Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
It has been shown that the sensitivity of FET-based biosensors is highest when the biosensor is biased in the subthreshold regime. Given a substrate contact and a solution electrode, there is a wide range of voltages that bias the sensor this way, and not all of them are optimal; we use simulations to clarify the proper bias point. We also show that screening in the buffer solution is bias dependent, and we describe the origin of this dependence. Furthermore, we show that phenomena in the FET part and screening at the outer surface of the biosensor may have differing optimization criteria in terms of biasing. To make the most of the biosensor, both have to be optimized simultaneously. We show that this may require engineering of the charges at the surface of the biosensor, possibly affecting the choice of receptor molecules, linker molecules, and insulator material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The latter part is simply the transconductance effect of an FET-based transistor; nanoscale biosensors have no advantage in this respect over planar sensors.”
From On the origin of enhanced sensitivity in nanoscale FET-based biosensors (2014) · cites this paper as [11]
In the citing paper
“biosensor sensitivity has been shown to be maximum when the biosensor is operated in the subthreshold regime (11,12).”
From On the origin of enhanced sensitivity in nanoscale FET-based biosensors (2014) · cites this paper as [11]
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809 · cited 1×
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundDevelopment of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134 · cited 1×
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundLabel-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352 · cited 1×
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundSubthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571 · cited 1×
“However, if ΔI is considered as the signal of interest, it has been shown that subthreshold operation maximizes the SNR as well [9], [18], [19].”
BackgroundBunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480 · cited 5×
“I. INTRODUCTION F IELD-EFFECT transistor (FET)-based biosensors havebecome one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundInfluentialSubthreshold slope of thin-film SOI MOSFET's
Colinge, J.-P. (1986) · IEEE Electron Device Letters · doi:10.1109/edl.1986.26359 · Cited by 278 · cited 1×
“The presence of the back insulator in fully depleted (FD) SOI and nanowire structures enables FDSOI-based FETs and sensors to achieve near-ideal SS [16].”
BackgroundPoghossian, A., Cherstvy, A., Ingebrandt, S., Offenhäusser, A., & Schöning, M. J. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.03.083 · Cited by 261 · cited 1×
“This quantity of charge is in the neighborhood of that seen in DNA sensing [23].”
BackgroundSilicon Nanoribbons for Electrical Detection of Biomolecules
Elfström, N., Karlström, A. E., & Linnros, J. (2008) · Nano Letters · doi:10.1021/nl080094r · Cited by 185 · cited 1×
“Reference [14] also demonstrates the benefits of having the channel near the front interface; however, they do not use two gates, and therefore, they cannot achieve a near-ideal SS.”
BackgroundLandheer, D., Aers, G., McKinnon, W. R., Deen, M. J., & Ranuarez, J. C. (2005) · Journal of Applied Physics · doi:10.1063/1.2008354 · Cited by 163 · cited 1×
“However, if ΔI is considered as the signal of interest, it has been shown that subthreshold operation maximizes the SNR as well [9], [18], [19].”
BackgroundNoise considerations in field-effect biosensors
Deen, M. J., Shinwari, M. W., Ranuárez, J. C., & Landheer, D. (2006) · Journal of Applied Physics · doi:10.1063/1.2355542 · Cited by 147 · cited 1×
“However, if ΔI is considered as the signal of interest, it has been shown that subthreshold operation maximizes the SNR as well [9], [18], [19].”
Background
Cited by
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Review—Field-Effect Transistor Biosensing: Devices and Clinical Applications
Syu, Y.-C., Hsu, W.-E., & Lin, C.-T. (2018) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0291807jss · Cited by 284
Recent Advances and Progress in Development of the Field Effect Transistor Biosensor: A Review
Wadhera, T., Kakkar, D., Wadhwa, G., & Raj, B. (2019) · Journal of Electronic Materials · doi:10.1007/s11664-019-07705-6 · Cited by 210
On the origin of enhanced sensitivity in nanoscale FET-based biosensors
Shoorideh, K., & Chui, C. O. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315485111 · Cited by 162
“If the FET part of the sensor is made of silicon, and is operated in the subthreshold regime as recommended (11, 12), the Debye length in the FET channel will be on the order of 40 μm, and the relative permittivity will be 11.”
BackgroundMethodSelf-citationBhattacharyya, A., Chanda, M., & De, D. (2019) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2019.2928850 · Cited by 155
“Here, the subthreshold (VT ) regime has been chosen as the sensitivity becomes optimum [10] in the sub-VT regime.”
BackgroundA comprehensive review of FET‐based pH sensors: materials, fabrication technologies, and modeling
Sinha, S., & Pal, T. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100147 · Cited by 118
Electrochemical processes and mechanistic aspects of field-effect sensors for biomolecules
Huang, W., Diallo, A. K., Dailey, J., Besar, K., & Katz, H. E. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00755k · Cited by 112
Dielectrically Modulated Single and Double Gate Tunnel FET Based Biosensors for Enhanced Sensitivity
Talukdar, J., Rawat, G., & Mummaneni, K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3122582 · Cited by 89
Enhanced sensitivity of double gate junctionless transistor architecture for biosensing applications
Parihar, M. S., & Kranti, A. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/14/145201 · Cited by 79
Moudgil, A., Singh, S., Mishra, N., Mishra, P., & Das, S. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900615 · Cited by 71
Kalra, S., Kumar, M. J., & Dhawan, A. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2952333 · Cited by 62
Advancement and Challenges of Biosensing Using Field Effect Transistors
Thriveni, G., & Ghosh, K. (2022) · Biosensors · doi:10.3390/bios12080647 · Cited by 60
“They also optimized the biasing point of the sensor that maximizes sensitivity and also identified Debye-Hückel screening near the oxide/electrode interface that is responsible for bias dependent charge induction in the sensor [93].”
MethodBhattacharyya, I. M., & Shalev, G. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01939 · Cited by 57
Ryu, B., Nam, H., Oh, B.-R., Song, Y., Chen, P., Park, Y., Wan, W., Kurabayashi, K., & Liang, X. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00795 · Cited by 56
Optimization of CMOS-ISFET-Based Biomolecular Sensing: Analysis and Demonstration in DNA Detection
Xu, G., Abbott, J., & Ham, D. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2582845 · Cited by 52
Samota, S., Rani, R., Chakraverty, S., & Kaushik, A. (2021) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2021.106404 · Cited by 46
Sharma, D., Singh, D., Pandey, S. K., Yadav, S., & Kondekar, P. N. (2017) · Superlattices and Microstructures · doi:10.1016/j.spmi.2017.07.035 · Cited by 40
Improved Long-Term Responses of Au-Decorated Si Nanowire FET Sensor for NH3 Detection
Kim, D., Park, C., Choi, W., Shin, S., Jin, B., Baek, R., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2952582 · Cited by 40
Recent Advances in Real-Time Label-Free Detection of Small Molecules
Chieng, A., Wan, Z., & Wang, S. (2024) · Biosensors · doi:10.3390/bios14020080 · Cited by 38
“Thus, impedance biosensors such as FET sensors have grown in popularity for the detection of small molecules due to their detection mechanism, in which the signal is produced by a change in conductance upon binding of charged molecules, allowing high-sensitivity mass independent measurement [17,18].”
BackgroundThin-film transistor arrays for biological sensing systems
Wang, D., Liu, Z., Li, J., Tang, W., Huang, Y., Yu, J., Xu, L., Huang, Q., Song, Y., Wang, L., et al. (2022) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ac7928 · Cited by 25
Power and Sensitivity Management of Carbon Nanotube Transistor Glucose Biosensors
He, J., Cao, X., Liu, H., Liang, Y., Chen, H., Xiao, M., & Zhang, Z. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c17309 · Cited by 25
Georgakopoulou, K., Birbas, A. N., & Spathis, C. (2015) · Journal of Applied Physics · doi:10.1063/1.4914352 · Cited by 25
Bhattacharyya, I. M., Ron, I., Chauhan, A., Pikhay, E., Greental, D., Mizrahi, N., Roizin, Y., & Shalev, G. (2022) · Nanoscale · doi:10.1039/d1nr08468b · Cited by 24
Santermans, S., Schanovsky, F., Gupta, M., Hellings, G., Heyns, M., Roy, W. V., & Martens, K. M. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02285 · Cited by 23
Chowdhury, J., Sarkar, A., Mahapatra, K., & Das, J. K. (2022) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2022.107859 · Cited by 22
Silicon nanowires integrated with CMOS circuits for biosensing application
Jayakumar, G., Asadollahi, A., Hellström, P., Garidis, K., & Östling, M. (2014) · Solid-State Electronics · doi:10.1016/j.sse.2014.04.005 · Cited by 21
“The use of both a fluid and a back gate allows an increased freedom to set the desired bias point of the SiNW compared to only using a back gate [14].”
BackgroundUshiba, S., Nakano, T., Shinagawa, A., Miyakawa, N., Kato, T., Yofu, K., Ono, T., Kanai, Y., Tani, S., Kimura, M., et al. (2023) · ACS Omega · doi:10.1021/acsomega.3c07650 · Cited by 20
Amin, S. I., Gajal, L., & Anand, S. (2018) · Applied Physics A · doi:10.1007/s00339-018-2003-9 · Cited by 20
Zafar, M. S., Dastgeer, G., Kalam, A., Al-Sehemi, A. G., Imran, M., Kim, Y. H., & Chae, H. (2022) · Nanomaterials · doi:10.3390/nano12081305 · Cited by 19
Hsu, W.-E., Chang, Y., & Lin, C. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2927038 · Cited by 19
“At the same time, ISFET sensing mechanisms have also been widely discussed [18]–[20].”
BackgroundRiedel, V., Hinck, S., Peiter, E., & Ruckelshausen, A. (2024) · Electronics · doi:10.3390/electronics13132449 · Cited by 18
“…supply current/voltage of the ISFET sensor o ff ers a be tt er signal-to-noise ratio; a more stable output signal is achieved in comparison to the e ff ects of potential fl uctuations in temperature and therefore a be tt er quality of the output signal 𝑉 (cid:3034)(cid:3046) of the ISFET [29,30].”
BackgroundHighly Sensitive Detection of Urea Using Si Electrolyte-Gated Transistor with Low Power Consumption
Choi, W., Jin, B., Shin, S., Do, J., Son, J., Kim, K., & Lee, J. (2023) · Biosensors · doi:10.3390/bios13050565 · Cited by 14
An Ultrasensitive Silicon-Based Electrolyte-Gated Transistor for the Detection of Peanut Allergens
Kim, D., Jin, B., Kim, S.-A., Choi, W., Shin, S., Park, J., Shim, W., Kim, K., & Lee, J. (2022) · Biosensors · doi:10.3390/bios12010024 · Cited by 13
“The voltage-related sensitivity (SV) and current-related sensitivity (SI) are defined as follows [33,34]: SV = VG,Ab – VG,Ab_PA, (3)”
BackgroundOptimization of the multianalyte determination with biased biosensor response
Baronas, R., Kulys, J. J., Žilinskas, A., Lančinskas, A., & Baronas, D. (2013) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2013.05.003 · Cited by 13
A highly sensitive ISFET using pH-to-current conversion for real-time DNA sequencing
Uzzal, M. M., Zarkesh-Ha, P., Edwards, J. S., Coelho, E., & Rawat, P. (2014) · IEEE International System-on-Chip Conference (SOCC) · doi:10.1109/socc.2014.6948964 · Cited by 11
Surface Charge Modulation and Reduction of Non-Linear Electrolytic Screening in FET-Based Biosensing
Gupta, M., Santermans, S., Hellings, G., Lagae, L., Martens, K. M., & Roy, W. V. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3031469 · Cited by 11
“More recently, Shoorideh and Chui [10] modelled the independent co-optimization of the EDL (low potential drop i.e. low integrated charge density) and of the FET (e.g. low channel charge density in the subthreshold regime) using both a front and back gate, and they suggested a practical way to fine-tune the device by…”
InfluentialVidya, C., Arun, A. P., Patra, S. M., Moses, V., Prashantha, K., & Mudhulu, S. (2025) · Ionics · doi:10.1007/s11581-025-06412-z · Cited by 9
“Additionally, the use of novel nanomaterials and surface modification techniques has further improved the performance and specificity of these sensors [101].”
Survey on Ion Sensitive Field Effect Transistor from the View Point of pH Sensitivity and Drift
Hazarika, C., & Sharma, S. (2017) · Indian Journal of Science and Technology · doi:10.17485/ijst/2017/v10i37/118444 · Cited by 9
Shin, S., Kim, S. W., Choi, W., Do, J., Son, J., Kim, K., Jang, S., & Lee, J. (2024) · Biosensors · doi:10.3390/bios14030124 · Cited by 8
The Physics and Operating Principles of Field-effect Transistor-based Biosensors
Wee, M. F. M. R., Al-Hardan, N. H., Masood, A., Hamid, M. A. A., Jalar, A., & Ahmed, N. M. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781837673421-00001 · Cited by 7
Silicon Nanoribbon FET Sensors : Fabrication, Surface Modification and Microfluidic Integration
Afrasiabi, R. (2016) · DiVA (Digitala Vetenskapliga Arkivet) · Cited by 6
Gupta, A., Sharma, S., & Goswami, R. (2024) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/ad3d07 · Cited by 5
Silicon nanowires integrated in a fully depleted CMOS process for charge based biosensing
Jayakumar, G., Asadollahi, A., Hellström, P., Garidis, K., & Östling, M. (2013) · Joint International EUROSOI Workshop and International Conference on Ultimate Integration on Silicon · doi:10.1109/ulis.2013.6523496 · Cited by 5
Printable transistors for wearable sweat sensing
Rudolph, M., Harris, J., & Ratcliff, E. L. (2019) · Smart Biomedical and Physiological Sensor Technology · doi:10.1117/12.2518890 · Cited by 5
Kim, H. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500506 · Cited by 4
Kim, D., Choi, W., Shin, S., Park, J., Kim, K., Jin, B., & Lee, J. (2021) · IEEE Access · doi:10.1109/access.2021.3136550 · Cited by 4
Biosensors based on two-dimensional materials
Filice, M., Marchal, J. A., & Gamiz, F. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818658-9.00004-1 · Cited by 4
Xiao, K., Wang, H., Xie, H., Li, S. J., Zhao, Z., Cui, Z., Chen, Q., Zhou, P., Liu, F., Xu, Y., et al. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3398086 · Cited by 3
“For an FET-type gas sensor, the current sensitivity ( S I ) is defined as [28] S I = ( I d1 − I d0 ) (cid:14) I d0 (1) where I d0 and I d1 are the drain currents before and after exposure to the target gas, respectively.”
MethodSensitivity analysis of Non-uniform TFET with dual material source-based biosensor
Talukdar, J., Malvika, M., Das, B., & Mummaneni, K. (2022) · IEEE International Symposium on Smart Electronic Systems (iSES) · doi:10.1109/ises54909.2022.00131 · Cited by 3
“reported that the FET based biosensor works properly when biasing is imparted in the sub threshold region [11], S.”
BackgroundSensitivity of Silicon Nanowire Biochemical Sensors
Palestri, P., Mouis, M., Afzalian, A., Selmi, L., Pittino, F., Flandre, D., & Ghibaudo, G. (2014) · Wiley eBooks · doi:10.1002/9781118984772.ch3 · Cited by 2
Macroscopic movement of electrolyte-droplet reveals the characteristics of microscopic ion dynamics
Park, S., Cheon, H., Shin, D.-H., & Park, J. (2025) · Physical Chemistry Chemical Physics · doi:10.1039/d5cp00397k · Cited by 1
Optimization of Bi-Layer Biosensors: Trade-off Between Sensitivity and Enzyme Volume
Baronas, R. (2014) · Cited by 1
Avalanche ISFET Sensing Chip for DNA Sequencing
Uzzal, M. M. (2016) · UNM’s Digital Repository (University of New Mexico) · Cited by 1
Application of Mathematical Modeling to Optimal Design of Biosensors
Baronas, R., Ivanauskas, F., & Kulys, J. J. (2020) · Springer series on chemical sensors and biosensors · doi:10.1007/978-3-030-65505-1_13 · Cited by 1
Understanding and Optimization of Field-Effect Transistor-Based Biological and Chemical Sensors
Shoorideh, K. (2016) · eScholarship (California Digital Library) · Cited by 1
Self-citationA DNA hybridization detection sensor based on photo biased ZnO thin film FET devices
Habibi, M., & Fanaei, M. (2016) · Sensor Review · doi:10.1108/sr-04-2016-0074
Nam, H. (2016) · Deep Blue (University of Michigan)
Advances in Nanotechnology: Influence on Biomolecular Detection Sensors
Arif, K. M., & İçöz, K. (2014) · Pakistan Journal of Scientific & Industrial Research Series A Physical Sciences · doi:10.52763/pjsir.phys.sci.57.2.2014.109.124
Transition metal dichalcogenides as ultrasensitive and high-resolution biosensing nodes
Liang, X. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818386-1.00004-7
On nonlinearity in field-effect transistor-based binding assay response
Gao, W., & Chui, C. O. (2022) · Applied Physics Letters · doi:10.1063/5.0072295
Self-citationChiral Sensors Based on Field‐Effect Transistor
Xiao, Y., Liu, B., & Wang, Y. (2023) · Wiley eBooks · doi:10.1002/9783527834266.ch36
Choi, W., Shin, S., Do, J., Son, J., Kim, K., & Lee, J. (2024) · Micromachines · doi:10.3390/mi15050621
“25 The voltage-related response ( R V ) and the current-related response ( R I ) are defined as follows [15,31,32]:”
BackgroundAPartially Gated Regenerative Feedback Device for Ultra-High Sensitivity Biosensing Applications
Kalra, S., Kannan, N., & Kumar, M. J. (2024) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano61778.2024.10628630
“This is because in this regime, the device current depends exponentially on the gate field [8], [9], leading to a more pronounced field gating effect of biomolecular charges.”
BackgroundGhafar‐Zadeh, E., Forouhi, S., & Azadmousavi, T. (2024) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-94-007-0099-4_3
Asma, S., Shyra, N., Kiran, K. M., & Pandey, C. K. (2024) · International Conference on Artificial Intelligence and Signal Processing (AISP) · doi:10.1109/aisp61711.2024.10870690
“[7 ], [8].”
Son, J., Shin, S., Do, J., Kim, K., & Lee, J. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3623641
“All S V , NW values were extracted in the subthreshold regime [43].”
Halima, H. B. (2021) · theses.fr (ABES) · doi:10.70675/f107d1aaz9094z474czaff8z89b2d2cead55
Asymmetric Triple-Channel Schottky Barrier FinFET Biosensor for Cardiac Biomarker DetectionPreprint
P¹, R., Lakshita, K., Virumandi, S., Sharma, P., Tiwari, R., & Kumar, P. (2026) · Research Square · doi:10.21203/rs.3.rs-11230907/v1
Metadata
- Authors
- Shoorideh, K., & Chui, C. O.
- Affiliations
- University of California, Los Angeles (US)
- ORCID
- Chui, Chi On
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2012-11
- Volume
- 59
- Issue
- 11
- Pages
- 3104-3110
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W1998029762
- Cited by
- 65
- References
- 24
- Citations by year
- 2025: 4 · 2024: 10 · 2023: 4 · 2022: 8 · 2021: 6 · 2020: 4 · 2019: 8 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 3 · 2014: 6 · 2013: 2
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Electron Devices (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- field-effect transistor biosensors, biosensor sensitivity, ionic screening, surface charge engineering, substrate contact, receptors, linkers, insulator materials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.