Multisensor Data Fusion for Physical Activity Assessment
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents a sensor fusion method for assessing physical activity (PA) of human subjects, based on support vector machines (SVMs). Specifically, acceleration and ventilation measured by a wearable multisensor device on 50 test subjects performing 13 types of activities of varying intensities are analyzed, from which activity type and energy expenditure are derived. The results show that the method correctly recognized the 13 activity types 88.1% of the time, which is 12.3% higher than using a hip accelerometer alone. Also, the method predicted energy expenditure with a root mean square error of 0.42 METs, 22.2% lower than using a hip accelerometer alone. Furthermore, the fusion method was effective in reducing the subject-to-subject variability (standard deviation of recognition accuracies across subjects) in activity recognition, especially when data from the ventilation sensor were added to the fusion model. These results demonstrate that the multisensor fusion technique presented is more effective in identifying activity type and energy expenditure than the traditional accelerometer-alone-based methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
Tapia, E. M., Intille, S. S., Haskell, W., Larson, K., Wright, J., King, A., & Friedman, R. (2007) · 2007 11th IEEE International Symposium on Wearable Computers · doi:10.1109/iswc.2007.4373774 · Cited by 458 · cited 4×
“celerometers at different locations on the body [8]–[12] or combining accelerometers with other types of sensors, such as physiological sensors or GPS [13]–[15], to improve prediction accuracy.”
BackgroundMethodInfluentialFeature Selection and Activity Recognition from Wearable Sensors
Pirttikangas, S., Fujinami, K., & Nakajima, T. (2006) · Lecture Notes in Computer Science · doi:10.1007/11890348_39 · Cited by 229
Accelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174 · cited 1×
“Further details of the basketball and tennis protocols are provided in [28].”
BackgroundSelf-citation
Cited by
Multi-sensor fusion in body sensor networks: State-of-the-art and research challenges
Gravina, R., Alinia, P., Ghasemzadeh, H., & Fortino, G. (2017) · Information Fusion · doi:10.1016/j.inffus.2016.09.005 · Cited by 899
A survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
Advanced internet of things for personalised healthcare systems: A survey
Qi, J., Yang, P., Min, G., Amft, O., Dong, F., & Xu, L. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.018 · Cited by 406
Wearables and the Internet of Things (IoT), Applications, Opportunities, and Challenges: A Survey
John Dian, F., Vahidnia, R., & Rahmati, A. (2020) · IEEE Access · doi:10.1109/access.2020.2986329 · Cited by 386
A multi-sensor data fusion enabled ensemble approach for medical data from body sensor networks
Muzammal, M., Talat, R., Sodhro, A. H., & Pirbhulal, S. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.06.021 · Cited by 311
Metadata
- Authors
- Liu, S., Gao, R. X., John, D., Staudenmayer, J. W., & Freedson, P. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-03
- Volume
- 59
- Issue
- 3
- Pages
- 687-696
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2018608640
- Cited by
- 147
- References
- 5
- FWCI
- 8.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.