Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Thin-film arrays of extracellular recording electrodes have been developed for use in studies of information processing in neural structures and eventual use in closed-loop control of neural prostheses. These probes consist of a silicon substrate which supports an array of thin-film conductors. The conductors are insulated above and below with deposited dielectrics. The electrode sites are defined by openings in the upper dielectric layer and are inlaid with gold to form low-impedance recording surfaces. The probes are typically 15 pim in thickness with shank widths as narrow as 20 μm. The probe fabrication process is compatible with the inclusion of signal processing circuitry directly on the probe substrate. A 12 channel on-chip signal processor design with per-channel gain of 100, bandwidth of 100 Hz-6 kHz, multiplexed output, and recording-site impedance check capability is described. The probes have adequate strength to penetrate the gerbil pia-arachnoid layer and have recorded single neuron activity of over 500 μV peak-to-peak from tip, side, and mid-carrier sites. Signal-to-noise ratios as high as 10:1 have been achieved. An equivalent circuit model for the conducting leads, the recording site, and the electrode-electrolyte interface is described. Development of biocompatible insulation and encapsulation materials for long-term implantation of active probes is underway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 3×
“[8], [10], [18], [19], Kuperstein and Whittington [20], White et al.”
BackgroundResultSelf-citation
Cited by
Microfabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“trode’ [38].”
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Self-citationSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Challenges and opportunities for large-scale electrophysiology with Neuropixels probes
Steinmetz, N. A., Koch, C., Harris, K. D., & Carandini, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.009 · Cited by 333
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Self-citationMobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationMultiple microelectrode-recording system for human intracortical applications
Ulbert, I., Halgren, E., Heit, G., & Karmos, G. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00330-2 · Cited by 173
“Printed circuit electrodes (PCE) (Wise and Starr, 1970; Kuperstein and Eichenbaum, 1985; BeMent et al., 1985; Wise and Drake, 1986; Prohaska and Dragun, 1986; Kewley et al., 1997; Nádasdy et al., 1998) which are made by thin layer microelectronics technologies.”
BackgroundStrength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Self-citationSensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“Multielectrode approaches (12, 13) provided early examples of real-time prediction of an animal’s wrist position from the decoded motor cortex output (14, 15) and enabled animals to perform simple tasks via an external device (16).”
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
A perspective on cortical layering and layer-spanning neuronal elements
Larkum, M. E., Petro, L. S., Sachdev, R. N. S., & Muckli, L. (2018) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2018.00056 · Cited by 102
“Standard methodologies such as vertically oriented linear arrays like Michigan Probes have long been useful for probing laminar issues (BeMent et al., 1986; Cauller and Kulics, 1991) and can be used to probe the relative influence of feed forward and feedback influences in the cortex (van Kerkoerle…”
BackgroundInterfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
The cone electrode: Ultrastructural studies following long-term recording in rat and monkey cortex
Kennedy, P. R., Mirra, S. S., & Bakay, R. A. E. (1992) · Neuroscience Letters · doi:10.1016/0304-3940(92)90627-j · Cited by 81
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71
Flexible miniature ribbon cables for long‐term connection to implantable sensors
Hetke, J. F., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(90)87076-u · Cited by 33
Self-citation
Metadata
- Authors
- BeMent, S. L., Wise, K. D., Anderson, D. J., Najafi, K., & Drake, K. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1986-02
- Volume
- BME-33
- Issue
- 2
- Pages
- 230-241
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2046259037
- Cited by
- 142
- References
- 1
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.