Noninvasive Imaging of the High Frequency Brain Activity in Focal Epilepsy Patients
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
High-frequency (HF) activity represents a potential biomarker of the epileptogenic zone in epilepsy patients, the removal of which is considered to be crucial for seizure-free surgical outcome. We proposed a high frequency source imaging (HFSI) approach to noninvasively image the brain sources of the scalp-recorded HF EEG activity. Both computer simulation and clinical patient data analysis were performed to investigate the feasibility of using the HFSI approach to image the sources of HF activity from noninvasive scalp EEG recordings. The HF activity was identified from high-density scalp recordings after high-pass filtering the EEG data and the EEG segments with HF activity were concatenated together to form repetitive HF activity. Independent component analysis was utilized to extract the components corresponding to the HF activity. Noninvasive EEG source imaging using realistic geometric boundary element head modeling was then applied to image the sources of the pathological HF brain activity. Five medically intractable focal epilepsy patients were studied and the estimated sources were found to be concordant with the surgical resection or intracranial recordings of the patients. The present study demonstrates, for the first time, that source imaging from the scalp HF activity could help to localize the seizure onset zone and provide a novel noninvasive way of studying the epileptic brain in humans. This study also indicates the potential application of studying HF activity in the presurgical planning of medically intractable epilepsy patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“utilized to probe the brain electrical sources from noninvasive recordings [30], [40], [59]–[62].”
MethodDynamic Statistical Parametric Mapping
Dale, A. M., Liu, A. K., Fischl, B. R., Buckner, R. L., Belliveau, J. W., Lewine, J. D., & Halgren, E. (2000) · Neuron · doi:10.1016/s0896-6273(00)81138-1 · Cited by 1,787
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282 · cited 1×
“However in the close-loop responsive cortical stimulation [2], localizing the epileptogenic zone is important for guiding the implantation of brain stimulation leads.”
BackgroundRealistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 2×
“and the transfer matrix is calculated from the boundary element method (BEM) head model [20], [46].”
MethodEpileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Babiloni, F., Cincotti, F., Babiloni, C., Carducci, F., Mattia, D., Astolfi, L., Basilisco, A., Rossini, P. M., Ding, L., Ni, Y., et al. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.036 · Cited by 412 · cited 1×
“and fMRI could achieve improved performance by integrating the high temporal resolution of EEG and high spatial resolution of fMRI [48], [67]–[71].”
BackgroundSelf-citationSource localization using recursively applied and projected (RAP) MUSIC
Mosher, J. C., & Leahy, R. M. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.740118 · Cited by 398
Electric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its Accuracy
He, B., Musha, T., Okamoto, Y., Homma, S., Nakajima, Y., & Sato, T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326056 · Cited by 334 · cited 3×
“and the transfer matrix is calculated from the boundary element method (BEM) head model [20], [46].”
MethodSelf-citationElectrophysiological Imaging of Brain Activity and Connectivity—Challenges and Opportunities
He, B., Yang, L., Wilke, C., & Yuan, H. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2139210 · Cited by 300
Self-citationeConnectome: A MATLAB toolbox for mapping and imaging of brain functional connectivity
He, B., Dai, Y., Astolfi, L., Babiloni, F., Yuan, H., & Yang, L. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.11.015 · Cited by 229
Self-citationIctal source analysis: Localization and imaging of causal interactions in humans
Ding, L., Worrell, G. A., Lagerlund, T. D., & He, B. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.042 · Cited by 183
Self-citationTracking the Time-Varying Cortical Connectivity Patterns by Adaptive Multivariate Estimators
Astolfi, L., Cincotti, F., Mattia, D., De Vico Fallani, F., Tocci, A., Colosimo, A., Salinari, S., Marciani, M. G., Hesse, W., Witte, H., et al. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.905419 · Cited by 179
Multimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
Self-citationWilke, C., Ding, L., & He, B. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919885 · Cited by 159
Self-citationfMRI–EEG integrated cortical source imaging by use of time-variant spatial constraints
Liu, Z., & He, B. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.003 · Cited by 103
Self-citationLu, Y., Yang, L., Worrell, G. A., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.007 · Cited by 98 · cited 2×
“Studies have shown that the source localization accuracy could be improved by utilizing the dense-array EEG recording system [23], [30].”
BackgroundMethodSelf-citationDynamic imaging of ictal oscillations using non-invasive high-resolution EEG
Yang, L., Wilke, C., Brinkmann, B., Worrell, G. A., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.043 · Cited by 93 · cited 2×
“The spatial-temporal EEG activity can be represented by multiple independent components using ICA as [32], [47], [48]”
MethodSelf-citationAn alternative subspace approach to EEG dipole source localization
Xu, X.-L., Xu, B., & He, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/010 · Cited by 73
Self-citationPaired MEG data set source localization using recursively applied and projected (RAP) MUSIC
Ermer, J. J., Mosher, J. C., Huang, M., & Leahy, R. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867959 · Cited by 64
Spectral and spatial shifts of post-ictal slow waves in temporal lobe seizures
Yang, L., Worrell, G. A., Nelson, C., Brinkmann, B., & He, B. (2012) · Brain · doi:10.1093/brain/aws221 · Cited by 42
Self-citationDynamic imaging of seizure activity in pediatric epilepsy patients
Lu, Y., Yang, L., Worrell, G. A., Brinkmann, B., Nelson, C., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.021 · Cited by 32
Self-citationNoninvasive cortical imaging of epileptiform activities from interictal spikes in pediatric patients
Lai, Y., Zhang, X., van Drongelen, W., Korhman, M., Hecox, K., Ni, Y., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.026 · Cited by 22 · cited 2×
“ical brain activity and they have been widely used in research labs and clinical centers to help study functioning brain activity and pathological brain abnormalities [7], [20]–[43].”
MethodSelf-citation
Cited by
Effect of EEG electrode number on epileptic source localization in pediatric patients
Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.038 · Cited by 149
Self-citation(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00006-0 · Cited by 134
“Lu et al. (2014), Kuhnke et al. (2018) confirmed the detection of focal HFO events with high-density EEG and showed that they can be correctly localized with EEG source imaging.”
BackgroundSelf-citationSohrabpour, A., Lu, Y., Worrell, G., & He, B. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.05.064 · Cited by 89
“Lu et al. performed a study to show that source localization based on HFO’s detected in scalp EEG are more accurate than inter-ictal spikes (Lu et al., 2014).”
BackgroundSelf-citationSohrabpour, A., Ye, S., Worrell, G. A., Zhang, W., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616474 · Cited by 59
“These functional connectivity studies add to our knowledge about localization and imaging of epileptogenic networks using various source-imaging techniques alone [28], [51], [91], [99]–[101].”
Self-citation
Metadata
- Authors
- Lu, Y., Worrell, G. A., Zhang, H. C., Yang, L., Brinkmann, B., Nelson, C., & He, B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-06
- Volume
- 61
- Issue
- 6
- Pages
- 1660-1667
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2143948640
- Cited by
- 47
- References
- 22
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.