Discernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper deals with the discernment of broken magnet and static eccentricity faults in permanent magnet synchronous motors through the stator phase current. Broken magnet and static eccentricity faults exhibit very similar fault patterns in back-electromotive force (emf) and flux spectrums. Therefore, it is essential to separate these faults from each other for a true diagnosis. In this study, stator emf and phase current waveforms are analyzed in detail to identify the discerning components and characterize their dynamic behaviors. Two-dimensional time-stepping finite-element simulations and experimental results show that the fault classification process can be implemented by using fault-dependent in-phase current fault signatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181 · cited 1×
“The phase voltages to detect and classify the demagnetization and eccentricity faults [12] and the zero-sequence component of the phase voltages [13] to detect demagnetization fault are be used in PMSMs.”
MethodA Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151 · cited 1×
“Choi-Williams distribution (CWD) [9], a fault severity index [10], and inverse transform [11] are also suggested to determine magnet defect faults in PMSMs.”
BackgroundUrresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73
Haddad, R. Z., & Strangas, E. G. (2013) · 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645703 · Cited by 46 · cited 1×
“The phase voltages to detect and classify the demagnetization and eccentricity faults [12] and the zero-sequence component of the phase voltages [13] to detect demagnetization fault are be used in PMSMs.”
Method
Research works printed but not linked: 25
- 10.1049/iet-epa.2013.0176 · DOI
- choi, 0, Demagnetization characteristics of permanent magnet synchronous machines, Proc 40th Annu Conf IEEE Ind Electron Soc, 469
- 10.1049/iet-epa.2014.0244 · doi:10.1049/iet-epa.2014.0244
- 10.1109/TPEL.2010.2050496 · DOI · Paper page
- 10.1109/TMAG.2008.2001534 · DOI · Paper page
- 10.1109/TIE.2009.2029577 · DOI · Paper page
- 10.1109/TMAG.2008.2001751 · DOI · Paper page
- 10.1109/TMAG.2006.870936 · DOI · Paper page
- 10.1109/TIA.2012.2191253 · DOI · Paper page
- 10.1109/TEC.2015.2416973 · DOI
- 10.1109/TMAG.2009.2015942 · DOI · Paper page
- rosero, 0, Fault detection by means of wavelet transform in a PMSM under demagnetization, Proc 33rd Annu Conf IEEE Ind Electron Soc, 1149
- 10.1109/PEDSTC.2014.6799448 · DOI
- 10.1109/TEC.2009.2037922 · DOI · Paper page
- 10.1109/DEMPED.2009.5292770 · DOI · Paper page
- 10.1109/TEC.2015.2423315 · doi:10.1109/tec.2015.2423315
- 10.1109/TIE.2010.2066538 · DOI · Paper page
- 10.1109/TEC.2013.2279917 · DOI
- 10.1049/iet-epa.2009.0149 · DOI · Paper page
- 10.1109/TEC.2014.2350336 · DOI
- 10.1109/TEC.2014.2347895 · DOI
- 10.1109/TIE.2008.2007529 · DOI · Paper page
- 10.1109/TPEL.2006.886620 · DOI · Paper page
- 10.1109/TPEL.2011.2176145 · DOI · Paper page
- 10.1109/TIE.2011.2151810 · DOI · Paper page
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“using bearings with off-center bushings [142], [144], [151], [156]-[158], shims mounted in the bearing housing [145] or on the motor shaft [147], [148], by modelling misalignment [159], by moving the rotor relative to the stator [153], [154], [160] or by eccentric shaft housings [152].”
MethodFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Park, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116
A review of current issues of marine current turbine blade fault detection
Xie, T., Wang, T., He, Q., Diallo, D., & Claramunt, C. (2020) · Ocean Engineering · doi:10.1016/j.oceaneng.2020.108194 · Cited by 72
Metadata
- Authors
- Goktas, T., Zafarani, M., & Akin, B.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2016-06
- Volume
- 31
- Issue
- 2
- Pages
- 578-587
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2344193144
- Cited by
- 140
- References
- 4
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.