Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Thin-film arrays of extracellular recording electrodes have been developed for use in studies of information processing in neural structures and eventual use in closed-loop control of neural prostheses. These probes consist of a silicon substrate which supports an array of thin-film conductors. The conductors are insulated above and below with deposited dielectrics. The electrode sites are defined by openings in the upper dielectric layer and are inlaid with gold to form low-impedance recording surfaces. The probes are typically 15 pim in thickness with shank widths as narrow as 20 μm. The probe fabrication process is compatible with the inclusion of signal processing circuitry directly on the probe substrate. A 12 channel on-chip signal processor design with per-channel gain of 100, bandwidth of 100 Hz-6 kHz, multiplexed output, and recording-site impedance check capability is described. The probes have adequate strength to penetrate the gerbil pia-arachnoid layer and have recorded single neuron activity of over 500 μV peak-to-peak from tip, side, and mid-carrier sites. Signal-to-noise ratios as high as 10:1 have been achieved. An equivalent circuit model for the conducting leads, the recording site, and the electrode-electrolyte interface is described. Development of biocompatible insulation and encapsulation materials for long-term implantation of active probes is underway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 3×
“[8], [10], [18], [19], Kuperstein and Whittington [20], White et al.”
BackgroundResultSelf-citation
Cited by
Microfabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“trode’ [38].”
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Self-citation
Metadata
- Authors
- BeMent, S. L., Wise, K. D., Anderson, D. J., Najafi, K., & Drake, K. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1986-02
- Volume
- BME-33
- Issue
- 2
- Pages
- 230-241
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2046259037
- Cited by
- 142
- References
- 1
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.