Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We present a noncontact method to monitor blood oxygen saturation (SpO2). The method uses a CMOS camera with a trigger control to allow recording of photoplethysmography (PPG) signals alternatively at two particular wavelengths, and determines the SpO2 from the measured ratios of the pulsatile to the nonpulsatile components of the PPG signals at these wavelengths. The signal-to-noise ratio (SNR) of the SpO2 value depends on the choice of the wavelengths. We found that the combination of orange (λ = 611 nm) and near infrared (λ = 880 nm) provides the best SNR for the noncontact video-based detection method. This combination is different from that used in traditional contact-based SpO 2 measurement since the PPG signal strengths and camera quantum efficiencies at these wavelengths are more amenable to SpO2 measurement using a noncontact method. We also conducted a small pilot study to validate the noncontact method over an SpO2 range of 83%-98%. This study results are consistent with those measured using a reference contact SpO2 device ( r = 0.936, ). The presented method is particularly suitable for tracking one's health and wellness at home under free-living conditions, and for those who cannot use traditional contact-based PPG devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452 · cited 3×
“RR can be regarded as nearly linear with respect to SpO2 [12], [14], [22]:”
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427 · cited 1×
“pigmentation on fingers, for whom traditional pulse oximetry may otherwise lead to inaccurate measurements [8].”
Lee, J., Matsumura, K., Yamakoshi, K.-I., Rolfe, P., Tanaka, S., & Yamakoshi, T. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609852 · Cited by 202 · cited 2×
“searchers have found that the PPG signals extracted from the red and blue channels were noisier than those extracted from the green channel [6], [15], [16].”
Cited by
Remote patient monitoring: a comprehensive study
Malasinghe, L. P., Ramzan, N., & Dahal, K. (2019) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-017-0598-x · Cited by 534
New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring
van Gastel, M., Stuijk, S., & de Haan, G. (2016) · Scientific Reports · doi:10.1038/srep38609 · Cited by 253
Human Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“Human breath rate can be measured using characteristics of the inhaled and exhaled air such as its carbon dioxide (CO 2 ), its humidity and temperature. signs detection using breath air-sensing methods.”
Simultaneous monitoring of ballistocardiogram and photoplethysmogram using a camera
Shao, D., Tsow, F., Liu, C., Yang, Y., & Tao, N. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2585109 · Cited by 69
Self-citationThe Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
Baek, H. J., Shin, J., & Cho, J. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/3521738 · Cited by 22
Metadata
- Authors
- Shao, D., Liu, C., Tsow, F., Yang, Y., Du, Z., Iriya, R., Yu, H., & Tao, N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-06
- Volume
- 63
- Issue
- 6
- Pages
- 1091-1098
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2398151908
- Cited by
- 150
- References
- 3
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.