Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
We present optical imaging-based methods to measure vital physiological signals, including breathing frequency (BF), exhalation flow rate, heart rate (HR), and pulse transit time (PTT). The breathing pattern tracking was based on the detection of body movement associated with breathing using a differential signal processing approach. A motion-tracking algorithm was implemented to correct random body movements that were unrelated to breathing. The heartbeat pattern was obtained from the color change in selected region of interest (ROI) near the subject's mouth, and the PTT was determined by analyzing pulse patterns at different body parts of the subject. The measured BF, exhaled volume flow rate and HR are consistent with those measured simultaneously with reference technologies (r = 0.98, for HR; r = 0.93, for breathing rate), and the measured PTT difference (30-40 ms between mouth and palm) is comparable to the results obtained with other techniques in the literature. The imaging-based methods are suitable for tracking vital physiological parameters under free-living condition and this is the first demonstration of using noncontact method to obtain PTT difference and exhalation flow rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603 · cited 1×
“Exhalation flow rate is an important physiological parameter and proportional to a subject’s metabolic rate [19].”
BackgroundRemote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719 · cited 3×
“Heart and breathing rates were obtained from the images of faces [10], [11], upper arms [12], and palms [13] recorded with digital cameras, including smartphone cameras [14] and webcams.”
BackgroundMethodResultNon-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486 · cited 2×
“[15], [16] used an independent component analysis (ICA) method that separates a multivariate signal into additive subcomponents by assuming the mutual statistical independence of the non-Gaussian source signals.”
BackgroundMethodPhysiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452 · cited 1×
“These portable devices, when combined with cell phones, tablets or other mobile devices, provide an opportunity to everyone to monitor one’s vital signs anytime and anywhere [3]–[5].”
BackgroundContact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery
Garbey, M., Sun, N., Merla, A., & Pavlidis, I. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891930 · Cited by 402 · cited 1×
“Another optical approach is based on noncontact mode [9].”
BackgroundUtility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366 · cited 1×
“Despite the attractive features of imaging-based noncontact approach, the signals extracted from the images contain noise from various sources [18].”
BackgroundVELOCITY OF TRANSMISSION OF THE PULSE-WAVE
Bramwell, J. C., & Hill, A. V. (1922) · The Lancet · doi:10.1016/s0140-6736(00)95580-6 · Cited by 353 · cited 1×
“Traditionally, PWV has been measured using a galvanometer [22] and ultrasound techniques [23], [24].”
MethodHeart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345 · cited 1×
“Heart and breathing rates were obtained from the images of faces [10], [11], upper arms [12], and palms [13] recorded with digital cameras, including smartphone cameras [14] and webcams.”
MethodValidation of heart rate extraction using video imaging on a built-in camera system of a smartphone
Kwon, S., Kim, H., & Park, K. S. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346392 · Cited by 245 · cited 1×
“Heart and breathing rates were obtained from the images of faces [10], [11], upper arms [12], and palms [13] recorded with digital cameras, including smartphone cameras [14] and webcams.”
MethodThe difference in pulse transit time to the toe and finger measured by photoplethysmography
Nitzan, M., Khanokh, B., & Slovik, Y. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/1/308 · Cited by 218 · cited 1×
“PTT is related to blood pressure as well as pulse wave velocity (PWV), and is an indicator of cardiovascular parameters, such as arterial elasticity and stiffness [20], [21].”
BackgroundRemote Measurements of Heart and Respiration Rates for Telemedicine
Zhao, F., Li, M., Qian, Y., & Tsien, J. Z. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071384 · Cited by 189 · cited 2×
“More recently, a near-IR enhanced camera was used to obtain HR from a subject’s facial area and breathing rate from the subject’s chest area [17].”
BackgroundMethodAge-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
An ultrasound-based method for determining pulse wave velocity in superficial arteries
Rabben, S. I., Stergiopulos, N., Hellevik, L. R., Smiseth, O. A., Slørdahl, S. A., Urheim, S., & Angelsen, B. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.031 · Cited by 176 · cited 2×
“Traditionally, PWV has been measured using a galvanometer [22] and ultrasound techniques [23], [24].”
MethodResultAssessment of pulse wave velocity
Boutouyrie, P., Briet, M. B., Collin, C., Vermeersch, S. J., & Pannier, B. (2008) · Artery Research · doi:10.1016/j.artres.2008.11.002 · Cited by 170 · cited 1×
“PTT is related to blood pressure as well as pulse wave velocity (PWV), and is an indicator of cardiovascular parameters, such as arterial elasticity and stiffness [20], [21].”
BackgroundNoncontact imaging photoplethysmography to effectively access pulse rate variability
Sun, Y., Hu, S., Azorin-Peris, V., Kalawsky, R., & Greenwald, S. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061205 · Cited by 164 · cited 1×
“Heart and breathing rates were obtained from the images of faces [10], [11], upper arms [12], and palms [13] recorded with digital cameras, including smartphone cameras [14] and webcams.”
MethodA noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound
Brands, P. J., Willigers, J. M., Ledoux, L. A. F., Reneman, R. S., & Hoeks, A. P. G. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00126-4 · Cited by 143 · cited 1×
“Traditionally, PWV has been measured using a galvanometer [22] and ultrasound techniques [23], [24].”
MethodWearable health care system for vital signs monitoring
Paradiso, R. (2003) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2003.1222533 · Cited by 109 · cited 1×
“MONITORING vital physiological signals such as heart rate (HR), pulse transit time (PTT), and breathing pattern, are basic requirements in the diagnosis and during the course of treatment of various diseases [1], [2].”
BackgroundAn Ultra Low Power Pulse Oximeter Sensor Based on Compressed Sensing
Baheti, P. K., & Garudadri, H. (2009) · 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.32 · Cited by 96 · cited 1×
“While useful, this approach requires steady physical contact of one’s finger with the PPG devices [7], [8] or the cameras, which makes it impractical for continuous monitoring of the physiological signals under free-living conditions.”
BackgroundFeasibility of Imaging Photoplethysmography
Zheng, J., Hu, S., Chouliaras, V., & Summers, R. (2008) · 2008 International Conference on BioMedical Engineering and Informatics · doi:10.1109/bmei.2008.365 · Cited by 80 · cited 1×
“Heart and breathing rates were obtained from the images of faces [10], [11], upper arms [12], and palms [13] recorded with digital cameras, including smartphone cameras [14] and webcams.”
MethodJago, J. R., & Murray, A. (1988) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/9/4/003 · Cited by 74 · cited 3×
“Recently, PTT was determined by performing simultaneous ECG and PPG [25]–[27].”
MethodResultA Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies
Yu, S., & Cheng, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616900 · Cited by 63 · cited 1×
“MONITORING vital physiological signals such as heart rate (HR), pulse transit time (PTT), and breathing pattern, are basic requirements in the diagnosis and during the course of treatment of various diseases [1], [2].”
BackgroundIncrease in pulse transit time to the foot after epidural anaesthesia treatment
Babchenko, A., Davidson, E. M., Adler, D., Ginosar, Y., Kurz, V., & Nitzan, M. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344874 · Cited by 57 · cited 1×
“[28] used contact pulse oximetry to determine the PTT difference between left index finger and left second toe.”
MethodWearable Intelligent Systems for E-Health
Poon, C. C. Y., Liu, Q., Gao, H., Lin, W.-H., & Zhang, Y. (2011) · Journal of Computing Science and Engineering · doi:10.5626/jcse.2011.5.3.246 · Cited by 54 · cited 1×
“These portable devices, when combined with cell phones, tablets or other mobile devices, provide an opportunity to everyone to monitor one’s vital signs anytime and anywhere [3]–[5].”
BackgroundMeasuring Vital Signs Using Smart Phones
Chandrasekaran, V. (2010) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc33139 · Cited by 17 · cited 1×
“2327024 The first one is optical detection of a person’s finger pressed against the devices or the cameras built in the mobile devices to perform PPG [6].”
Feasibility of monitoring vascular ageing by multi-site photoplethysmography
Maria, C. D., Sharkey, E., Klinge, A., Zheng, D., Murray, A., O’Sullivan, J. J., & Allen, J. (2012) · doi:10.25405/ncl.34197837 · Cited by 15
Pulse oximetry and PPG measurements in plastic surgery
Pickett, J. A., Amoroso, P., Nield, D. V., & Jones, D. P. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.758831 · Cited by 12 · cited 1×
“While useful, this approach requires steady physical contact of one’s finger with the PPG devices [7], [8] or the cameras, which makes it impractical for continuous monitoring of the physiological signals under free-living conditions.”
Background
Cited by
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2879706 · Cited by 227
“transit time/pulse wave velocity [131], blood pressure [4], as well as systolic and diastolic peaks can also be measured by using rPPG [132].”
MethodEfficientPhys: Enabling Simple, Fast and Accurate Camera-Based Cardiac Measurement
Liu, X., Hill, B., Jiang, Z., Patel, S., & McDuff, D. (2023) · 2023 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV) · doi:10.1109/wacv56688.2023.00498 · Cited by 193
“From this, heart rate [32,35], respiration rate [25] and pulse transit times [28] can be derived.”
BackgroundCamera Measurement of Physiological Vital Signs
McDuff, D. (2023) · ACM Computing Surveys · doi:10.1145/3558518 · Cited by 159
“Utilizing the spatial measurement opportunities presented by cameras, researchers have shown that non-contact PPG from the face and palm can be used to derive pulse transit time which has then been correlated with blood pressure [61, 132].”
BackgroundAlgorithms for Monitoring Heart Rate and Respiratory Rate From the Video of a User’s Face
Sanyal, S., & Nundy, K. K. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2818687 · Cited by 125
Metadata
- Authors
- Shao, D., Yang, Y., Liu, C., Tsow, F., Yu, H., & Tao, N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-11
- Volume
- 61
- Issue
- 11
- Pages
- 2760-2767
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2020211431
- Cited by
- 183
- References
- 27
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.