The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent
Abstract
This paper presents a fully wireless cardiac pressure sensing system. Food and Drug Administration (FDA) approved medical stents are explored as radiating structures to support simultaneous transcutaneous wireless telemetry and powering. An application-specific integrated circuit (ASIC), designed and fabricated using the Texas Instruments 130-nm CMOS process, enables wireless telemetry, remote powering, voltage regulation, and processing of pressure measurements from a microelectromechanical systems (MEMS) capacitive sensor. This paper demonstrates fully wireless-pressure-sensing functionality with an external 35-dB.m RF powering source across a distance of 10 cm. Measurements in a regulated pressure chamber demonstrate the ability of the cardiac system to achieve pressure resolutions of 0.5 mmHg over a range of 0-50 mmHg using a channel data-rate of 42.2 kb/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Cited by
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
Chow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
Self-citationNear-Field Wireless Power Transfer to Stent-Based Biomedical Implants
Wiseman, G., Redoute, J.-M., Ganesan, K., Rind, G. S., John, S. E., Ronayne, S. M., Opie, N. L., Garrett, D. J., & Prawer, S. (2018) · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2018.2833386 · Cited by 49
A broad dual-band implantable antenna for RF energy harvesting and data transmitting
Fan, Y., Liu, X., & Xu, C. (2022) · Micromachines · doi:10.3390/mi13040563 · Cited by 33
“These IMDs include blood pressure monitors [2], cochlear implants [3], and implantable pacemakers [4], and others.”
Background
Metadata
- Authors
- Chow, E. Y., Chlebowski, A. L., Chakraborty, S., Chappell, W. J., & Irazoqui, P. P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-06
- Volume
- 57
- Issue
- 6
- Pages
- 1487-1496
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2155723826
- Cited by
- 222
- References
- 1
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.