 · doi:10.1055/s-0029-1210324
  27. salzsieder, 1981, a computer algorithm for the artificial fl-cell based upon analysis of the controlled system in diabetes, Artif Organs, 5, 286
  28. 10.1109/TBME.1983.325181 · doi:10.1109/tbme.1983.325181
  29. fischer, 1983, note the artificial beta cell algorithms but their parameter values are important in automated glucose control of insulin-dependent diabetes, Trans Amer Soc Artif Intern Organs, 29, 488
  30. salzsieder, 1982, estimation of individually adapted parameters of an artificial b-cell based on a model of the glucoregulatory system, Proc Int Symp Kinetic Modelling in Artificial Organs, 335
  31. 10.2337/diacare.3.2.266 · DOI
  32. fischer, 1978, derivation and experimental proof of a new algorithm for the artificial b-cell based on the individual analysis of the physiological insulin-glucose relationship, Endocrinology, 71, 65
  33. lassen, 1979, Tracerkinetic Methods in Medical Physiology
  34. 10.1007/BF00290484 · DOI
  35. freyse, 1982, low dose streptozotozin diabetes after partial pancreatectomy in dogs, Acta Biol Med Germ, 41, 1203
  36. 10.1007/BF02442625 · DOI
  37. abel, 1983, kontinuierliche bes timmung der blutglukose mittels enzymelektrode, Z Med Labor Diagn, 24, 264
  38. gottschling, 1974, radioimmunoassy von plasmainsulin-methodenkritische untersuchungen, Radiobiol Radiother, 15, 91

Cited by

Metadata

Authors
Salzsieder, E., Albrecht, G., Fischer, U., & Freyse, E.-J.
Venue
IEEE Transactions on Biomedical Engineering
Published
1985-10
Volume
BME-32
Issue
10
Pages
846-855
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1984227372
Cited by
102
References
2
FWCI
0.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.