Multistep Prediction of Physiological Tremor for Surgical Robotics Applications
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Accurate canceling of physiological tremor is extremely important in robotics-assisted surgical instruments/procedures. The performance of robotics-based hand-held surgical devices degrades in real time due to the presence of phase delay in sensors (hardware) and filtering (software) processes. Effective tremor compensation requires zero-phase lag in filtering process so that the filtered tremor signal can be used to regenerate an opposing motion in real time. Delay as small as 20 ms degrades the performance of human-machine interference. To overcome this phase delay, we employ multistep prediction in this paper. Combined with the existing tremor estimation methods, the procedure improves the overall accuracy by 60% for tremor estimation compared to single-step prediction methods in the presence of phase delay. Experimental results with developed methods for 1-DOF tremor estimation highlight the improvement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is shown50 that a phase-lag as low as 20 ms in the signal filtering part noticeably degrades the system performance.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [50]
In the citing paper
“Moreover, factors such as anxiety and fatigue can modulate the magnitude and the spectrum of the physiological tremor significantly [2].”
From A Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor (2016) · cites this paper as [2]
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,572
Rogers, S. (1996) · Control Engineering Practice · doi:10.1016/0967-0661(96)82838-3 · Cited by 9,278
(1991) · Springer eBooks · doi:10.1007/978-3-7091-2840-4 · Cited by 5,095
(1986) · Signal Processing · doi:10.1016/0165-1684(86)90025-3 · Cited by 1,594
25 years of time series forecasting
De Gooijer, J. G., & Hyndman, R. J. (2006) · International Journal of Forecasting · doi:10.1016/j.ijforecast.2006.01.001 · Cited by 1,587
Discrete-Time Signal Processing
Jenkins, W. K., Jones, D. L., & Hunsinger, B. J. (2002) · Reference Data for Engineers · doi:10.1016/b978-075067291-7/50030-3 · Cited by 536
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508 · cited 1×
“2264546 in the frequency range of 8–12 Hz [11], [12].”
BackgroundEvolution of autonomous and semi‐autonomous robotic surgical systems: a review of the literature
Moustris, G. P., Hiridis, S. C., Deliparaschos, K. M., & Konstantinidis, K. M. (2011) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.408 · Cited by 321
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Self-citationNumerical double integration of acceleration measurements in noise
Thong, Y. K., Woolfson, M. S., Crowe, J. A., Hayes-Gill, B. R., & Jones, D. A. (2004) · Measurement · doi:10.1016/j.measurement.2004.04.005 · Cited by 206
Motion Estimation in Beating Heart Surgery
Ortmaier, T., Groger, M., Boehm, D. H., Falk, V., & Hirzinger, G. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.855716 · Cited by 187
Multistep-Ahead Time Series Prediction
Cheng, H., Tan, P.-N., Gao, J., & Scripps, J. (2006) · Lecture Notes in Computer Science · doi:10.1007/11731139_89 · Cited by 164
Numerical integration approach to on-line identification of continuous-time systems
Sagara, S., & Zhao, Z. (1990) · Automatica · doi:10.1016/0005-1098(90)90158-e · Cited by 145
Tarvainen, M. P., Hiltunen, J. K., Ranta-aho, P. O., & Karjalainen, P. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821029 · Cited by 143
Robotic Motion Compensation for Beating Heart Intracardiac Surgery
Yuen, S. G., Kettler, D. T., Novotny, P. M., Plowes, R. D., & Howe, R. D. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909104065 · Cited by 134
Robotic Compensation of Biological Motion to Enhance Surgical Accuracy
Riviere, C. N., Gangloff, J. A., & de Mathelin, M. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.880722 · Cited by 124
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117 · cited 1×
“After this stage, to separate the tremulous motion from the voluntary motion and to remove the unwanted integration drift and noise [30], a fifth-order Butterworth filter with passband 2–20 Hz is employed as shown in the block diagram.”
MethodSelf-citationEvaluation of a Telerobotic System to Assist Surgeons in Microsurgery
Das, H., Zak, H., Johnson, J., Crouch, J., & Frambach, D. (1999) · Computer Aided Surgery · doi:10.3109/10929089909148155 · Cited by 116
Characteristics of hand tremor time series
Timmer, J., Gantert, C., Deuschl, G., & Honerkamp, J. (1993) · Biological Cybernetics · doi:10.1007/bf00202568 · Cited by 112
Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Veluvolu, K. C., Latt, W. T., & Ang, W. T. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.06.001 · Cited by 65
Self-citationItani, W., Geara, F. B., Haykal, J., et al. (2007) · Radiation Oncology · doi:10.1186/1748-717x-2-1 · Cited by 63
(1992) · doi:10.1201/b12577 · Cited by 57
Optimal digital filtering for tremor suppression
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56 · cited 1×
“Significant amount of research has been conducted on tremor characteristics (pathological and physiological tremors) and its real-time compensation with robotic procedures [6]–[8], [14]–[17].”
BackgroundPathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation
Bo, A. P. L., Poignet, P., & Geny, C. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2091283 · Cited by 53
Drift-Free Position Estimation of Periodic or Quasi-Periodic Motion Using Inertial Sensors
Latt, W. T., Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110605931 · Cited by 53
Self-citationAn Active Hand-Held Instrument for Enhanced Microsurgical Accuracy
Ang, W. T., Riviere, C. N., & Khosla, P. K. (2000) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-40899-4_91 · Cited by 52
Self-citationReal-Time Modeling and Prediction of Physiological Hand Tremor
Zhang, J., & Chu, F. (2006) · Proceedings. (ICASSP '05). IEEE International Conference on Acoustics, Speech, and Signal Processing, 2005. · doi:10.1109/icassp.2005.1416386 · Cited by 43
Compact Sensing Design of a Handheld Active Tremor Compensation Instrument
Latt, W. T., Tan, U.-X., Shee, C. Y., Riviere, C. N., & Ang, W. T. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2030980 · Cited by 40
Self-citationA review of k-step-ahead predictors
Favier, G., & Dubois, D. (1990) · Automatica · doi:10.1016/0005-1098(90)90159-f · Cited by 34
Su, E. L. M., Latt, W. T., Ang, W. T., Lim, T. C., Teo, C. L., & Burdet, E. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333665 · Cited by 26
Self-citationOnline pathological tremor characterization using extended Kalman filtering
Bó, A. P. L., Poignet, P., Widjaja, F., & Ang, W. T. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649516 · Cited by 25
Self-citationReal-time prediction of respiratory motion based on a local dynamic model in an augmented space
Hong, S.-M., Jung, B.-H., & Ruan, D. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/016 · Cited by 25
Self-citationThe organization of upper limb physiological tremor
Carignan, B., Daneault, J., & Duval, C. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2080-3 · Cited by 24
Autoregressive modeling of physiological tremor under microsurgical conditions
Becker, B. C., Tummala, H., & Riviere, C. N. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649569 · Cited by 23
de Koste, J. R. V. S., Cuijpers, J. P., de Geest, F., et al. (2007) · Radiation Oncology · doi:10.1186/1748-717x-2-32 · Cited by 17
A micro motion sensing system for micromanipulation tasks
Latt, W. T., Tan, U.-X., Georgiou, A., Sidarta, A., Riviere, C. N., & Ang, W. T. (2011) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.09.009 · Cited by 12
Self-citation
Research works printed but not linked: 2
- elbe, 1985, Tremor
- charles, 1996, Dexterity Enhancement for Surgery
Cited by
First-in-human study of the safety and viability of intraocular robotic surgery
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0248-4 · Cited by 231
Tatinati, S., Veluvolu, K. C., & Ang, W. T. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2381495 · Cited by 77
Self-citationA Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor
Adhikari, K., Tatinati, S., Ang, W. T., Veluvolu, K. C., & Nazarpour, K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2530564 · Cited by 48
Self-citationAtashzar, S. F., Shahbazi, M., Samotus, O., Tavakoli, M., Jog, M. S., & Patel, R. V. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2530632 · Cited by 45
Shahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“It is shown 50 that a phase-lag as low as 20 ms in the signal filtering part noticeably degrades the system performance.”
Background
Metadata
- Authors
- Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T.
- Affiliations
- Kyungpook National University (KR)
- Nanyang Technological University (SG)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-11
- Volume
- 60
- Issue
- 11
- Pages
- 3074-3082
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2091990540
- Cited by
- 51
- References
- 38
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 6 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 6 · 2015: 2 · 2014: 5 · 2013: 1
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- physiological tremor, tremor compensation, multi-step forecasting, phase lag, sensor delay, zero-phase filtering, human-machine interaction
- MeSH terms
- Algorithms, Fourier Analysis, Hand, Humans, Robotics, Task Performance and Analysis, Tremor, Models, Statistical, Surgery, Computer-Assisted, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.