Abstract
Oscillometry is a popular technique for automatic estimation of blood pressure (BP). However, most of the oscillometric algorithms rely on empirical coefficients for systolic and diastolic pressure evaluation that may differ in various patient populations, rendering the technique unreliable. A promising complementary technique for automatic estimation of BP, based on the dependence of pulse transit time (PTT) on cuff pressure (CP) (PTT-CP mapping), has been proposed in the literature. However, a theoretical grounding for this technique and a nonparametric BP estimation approach are still missing. In this paper, we propose a novel coefficient-free BP estimation method based on PTT-CP dependence. PTT is mathematically modeled as a function of arterial lumen area under the cuff. It is then analytically shown that PTT-CP mappings computed from various points on the arterial pulses can be used to directly estimate systolic, diastolic, and mean arterial pressure without empirical coefficients. Analytical results are cross-validated with a pilot investigation on ten healthy subjects where 150 simultaneous electrocardiogram and oscillometric BP recordings are analyzed. The results are encouraging whereby the mean absolute errors of the proposed method in estimating systolic and diastolic pressures are 5.31 and 4.51 mmHg, respectively, relative to the Food and Drug Administration approved Omron monitor. Our work thus shows promise toward providing robust and objective BP estimation in a variety of patients and monitoring situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Saeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
Ursino, M., & Cristalli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508540 · Cited by 179 · cited 7×
“5 Hz [21].”
BackgroundMethodInfluentialOscillometric determination of diastolic, mean and systolic blood pressure—A numerical model
Forster, F. K., & Turney, D. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138629 · Cited by 104 · cited 1×
“The most common model for the arterial pressure–area relationship is the exponential model proposed in [24] and [25] and adopted in many research studies on oscillometry [19], [21], [26]–[29], defined as follows:”
MethodTheoretical study on the effect of sensor contact force on pulse transit time
Teng, X.-F., & Zhang, Y.-T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900815 · Cited by 94 · cited 4×
“Therefore, PTT is modeled with two components: the time it takes for the BP pulse wave to arrive from the heart to the brachial artery under the cuff τ0(t) and the time it takes for the BP pulse wave to travel in the brachial artery underneath the cuff τc(t) [16], [29]:”
BackgroundMethodInfluential
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“One reason is that the slope indicates arterial compliance rather than E inc (see Section III-B).”
BackgroundInfluentialDing, X.-R., Zhang, Y.-T., Liu, J., Dai, W.-X., & Tsang, H. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2480679 · Cited by 330
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Self-citationWearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
Metadata
- Authors
- Forouzanfar, M., Ahmad, S., Batkin, I., Dajani, H. R., Groza, V. Z., & Bolic, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-07
- Volume
- 60
- Issue
- 7
- Pages
- 1814-1824
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2110153994
- Cited by
- 80
- References
- 6
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time–Cuff Pressure Dependence. https://app.cochat.ai/papers/10.1109/tbme.2013.2243148
- The paper
- Forouzanfar, M., Ahmad, S., Batkin, I., Dajani, H. R., Groza, V. Z., & Bolic, M. (2013). Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time–Cuff Pressure Dependence. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2013.2243148
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.