The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Magnetic Resonance Imaging at Ultrahigh Fields
Open accessAbstract
Since the introduction of 4 T human systems in three academic laboratories circa 1990, rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model systems at 9.4 T have led to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has demonstrated the existence of significant advantages in SNR and biological information content at these ultrahigh fields, as well as the presence of numerous challenges. Primary difference from lower fields is the deviation from the near field regime; at the frequencies corresponding to hydrogen resonance conditions at ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image nonuniformities for a given sample-coil configuration because of interferences. These nonuniformities were considered detrimental to the progress of imaging at high field strengths. However, they are advantageous for parallel imaging for signal reception and parallel transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies, and improvements in instrumentation and imaging methods, ultrahigh fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 2×
“Since its introduction in 1992 [14], [15], [72], fMRI has fueled explosive developments in the investigation of brain function, achieving depiction of functional activity in”
BackgroundTime course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935 · cited 1×
“Since its introduction in 1992 [14], [15], [72], fMRI has fueled explosive developments in the investigation of brain function, achieving depiction of functional activity in”
BackgroundOgawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586 · cited 3×
“reported a 16-fold 2-D acceleration [136], [137].”
MethodSelf-citationSusceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Function in the human connectome: task-fMRI and individual differences in behavior
Barch, D. M., Burgess, G. C., Harms, M. P., Petersen, S. E., Schlaggar, B. L., Corbetta, M., Glasser, M. F., Curtiss, S., Dixit, S., Feldt, C., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.033 · Cited by 1,529
Resting-state fMRI in the human connectome project
Smith, S. M., Beckmann, C. F., Andersson, J., Auerbach, E. J., Bijsterbosch, J., Douaud, G., Duff, E., Feinberg, D. A., Griffanti, L., Harms, M. P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.039 · Cited by 1,502
Self-citationMultiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Sohrabpour, A., Ye, S., Worrell, G. A., Zhang, W., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616474 · Cited by 59
Metadata
- Authors
- Ugurbil, K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-05
- Volume
- 61
- Issue
- 5
- Pages
- 1364-1379
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2153395892
- Cited by
- 171
- References
- 19
- FWCI
- 9.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging at Ultrahigh Fields. https://app.cochat.ai/papers/10.1109/tbme.2014.2313619
- The paper
- Ugurbil, K. (2014). Magnetic Resonance Imaging at Ultrahigh Fields. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2014.2313619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.