The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Open accessAbstract
An ambulatory gait analysis method using body-attached gyroscopes to estimate spatio-temporal parameters of gait has been proposed and validated against a reference system for normal and pathologic gait. Later, ten Parkinson's disease (PD) patients with subthalamic nucleus deep brain stimulation (STN-DBS) implantation participated in gait measurements using our device. They walked one to three times on a 20-m walkway. Patients did the test twice: once STN-DBS was ON and once 180 min after turning it OFF. A group of ten age-matched normal subjects were also measured as controls. For each gait cycle, spatio-temporal parameters such as stride length (SL), stride velocity (SV), stance (ST), double support (DS), and gait cycle time (GC) were calculated. We found that PD patients had significantly different gait parameters comparing to controls. They had 52% less SV, 60% less SL, and 40% longer GC. Also they had significantly longer ST and DS (11% and 59% more, respectively) than controls. STN-DBS significantly improved gait parameters. During the stim ON period, PD patients had 31% faster SV, 26% longer SL, 6% shorter ST, and 26% shorter DS. GC, however, was not significantly different. Some of the gait parameters had high correlation with Unified Parkinson's Disease Rating Scale (UPDRS) subscores including SL with a significant correlation (r = -0.90) with UPDRS gait subscore. We concluded that our method provides a simple yet effective way of ambulatory gait analysis in PD patients with results confirming those obtained from much more complex and expensive methods used in gait labs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Unified Parkinson's Disease Rating Scale
(2012) · SpringerReference · doi:10.1007/springerreference_184495 · Cited by 3,066
Introduction to the Theory and Practice of Econometrics
Ziegel, E. (1989) · Technometrics · doi:10.1080/00401706.1989.10488621 · Cited by 2,239
Parkinson, J. (2002) · The Journal of Neuropsychiatry and Clinical Neurosciences · doi:10.1176/jnp.14.2.223 · Cited by 1,628
Introduction to the Theory and Practice of Econometrics.
Judge, G. G., Hill, C., Griffiths, W. E., Lutkepohl, H., & Lee, T.-C. (1988) · Journal of the American Statistical Association · doi:10.2307/2290184 · Cited by 1,104
Assessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Self-citationA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
How do parkinsonian signs return after discontinuation of subthalamic DBS?
Temperli, P., Ghika, J., Villemure, J.-G., Burkhard, P. R., Bogousslavsky, J., & Vingerhoets, F. J. G. (2003) · Neurology · doi:10.1212/wnl.60.1.78 · Cited by 418
Self-citationUnified Parkinson’s Disease Rating Scale
Fish, J. (2018) · Encyclopedia of Clinical Neuropsychology · doi:10.1007/978-3-319-57111-9_1836 · Cited by 403
Long-Term Electrical Inhibition of Deep Brain Targets in Movement Disorders
Benabid, A. L., Benazzouz, A., Hoffmann, D., Limousin, P., Krack, P., & Pollak, P. (2008) · Movement Disorders · doi:10.1002/mds.870131321 · Cited by 375
Subthalamic DBS replaces levodopa in Parkinson’s disease: Two-year follow-up
Vingerhoets, F. J. G., Villemure, J.-G., Temperli, P., Pollo, C., Pralong, E., & Ghika, J. (2002) · Neurology · doi:10.1212/wnl.58.3.396 · Cited by 314
Self-citationDiscrimination of walking patterns using wavelet-based fractal analysis
Sekine, M., TAMURA, T., Akay, M., Fujimoto, T., Togawa, T., & Fukui, Y. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802879 · Cited by 201
Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169
Aminian, K., Rezakhanlou, K., Andres, E. D., Fritsch, C., Leyvraz, P., & Robert, P. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513368 · Cited by 165
Self-citationConstraints on the kinetic, kinematic and spatiotemporal parameters of gait in Parkinson's disease
Morris, M. E., McGinley, J. L., Huxham, F. E., Collier, J. M., & Iansek, R. (1999) · Human Movement Science · doi:10.1016/s0167-9457(99)00020-2 · Cited by 145
Quantification of the UPDRS rigidity scale
Patrick, S. K., Denington, A. A., Gauthier, M. J. A., et al. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918274 · Cited by 91
An ambulatory system to quantify bradykinesia and tremor in Parkinson's disease
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Burkhard, P. R., Blanc, Y., Dehollain, C., & Aminian, K. (2003) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2003.1222415 · Cited by 38
Self-citation
Cited by
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
iTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489
Self-citationPasluosta, C. F., Gassner, H., Winkler, J., Klucken, J., & Eskofier, B. M. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2461555 · Cited by 323
Caramia, C., Torricelli, D., Schmid, M., Munoz-Gonzalez, A., Gonzalez-Vargas, J., Grandas, F., & Pons, J. L. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2865218 · Cited by 243
Godinho, C., Domingos, J., Cunha, G., Santos, A. T., Fernandes, R. M., Abreu, D., Gonçalves, N., Matthews, H., Isaacs, T., Duffen, J., et al. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0136-7 · Cited by 226
Metadata
- Authors
- Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-08
- Volume
- 51
- Issue
- 8
- Pages
- 1434-1443
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2162908184
- Cited by
- 659
- References
- 20
- FWCI
- 15.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.