CoChat

Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering

Shoorideh, Kaveh, Chui, Chi On · 2012 · IEEE Transactions on Electron Devices

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

It has been shown that the sensitivity of FET-based biosensors is highest when the biosensor is biased in the subthreshold regime. Given a substrate contact and a solution electrode, there is a wide range of voltages that bias the sensor this way, and not all of them are optimal; we use simulations to clarify the proper bias point. We also show that screening in the buffer solution is bias dependent, and we describe the origin of this dependence. Furthermore, we show that phenomena in the FET part and screening at the outer surface of the biosensor may have differing optimization criteria in terms of biasing. To make the most of the biosensor, both have to be optimized simultaneously. We show that this may require engineering of the charges at the surface of the biosensor, possibly affecting the choice of receptor molecules, linker molecules, and insulator material.

Overview

Integrity signals

Registry

Crossref · 10.1109/ted.2012.2214221

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 68

Metadata

Authors
Shoorideh, K., & Chui, C. O.
Affiliations
University of California, Los Angeles (US)
Venue
IEEE Transactions on Electron Devices
Published
2012-11
Volume
59
Issue
11
Pages
3104-3110
ISSN
  • 0018-9383 (ISSN-L)
  • 1557-9646
OpenAlex
W1998029762
Cited by
65
References
24
Citations by year
2025: 4 · 2024: 10 · 2023: 4 · 2022: 8 · 2021: 6 · 2020: 4 · 2019: 8 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 3 · 2014: 6 · 2013: 2
FWCI
2.38
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Electron Devices (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
field-effect transistor biosensors, biosensor sensitivity, ionic screening, surface charge engineering, substrate contact, receptors, linkers, insulator materials

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.