Reducing Sensor Noise in MEG and EEG Recordings Using Oversampled Temporal Projection
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Here, we review the theory of suppression of spatially uncorrelated, sensor-specific noise in electro- and magentoencephalography (EEG and MEG) arrays, and introduce a novel method for suppression. Our method requires only that the signals of interest are spatially oversampled, which is a reasonable assumption for many EEG and MEG systems. METHODS: Our method is based on a leave-one-out procedure using overlapping temporal windows in a mathematical framework to project spatially uncorrelated noise in the temporal domain. RESULTS: This method, termed "oversampled temporal projection" (OTP), has four advantages over existing methods. First, sparse channel-specific artifacts are suppressed while limiting mixing with other channels, whereas existing linear, time-invariant spatial operators can spread such artifacts to other channels with a spatial distribution which can be mistaken for one produced by an electrophysiological source. Second, OTP minimizes distortion of the spatial configuration of the data. During source localization (e.g., dipole fitting), many spatial methods require corresponding modification of the forward model to avoid bias, while OTP does not. Third, noise suppression factors at the sensor level are maintained during source localization, whereas bias compensation removes the denoising benefit for spatial methods that require such compensation. Fourth, OTP uses a time-window duration parameter to control the tradeoff between noise suppression and adaptation to time-varying sensor characteristics. CONCLUSION: OTP efficiently optimizes noise suppression performance while controlling for spatial bias of the signal of interest. SIGNIFICANCE: This is important in applications where sensor noise significantly limits the signal-to-noise ratio, such as high-frequency brain oscillations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 2×
“2734641 fields, respectively, produced by electric currents flowing in the brain [1], [2].”
BackgroundMethodSuppression of Interference and Artifacts by the Signal Space Separation Method
Taulu, S., Kajola, M., & Simola, J. (2004) · Brain Topography · doi:10.1023/b:brat.0000032864.93890.f9 · Cited by 541
Self-citationOkada, Y., Pratt, K., Atwood, C., Mascarenas, A., Reineman, R., Nurminen, J., & Paulson, D. (2006) · Review of Scientific Instruments · doi:10.1063/1.2168672 · Cited by 53 · cited 1×
“netometers [26], and a custom phantom with 6 usable dipoles at 200 nAm.”
Background
Research works printed but not linked: 24
- 10.1007/BF02512476 · DOI · Paper page
- kupers, 2017, Broadband spectral responses in visual cortex revealed by a new MEG denoising algorithm, BioRxiv
- 10.1016/0141-5425(83)90001-8 · doi:10.1016/0141-5425(83)90001-8
- 10.1109/10.668741 · DOI · Paper page
- 10.1007/s11517-013-1069-y · DOI
- 10.1016/j.jneumeth.2007.09.012 · DOI
- 10.1016/j.jneumeth.2016.01.005 · DOI
- 10.1109/10.245606 · DOI · Paper page
- 10.1088/0031-9155/32/1/004 · DOI · Paper page
- 10.1007/BF00681735 · DOI · Paper page
- 10.1111/j.1749-6632.1982.tb50789.x · DOI · Paper page
- 10.1007/978-3-642-33045-2_2 · DOI
- 10.1016/j.clinph.2015.06.008 · DOI
- 10.1109/MCSE.2011.37 · DOI · Paper page
- 10.1002/9783527609956.ch11 · doi:10.1002/9783527609956.ch11
- 10.1016/j.neuroimage.2013.08.070 · DOI · Paper page
- 10.1212/01.wnl.0000344402.20334.81 · DOI · Paper page
- niedermeyer, 2004, Electroencephalography Basic Principles Clinical Applications and Related Fields
- 10.1016/j.neuron.2008.04.020 · DOI
- 10.1007/BF02534144 · DOI · Paper page
- 10.1016/j.jneumeth.2007.06.003 · DOI · Paper page
- 10.3389/fnins.2013.00267 · DOI · Paper page
- 10.1063/1.1935742 · DOI · Paper page
- 10.1155/2011/879716 · DOI · Paper page
Cited by
Linguistic effect on speech perception observed at the brainstem
Zhao, T. C., & Kuhl, P. K. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1800186115 · Cited by 52
“MEG data were first preprocessed using the oversampled temporal projection (OTP) method (48) and the temporally extended spatial-signalseparation (tSSS) method (49, 50) to suppress sensor noise and magnetic interference originating from outside of the MEG dewar.”
MethodInfant brain imaging using magnetoencephalography: Challenges, solutions, and best practices
Clarke, M. D., Bosseler, A. N., Mizrahi, J. C., Peterson, E. R., Larson, E., Meltzoff, A. N., Kuhl, P. K., & Taulu, S. (2022) · Human Brain Mapping · doi:10.1002/hbm.25871 · Cited by 21
Self-citationGoble, G., Hennessy, V., Cheng, T.-H. Z., Rodda, A., Taulu, S., Gordon, R. L., & Zhao, T. C. (2026) · PLOS One · doi:10.1371/journal.pone.0335596
“First, the oversampled temporal projection and temporal signal space separation are used to reduce sensor noise and external interference signals as well as to compensate for effects caused by the infants’ head movements during testing [64–66].”
Self-citation
Metadata
- Authors
- Larson, E., & Taulu, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2018-05
- Volume
- 65
- Issue
- 5
- Pages
- 1002-1013
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2739780474
- Cited by
- 58
- References
- 3
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Funders
- Washington State Life Sciences Discovery Fund
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reducing Sensor Noise in MEG and EEG Recordings Using Oversampled Temporal Projection. https://app.cochat.ai/papers/10.1109/tbme.2017.2734641
- The paper
- Larson, E., & Taulu, S. (2018). Reducing Sensor Noise in MEG and EEG Recordings Using Oversampled Temporal Projection. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2017.2734641
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.