CoChat

GESTO: A Glove for Enhanced Sensing and Touching Based on Inertial and Magnetic Sensors for Hand Tracking and Cutaneous Feedback

Open access
Baldi, Tommaso Lisini, Scheggi, Stefano, Meli, Leonardo, Mohammadi, Mostafa, Prattichizzo, Domenico · 2017 · IEEE Transactions on Human-Machine Systems

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Abstract

The human hand represents a complex fascinating system with highly sensitive sensory capabilities and dexterous grasping and manipulation functionalities. As a consequence, estimating the hand pose and at the same time having the capability to provide haptic feedback in a wearable way may benefit areas such as rehabilitation, human-robot interaction, gaming, and many more. Existing solutions allow us to accurately measure the hand configuration and provide effective force feedback to the user. However, they have limited wearability/portability. In this paper, we present the wearable sensing/actuation system glove for enhanced sensing and touching (GESTO). It is based on inertial and magnetic sensors for hand tracking, coupled with cutaneous devices for the force feedback rendering. Unlike vision-based tracking systems, the sensing glove does not suffer from occlusion problems and lighting conditions. We properly designed the cutaneous devices in order to reduce possible interferences with the magnetic sensors and performed an experimental validation on ten healthy subjects. In order to measure the estimation accuracy of GESTO, we used a high-precision optical tracker. A comparison between using the glove with and without the haptic devices shows that the presence of them does not induce a statistically significant increase in the estimation error. Experimental results revealed the effectiveness of the proposed approach. The accuracy of our system, 3.32° mean estimation error in the worst case, is comparable with the human ability of discriminating finger joint angle.

Overview

Integrity signals

Registry

Crossref · 10.1109/thms.2017.2720667

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Research works printed but not linked: 1

  1. cobos, 2007, Constraints for realistic hand manipulation, Proc Presence, 369

Cited by

See all 96

Metadata

Authors
Baldi, T. L., Scheggi, S., Meli, L., Mohammadi, M., & Prattichizzo, D.
Affiliations
  • University of Siena (IT)
  • University of Twente (NL)
Venue
IEEE Transactions on Human-Machine Systems
Published
2017-12
Volume
47
Issue
6
Pages
1066-1076
ISSN
  • 2168-2291 (ISSN-L)
  • 2168-2305
OpenAlex
W2738073041
Cited by
96
References
48
Citations by year
2026: 6 · 2025: 10 · 2024: 15 · 2023: 11 · 2022: 11 · 2021: 17 · 2020: 11 · 2019: 9 · 2018: 5 · 2017: 1
FWCI
8.79
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Human-Machine Systems (publishedVersion)
  • Use Siena air (University of Siena) (submittedVersion, cc-by)
Funders
  • European Union Seventh Framework Programme (FP7/2007-2013)
  • WEARHAP—WEARable HxAPtics for humans and robots (601165)
Topics
  • Physical Sciences › Computer Science › Human-Computer Interaction › Hand Gesture Recognition Systems
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
hand tracking, cutaneous feedback, haptic feedback, hand pose estimation, wearable haptic device, magnetic interference, finger joint angles, rehabilitation, human-robot interaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.