CABA: Continuous Authentication Based on BioAura
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Most computer systems authenticate users only once at the time of initial login, which can lead to security concerns. Continuous authentication has been explored as an approach for alleviating such concerns. Previous methods for continuous authentication primarily use biometrics, e.g., fingerprint and face recognition, or behaviometrics, e.g., key stroke patterns. We describe CABA, a novel continuous authentication system that is inspired by and leverages the emergence of sensors for pervasive and continuous health monitoring. CABA authenticates users based on their BioAura, an ensemble of biomedical signal streams that can be collected continuously and non-invasively using wearable medical devices. While each such signal may not be highly discriminative by itself, we demonstrate that a collection of such signals, along with robust machine learning, can provide high accuracy levels. We demonstrate the feasibility of CABA through analysis of traces from the MIMIC-II dataset. We propose various applications of CABA, and describe how it can be extended to user identification and adaptive access control authorization. Finally, we discuss possible attacks on the proposed scheme and suggest corresponding countermeasures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey of cross-validation procedures for model selection
Arlot, S., & Celisse, A. (2010) · Statistics Surveys · doi:10.1214/09-ss054 · Cited by 3,522 · cited 1×
“cies across observations in a time series define a structure in the data that will be ignored by cross-validation [32].”
BackgroundA Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296 · cited 1×
“, heart rate, blood pressure, and body temperature, have drawn a lot of attention from researchers and begun to be adopted in practice [9], [10].”
BackgroundDhamija, R., Tygar, J. D., & Hearst, M. (2006) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1124772.1124861 · Cited by 1,376 · cited 1×
“, an electronic document that allows a device to exchange information securely using the public key infrastructure [40].”
BackgroundPoisoning Attacks against Support Vector Machines
Biggio, B., Nelson, B., & Laskov, P. (2012) · arXiv · doi:10.48550/arxiv.1206.6389 · Cited by 1,331
Saeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
The Quest to Replace Passwords: A Framework for Comparative Evaluation of Web Authentication Schemes
Bonneau, J., Herley, C., Oorschot, P. C. V., & Stajano, F. (2012) · 2012 IEEE Symposium on Security and Privacy · doi:10.1109/sp.2012.44 · Cited by 1,110 · cited 4×
“First, it is desirable for the system to quickly authenticate a legitimate user and reject an impostor to ensure user convenience [3].”
BackgroundInfluentialResting Heart Rate in Cardiovascular Disease
Fox, K., Borer, J. S., Camm, A. J., Danchin, N., Ferrari, R., Lopez Sendon, J. L., Steg, P. G., Tardif, J.-C., Tavazzi, L., & Tendera, M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.079 · Cited by 1,062 · cited 1×
“, certain heart rate ranges may be correlatedwith cardiovascular disease [53].”
BackgroundMulti-sensor fusion in body sensor networks: State-of-the-art and research challenges
Gravina, R., Alinia, P., Ghasemzadeh, H., & Fortino, G. (2017) · Information Fusion · doi:10.1016/j.inffus.2016.09.005 · Cited by 899 · cited 1×
“, heart rate, blood pressure, and body temperature, have drawn a lot of attention from researchers and begun to be adopted in practice [9], [10].”
BackgroundEgelman, S., Jain, S., Portnoff, R. S., Liao, K., Consolvo, S., & Wagner, D. (2014) · Proceedings of the 2014 ACM SIGSAC Conference on Computer and Communications Security · doi:10.1145/2660267.2660273 · Cited by 134
Cited by
Zero Trust Architecture (ZTA): A Comprehensive Survey
Syed, N. F., Shah, S. W., Shaghaghi, A., Anwar, A., Baig, Z., & Doss, R. (2022) · IEEE Access · doi:10.1109/access.2022.3174679 · Cited by 406
“Many medical signals such as brain activity tracked by Electro-encephalogram (EEG) [39], heart rate monitoring using Electrocardiogram (ECG) [40], electrical activity of muscles monitored by Electromyogram (EMG) [41] and an ensemble of various other medical signals [42] have also been explored.”
BackgroundGoogle Workloads for Consumer Devices: Mitigating Data Movement Bottlenecks
Boroumand, A., Ghose, S., Kim, Y., Ausavarungnirun, R., Shiu, E., Thakur, R., Kim, D., Kuusela, A., Knies, A., Ranganathan, P., et al. (2018) · Proceedings of the Twenty-Third International Conference on Architectural Support for Programming Languages and Operating Systems · doi:10.1145/3173162.3173177 · Cited by 273
DARTS: Deceiving Autonomous Cars with Toxic Signs
Sitawarin, C., Bhagoji, A. N., Mosenia, A., Chiang, M., & Mittal, P. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1802.06430 · Cited by 168
“Out-of-Distribution attacks enable the adversary to start from anywhere in the space of images and do not restrict her to the training/test data. as authentication systems [1, 2], health-care applications [3, 4], and several vehicular services [5–8].”
BackgroundSelf-citationSecurity, Privacy, and Usability in Continuous Authentication: A Survey
Baig, A. F., & Eskeland, S. (2021) · Sensors · doi:10.3390/s21175967 · Cited by 98
A Comprehensive Review on Secure Biometric-Based Continuous Authentication and User Profiling
Ayeswarya, S., & Singh, K. J. (2024) · IEEE Access · doi:10.1109/access.2024.3411783 · Cited by 66
“CABA, a novel Continuous Authentication (CA) system, draws inspiration from and makes use of the proliferation of sensors for all-encompassing and ongoing health tracking [34].”
Background
Metadata
- Authors
- Mosenia, A., Sur-Kolay, S., Raghunathan, A., & Jha, N. K.
- Venue
- IEEE Transactions on Computers
- Published
- 2017-05-01
- Volume
- 66
- Issue
- 5
- Pages
- 759-772
- ISSN
- 0018-9340 (ISSN-L)
- OpenAlex
- W2545603433
- Cited by
- 73
- References
- 9
- FWCI
- 19.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.