CoChat

Insulin Kinetics in Type-1 Diabetes: Continuous and Bolus Delivery of Rapid Acting Insulin

Wilinska, M.E., Chassin, L.J., Schaller, H.C., Schaupp, L., Pieber, T.R., Hovorka, R. · 2005 · IEEE Transactions on Biomedical Engineering
Cited by 237

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We investigated insulin lispro kinetics with bolus and continuous subcutaneous insulin infusion (CSII) modes of insulin delivery. Seven subjects with type-1 diabetes treated by CSII with insulin lispro have been studied during prandial and postprandial conditions over 12 hours. Eleven alternative models of insulin kinetics have been proposed implementing a number of putative characteristics. We assessed 1) the effect of insulin delivery mode, i.e., bolus or basal, on the insulin absorption rate, the effects of 2) insulin association state and 3) insulin dose on the rate of insulin absorption, 4) the remote insulin effect on its volume of distribution, 5) the effect of insulin dose on insulin disappearance, 6) the presence of insulin degradation at the injection site, and finally 7) the existence of two pathways, fast and slow, of insulin absorption. An iterative two-stage parameter estimation technique was used. Models were validated through assessing physiological feasibility of parameter estimates, posterior identifiability, and distribution of residuals. Based on the principle of parsimony, best model to fit our data combined the slow and fast absorption channels and included local insulin degradation. The model estimated that 67(53-82)% [mean (interquartile range)] of delivered insulin passed through the slow absorption channel [absorption rate 0.011(0.004-0.029) min(-1)] with the remaining 33% passed through the fast channel [absorption rate 0.021(0.011-0.040) min(-1)]. Local degradation rate was described as a saturable process with Michaelis-Menten characteristics [VMAX = 1.93(0.62 - 6.03) mU min(-1), KM = 62.6(62.6 - 62.6) mU]. Models representing the dependence of insulin absorption rate on insulin disappearance and the remote insulin effect on its volume of distribution could not be validated suggesting that these effects are not present or cannot be detected during physiological conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2004.839639

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 237

Metadata

Authors
Wilinska, M. E., Chassin, L. J., Schaller, H. C., Schaupp, L., Pieber, T. R., & Hovorka, R.
Venue
IEEE Transactions on Biomedical Engineering
Published
2005-01
Volume
52
Issue
1
Pages
3-12
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2163532367
Cited by
237
References
4
FWCI
4.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.