Noncontact imaging photoplethysmography to effectively access pulse rate variability
Open accessAbstract
Noncontact imaging photoplethysmography (PPG) can provide physiological assessment at various anatomical locations with no discomfort to the patient. However, most previous imaging PPG (iPPG) systems have been limited by a low sample frequency, which restricts their use clinically, for instance, in the assessment of pulse rate variability (PRV). In the present study, plethysmographic signals are remotely captured via an iPPG system at a rate of 200 fps. The physiological parameters (i.e., heart and respiration rate and PRV) derived from the iPPG datasets yield statistically comparable results to those acquired using a contact PPG sensor, the gold standard. More importantly, we present evidence that the negative influence of initial low sample frequency could be compensated via interpolation to improve the time domain resolution. We thereby provide further strong support for the low-cost webcam-based iPPG technique and, importantly, open up a new avenue for effective noncontact assessment of multiple physiological parameters, with potential applications in the evaluation of cardiac autonomic activity and remote sensing of vital physiological signs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079 · cited 1×
“1 Hz, is mediated by both cardiac vagal and sympathetic nerves.(23,24) Hence, the ratio of the LF and HF represents the sympatho-vagal interaction.”
BackgroundHeart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820
Reduced heart rate variability and mortality risk in an elderly cohort. The Framingham Heart Study
Tsuji, H., Venditti, F. J., Manders, E. S., Evans, J. C., Larson, M. G., Feldman, C. L., & Levy, D. (1994) · Circulation · doi:10.1161/01.cir.90.2.878 · Cited by 1,114
Reliability and validity of scores on The Emergency Severity Index version 3
Tanabe, P., Gimbel, R., Yarnold, P. R., Kyriacou, D. N., & Adams, J. G. (2004) · Academic Emergency Medicine · doi:10.1197/j.aem.2003.06.013 · Cited by 326 · cited 1×
“Index triage, an adult patient with a HR > 100 bpm is considered tachycardic.(26) In this scenario, a difference of ∼3 bpm (3% error) obtained by our remote iPPG system would most likely be”
BackgroundNitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
The effect of applied sensor contact force on pulse transit time
Teng, X. F., & Zhang, Y. T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/002 · Cited by 53 · cited 1×
“probes to investigate the effect of contact force on the amplitude and timing of the PPG signal.(9,10) It was shown that this force must be carefully controlled to obtain high-quality, clinically”
Background
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Self-citationNon-contact video-based pulse rate measurement on a mobile service robot
Stricker, R., Muller, S., & Gross, H.-M. (2014) · The 23rd IEEE International Symposium on Robot and Human Interactive Communication · doi:10.1109/roman.2014.6926392 · Cited by 456
HeartPy: A novel heart rate algorithm for the analysis of noisy signals
van Gent, P., Farah, H., van Nes, N., & van Arem, B. (2019) · Transportation Research Part F: Traffic Psychology and Behaviour · doi:10.1016/j.trf.2019.09.015 · Cited by 234
Metadata
- Authors
- Sun, Y., Hu, S., Azorin-Peris, V., Kalawsky, R., & Greenwald, S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2012-10-30
- Volume
- 18
- Issue
- 6
- Pages
- 061205
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2087351881
- Cited by
- 164
- References
- 10
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noncontact imaging photoplethysmography to effectively access pulse rate variability. https://app.cochat.ai/papers/10.1117/1.jbo.18.6.061205
- The paper
- Sun, Y., Hu, S., Azorin-Peris, V., Kalawsky, R., & Greenwald, S. (2012). Noncontact imaging photoplethysmography to effectively access pulse rate variability. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.18.6.061205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.