OBJECTIVE: Current clinical biomechanics involves lengthy data acquisition and time-consuming offline analyses with biomechanical models not operating in real-time for man-machine interfacing. We developed a method that enables online analysis of neuromusculoskeletal function in vivo in the intact human. METHODS: We used electromyography (EMG)-driven musculoskeletal modeling to simulate all transformations from muscle excitation onset (EMGs) to mechanical moment production around multiple lower-limb degrees of freedom (DOFs). We developed a calibration algorithm that enables adjusting musculoskeletal model parameters specifically to an individual's anthropometry and force-generating capacity. We incorporated the modeling paradigm into a computationally efficient, generic framework that can be interfaced in real-time with any movement data collection system. RESULTS: The framework demonstrated the ability of computing forces in 13 lower-limb muscle-tendon units and resulting moments about three joint DOFs simultaneously in real-time. Remarkably, it was capable of extrapolating beyond calibration conditions, i.e., predicting accurate joint moments during six unseen tasks and one unseen DOF. CONCLUSION: The proposed framework can dramatically reduce evaluation latency in current clinical biomechanics and open up new avenues for establishing prompt and personalized treatments, as well as for establishing natural interfaces between patients and rehabilitation systems. SIGNIFICANCE: The integration of EMG with numerical modeling will enable simulating realistic neuromuscular strategies in conditions including muscular/orthopedic deficit, which could not be robustly simulated via pure modeling formulations. This will enable translation to clinical settings and development of healthcare technologies including real-time bio-feedback of internal mechanical forces and direct patient-machine interfacing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2017.2704085

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 41

  1. 10.1007/s00221-004-1973-3 · doi:10.1007/s00221-004-1973-3
  2. pope, 2012, Comparison of Scaled vs Ultrasound Based Musculoskeletal Models on Knee Muscle Moments During Single-Leg Squatting
  3. 10.1016/j.jbiomech.2008.03.008 · doi:10.1016/j.jbiomech.2008.03.008
  4. 10.1109/TBME.2012.2208746 · DOI
  5. 10.1016/S0021-9290(03)00152-0 · DOI
  6. b?a?kiewicz, 2013, Muscle force distribution during forward and backward locomotion, Acta Bioeng Biomech, 15, 3
  7. 10.1016/j.jbiomech.2008.07.031 · DOI · Paper page
  8. 10.1152/jn.1998.80.4.1868 · DOI
  9. 10.1016/0021-9290(91)90375-W · DOI · Paper page
  10. 10.1016/S0966-6362(98)00007-1 · doi:10.1016/s0966-6362(98)00007-1
  11. 10.1016/S0021-9290(03)00010-1 · DOI · Paper page
  12. 10.1186/1475-925X-13-37 · DOI
  13. 10.1016/j.compbiomed.2009.09.002 · DOI · Paper page
  14. 10.1371/journal.pone.0052618 · DOI · Paper page
  15. 10.3389/fncom.2013.00079 · DOI
  16. 10.1115/1.4023255 · doi:10.1115/1.4023255
  17. 10.1152/jn.00989.2014 · DOI
  18. 10.1152/jn.2002.87.6.2808 · DOI
  19. 10.1016/j.gaitpost.2006.09.074 · DOI
  20. 10.1109/10.102791 · DOI · Paper page
  21. 10.1016/j.jbiomech.2013.09.005 · doi:10.1016/j.jbiomech.2013.09.005
  22. 10.1016/j.jbiomech.2011.10.040 · DOI
  23. 10.1016/j.jbiomech.2013.06.001 · DOI
  24. 10.1016/j.simpat.2006.09.001 · DOI · Paper page
  25. 10.1016/j.jbiomech.2008.09.035 · DOI
  26. 10.1109/TBME.2007.901024 · DOI · Paper page
  27. 10.1016/j.pbiomolbio.2010.09.006 · DOI
  28. 10.1016/0021-9290(90)90349-8 · DOI · Paper page
  29. 10.1016/0021-9290(81)90035-X · DOI · Paper page
  30. 10.1146/annurev.bioeng.3.1.245 · DOI · Paper page
  31. 10.1115/1.4026428 · DOI
  32. 10.1007/s11044-011-9285-4 · DOI
  33. 10.1016/S0010-4825(01)00024-5 · DOI
  34. 10.1109/TBME.2016.2538296 · DOI · Paper page
  35. 10.1109/TRO.2008.926860 · DOI · Paper page
  36. 10.1249/01.mss.0000176684.24008.6f · DOI · Paper page
  37. 10.1109/TBME.2006.880883 · DOI · Paper page
  38. 10.1002/wsbm.1368 · DOI
  39. 10.1016/j.jbiomech.2015.09.021 · DOI · Paper page
  40. 10.1186/s12984-016-0170-5 · doi:10.1186/s12984-016-0170-5
  41. 10.1109/TBME.2008.2005946 · DOI · Paper page

Cited by

See all 157

Metadata

Authors
Durandau, G., Farina, D., & Sartori, M.
Venue
IEEE Transactions on Biomedical Engineering
Published
2018-03
Volume
65
Issue
3
Pages
556-564
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2612974132
Cited by
157
References
3
FWCI
4.66
Type
journal article
Language
en
Open access
green
Funders
ERC Advanced under Grant DEMOVE (267888)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.