CoChat

Multisensor Data Fusion for Physical Activity Assessment

Shaopeng Liu, Gao, Robert X., John, D., Staudenmayer, J. W., Freedson, P. S. · 2012 · IEEE Transactions on Biomedical Engineering
Cited by 147

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This paper presents a sensor fusion method for assessing physical activity (PA) of human subjects, based on support vector machines (SVMs). Specifically, acceleration and ventilation measured by a wearable multisensor device on 50 test subjects performing 13 types of activities of varying intensities are analyzed, from which activity type and energy expenditure are derived. The results show that the method correctly recognized the 13 activity types 88.1% of the time, which is 12.3% higher than using a hip accelerometer alone. Also, the method predicted energy expenditure with a root mean square error of 0.42 METs, 22.2% lower than using a hip accelerometer alone. Furthermore, the fusion method was effective in reducing the subject-to-subject variability (standard deviation of recognition accuracies across subjects) in activity recognition, especially when data from the ventilation sensor were added to the fusion model. These results demonstrate that the multisensor fusion technique presented is more effective in identifying activity type and energy expenditure than the traditional accelerometer-alone-based methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2011.2178070

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Liu, S., Gao, R. X., John, D., Staudenmayer, J. W., & Freedson, P. S.
Venue
IEEE Transactions on Biomedical Engineering
Published
2012-03
Volume
59
Issue
3
Pages
687-696
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2018608640
Cited by
147
References
5
FWCI
8.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.