Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
It has been shown that the sensitivity of FET-based biosensors is highest when the biosensor is biased in the subthreshold regime. Given a substrate contact and a solution electrode, there is a wide range of voltages that bias the sensor this way, and not all of them are optimal; we use simulations to clarify the proper bias point. We also show that screening in the buffer solution is bias dependent, and we describe the origin of this dependence. Furthermore, we show that phenomena in the FET part and screening at the outer surface of the biosensor may have differing optimization criteria in terms of biasing. To make the most of the biosensor, both have to be optimized simultaneously. We show that this may require engineering of the charges at the surface of the biosensor, possibly affecting the choice of receptor molecules, linker molecules, and insulator material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The latter part is simply the transconductance effect of an FET-based transistor; nanoscale biosensors have no advantage in this respect over planar sensors.”
From On the origin of enhanced sensitivity in nanoscale FET-based biosensors (2014) · cites this paper as [11]
In the citing paper
“biosensor sensitivity has been shown to be maximum when the biosensor is operated in the subthreshold regime (11,12).”
From On the origin of enhanced sensitivity in nanoscale FET-based biosensors (2014) · cites this paper as [11]
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809 · cited 1×
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundDevelopment of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134 · cited 1×
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundLabel-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352 · cited 1×
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundSubthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571 · cited 1×
“However, if ΔI is considered as the signal of interest, it has been shown that subthreshold operation maximizes the SNR as well [9], [18], [19].”
BackgroundBunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480 · cited 5×
“I. INTRODUCTION F IELD-EFFECT transistor (FET)-based biosensors havebecome one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundInfluentialSubthreshold slope of thin-film SOI MOSFET's
Colinge, J.-P. (1986) · IEEE Electron Device Letters · doi:10.1109/edl.1986.26359 · Cited by 278 · cited 1×
“The presence of the back insulator in fully depleted (FD) SOI and nanowire structures enables FDSOI-based FETs and sensors to achieve near-ideal SS [16].”
BackgroundPoghossian, A., Cherstvy, A., Ingebrandt, S., Offenhäusser, A., & Schöning, M. J. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.03.083 · Cited by 261 · cited 1×
“This quantity of charge is in the neighborhood of that seen in DNA sensing [23].”
BackgroundSilicon Nanoribbons for Electrical Detection of Biomolecules
Elfström, N., Karlström, A. E., & Linnros, J. (2008) · Nano Letters · doi:10.1021/nl080094r · Cited by 185 · cited 1×
“Reference [14] also demonstrates the benefits of having the channel near the front interface; however, they do not use two gates, and therefore, they cannot achieve a near-ideal SS.”
BackgroundLandheer, D., Aers, G., McKinnon, W. R., Deen, M. J., & Ranuarez, J. C. (2005) · Journal of Applied Physics · doi:10.1063/1.2008354 · Cited by 163 · cited 1×
“However, if ΔI is considered as the signal of interest, it has been shown that subthreshold operation maximizes the SNR as well [9], [18], [19].”
BackgroundNoise considerations in field-effect biosensors
Deen, M. J., Shinwari, M. W., Ranuárez, J. C., & Landheer, D. (2006) · Journal of Applied Physics · doi:10.1063/1.2355542 · Cited by 147 · cited 1×
“However, if ΔI is considered as the signal of interest, it has been shown that subthreshold operation maximizes the SNR as well [9], [18], [19].”
BackgroundMechanism and Optimization of pH Sensing Using SnO2 Nanobelt Field Effect Transistors
Cheng, Y., Xiong, P., Yun, C. S., Strouse, G. F., Zheng, J. P., Yang, R., & Wang, Z. L. (2008) · Nano Letters · doi:10.1021/nl801696b · Cited by 121
Silicon-based nanoelectronic field-effect pH sensor with local gate control
Chen, Y., Wang, X., Erramilli, S., Mohanty, P., & Kalinowski, A. (2006) · Applied Physics Letters · doi:10.1063/1.2392828 · Cited by 120 · cited 1×
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundGong, J. (2010) · Small · doi:10.1002/smll.200902132 · Cited by 87 · cited 2×
“Techniques such as those of [21] and [22] should be used to attract analytes, and σA should be used to maximize sensitivity.”
BackgroundMethodOptimizing the Signal-to-Noise Ratio for Biosensing with Carbon Nanotube Transistors
Heller, I., Männik, J., Lemay, S. G., & Dekker, C. (2009) · Nano Letters · doi:10.1021/nl8031636 · Cited by 86
Device considerations for development of conductance-based biosensors
Lee, K., Nair, P. R., Scott, A., Alam, M. A., & Janes, D. B. (2009) · Journal of Applied Physics · doi:10.1063/1.3116630 · Cited by 65
Quantifying signal changes in nano-wire based biosensors
Vico, L. D., Sørensen, M. H., Iversen, L., Rogers, D. M., Sørensen, B. S., Brandbyge, M., Nygård, J., Martinez, K. L., & Jensen, J. H. (2010) · Nanoscale · doi:10.1039/c0nr00442a · Cited by 45 · cited 6×
“A key point not mentioned in [6]–[12] is that an accumulation or inversion”
BackgroundMethodInfluentialScreening model for nanowire surface-charge sensors in liquid
Sørensen, M. H., Mortensen, N. A., & Brandbyge, M. (2007) · Applied Physics Letters · doi:10.1063/1.2779930 · Cited by 43 · cited 2×
“We would like to point out that contrary to [13], the bias that squeezes the most voltage change out of the analytes is not the bias that minimizes the TF screening length in, and maximizes the capacitance of, the FET.”
BackgroundProbing the sensitivity of nanowire-based biosensors using liquid-gating
Lu, M.-P., Hsiao, C.-Y., Lai, W.-T., & Yang, Y. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/42/425505 · Cited by 39
Effect of electrodiffusion current flow on electrostatic screening in aqueous pores
Liu, Y., Sauer, J. R., & Dutton, R. W. (2008) · Journal of Applied Physics · doi:10.1063/1.2906327 · Cited by 33
Substrate bias dependence of subthreshold slopes in fully depleted silicon-on-insulator MOSFET's
Tokunaga, K., & Sturm, J. C. (1991) · IEEE Transactions on Electron Devices · doi:10.1109/16.119018 · Cited by 30 · cited 2×
“Reference [17] clearly describes how to bias such a FET to maximize SS when a back gate is present and why such a bias produces a maximum.”
BackgroundNanoscale thickness double-gated field effect silicon sensors for sensitive pH detection in fluid
Elibol, O. H., Reddy, B., & Bashir, R. (2008) · Applied Physics Letters · doi:10.1063/1.2920776 · Cited by 26 · cited 1×
“Reference [8] studies the effect of two independent gates but does not offer enough”
BackgroundComparison of Methods to Bias Fully Depleted SOI-Based MOSFET Nanoribbon pH Sensors
Chapman, R. A., Fernandes, P. G., Seitz, O., Stiegler, H. J., Wen, H.-C., Chabal, Y. J., & Vogel, E. M. (2011) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2011.2132134 · Cited by 25 · cited 7×
“A key point not mentioned in [6]–[12] is that an accumulation or inversion”
BackgroundMethodInfluentialSubthreshold operation of Schottky barrier silicon nanowire FET for highly sensitive pH sensing
Yoo, S. K., An, J. Y., Yang, S. H., & Lee, J. H. (2010) · Electronics Letters · doi:10.1049/el.2010.2355 · Cited by 6
Controlling Field‐Effect Transistor Biosensor Electrical Characteristics Using Immunosorbent Assay
Vaknin, O., Khamaisi, B., Mizrahi, M., & Ashkenasy, N. (2011) · Electroanalysis · doi:10.1002/elan.201100250 · Cited by 2 · cited 2×
“Techniques such as those of [21] and [22] should be used to attract analytes, and σA should be used to maximize sensitivity.”
BackgroundMethod
Cited by
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Review—Field-Effect Transistor Biosensing: Devices and Clinical Applications
Syu, Y.-C., Hsu, W.-E., & Lin, C.-T. (2018) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0291807jss · Cited by 284
Recent Advances and Progress in Development of the Field Effect Transistor Biosensor: A Review
Wadhera, T., Kakkar, D., Wadhwa, G., & Raj, B. (2019) · Journal of Electronic Materials · doi:10.1007/s11664-019-07705-6 · Cited by 210
On the origin of enhanced sensitivity in nanoscale FET-based biosensors
Shoorideh, K., & Chui, C. O. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315485111 · Cited by 162
“If the FET part of the sensor is made of silicon, and is operated in the subthreshold regime as recommended (11, 12), the Debye length in the FET channel will be on the order of 40 μm, and the relative permittivity will be 11.”
BackgroundMethodSelf-citationBhattacharyya, A., Chanda, M., & De, D. (2019) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2019.2928850 · Cited by 155
“Here, the subthreshold (VT ) regime has been chosen as the sensitivity becomes optimum [10] in the sub-VT regime.”
Background
Metadata
- Authors
- Shoorideh, K., & Chui, C. O.
- Affiliations
- University of California, Los Angeles (US)
- ORCID
- Chui, Chi On
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2012-11
- Volume
- 59
- Issue
- 11
- Pages
- 3104-3110
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W1998029762
- Cited by
- 65
- References
- 24
- Citations by year
- 2025: 4 · 2024: 10 · 2023: 4 · 2022: 8 · 2021: 6 · 2020: 4 · 2019: 8 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 3 · 2014: 6 · 2013: 2
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Electron Devices (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- field-effect transistor biosensors, biosensor sensitivity, ionic screening, surface charge engineering, substrate contact, receptors, linkers, insulator materials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.