Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To demonstrate the feasibility of everaging impedance plethysmography (IPG) for detection of pulse transit time (PTT) and estimation of blood pressure (BP). METHODS: We first established the relationship between BP, PTT, and arterial impedance (i.e., the IPG observations). The IPG sensor was placed on the wrist while the photoplethysmography sensor was attached to the index finger to measure the PTT. With a cuff-based BP monitoring system placed on the upper arm as a reference, our proposed methodology was evaluated on 15 young, healthy human subjects leveraging handgrip exercises to manipulate BP/PTT and compared to several conventional PTT models to assess the efficacy of PTT/BP detections. RESULTS: The proposed model correlated with BP fairly well with group average correlation coefficients of [Formula: see text] for systolic BP (SBP) and [Formula: see text] for diastolic BP (DBP). In comparison with the other PTT methods, PTT-IPG-based BP estimation provided a lower root-mean-squared-error of [Formula: see text] and [Formula: see text] for SBP and DBP, respectively. CONCLUSION: We conclude that the measurement of arterial impedance via IPG methods is an adequate indicator to estimate BP. The proposed method appears to offer superiority compared to the conventional PTT estimation approaches. SIGNIFICANCE: Using impedance magnitude to estimate PTT offers promise to realize wearable and cuffless BP devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569 · cited 2×
“In addition, a number of investigations showed that the LF component of BP is caused by the SM contraction and relaxation [36], [42].”
BackgroundA Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · cited 9×
“In other words, the difference between SBP and DBP becomes large with increasing distance from the heart [1].”
BackgroundMethodInfluentialPulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418 · cited 6×
“The first model for BP estimation is given by [33]: DBP = MBP0 + 2 γ ln PTT0 PTT − PP0 3 · ( PTT0 PTT )2 (12a) SBP = DBP + PP0 · ( PTT0 PTT )2 (12b) and the second PTT model only estimates SBP through the following expression [8]: SBP = SBP0 − 2 γ PTT − PTT0 PTT0 (13) in which PP stands for pulse pressure, γ is a subj…”
BackgroundResultInfluentialPulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Gao, M., Olivier, N. B., & Mukkamala, R. (2016) · Physiological Reports · doi:10.14814/phy2.12768 · Cited by 86 · cited 2×
“Some PTT-based BP estimations using two or multiple PPG sensors in the peripheral arteries have improved the user comfort [18-20].”
BackgroundResult
Cited by
Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281
“Several studies use alternative cardiac signals for ECG, such as impedance plethysmography (IPG) [99], [100], phonocardiogram (PCG) [101], [102], or ballistocardiogram”
BackgroundWearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200
Self-citationCuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Metadata
- Authors
- Huynh, T. H., Jafari, R., & Chung, W.-Y.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2019-04
- Volume
- 66
- Issue
- 4
- Pages
- 967-976
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2885747298
- Cited by
- 178
- References
- 6
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.