Painless Drug Delivery Through Microneedle-Based Transdermal Patches Featuring Active Infusion
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents the first microneedle-based transdermal patch with integrated active dispensing functionality. The electrically controlled system consists of a low-cost dosing and actuation unit capable of controlled release of liquid in the microliter range at low flow-rates and minimally invasive, side-opened, microneedles. The system was successfully tested in vivo by insulin administration to diabetic rats. Active infusion of insulin at 2 mul/h was compared to passive, diffusion-driven, delivery. Continuous active infusion caused significantly higher insulin concentrations in blood plasma. After a 3-h delivery period, the insulin concentration was five times larger compared to passive delivery. Consistent with insulin concentrations, actively administered insulin resulted in a significant decrease of blood glucose levels. Additionally, insertion and liquid injection was verified on human skin. This study shows the feasibility of a patch-like system with on-board liquid storage and dispensing capability. The proposed device represents a first step towards painless and convenient administration of macromolecular drugs such as insulin or vaccines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859 · cited 3×
“However, these studies report pharmacodynamic response (blood glucose [10], [11] and blood flux [5]) and the actual amount of drug delivered was not quantified.”
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413 · cited 3×
“However, these studies report pharmacodynamic response (blood glucose [10], [11] and blood flux [5]) and the actual amount of drug delivered was not quantified.”
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Microneedle technologies for (trans)dermal drug and vaccine delivery
van der Maaden, K., Jiskoot, W., & Bouwstra, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.042 · Cited by 651
Nanotechnology and the transdermal routeA state of the art review and critical appraisal
Cevc, G., & Vierl, U. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.10.016 · Cited by 560
Metadata
- Authors
- Roxhed, N., Samel, B., Nordquist, L., Griss, P., & Stemme, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2008-03
- Volume
- 55
- Issue
- 3
- Pages
- 1063-1071
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2160086358
- Cited by
- 151
- References
- 2
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Painless Drug Delivery Through Microneedle-Based Transdermal Patches Featuring Active Infusion. https://app.cochat.ai/papers/10.1109/tbme.2007.906492
- The paper
- Roxhed, N., Samel, B., Nordquist, L., Griss, P., & Stemme, G. (2008). Painless Drug Delivery Through Microneedle-Based Transdermal Patches Featuring Active Infusion. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2007.906492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.