Interior Permanent-Magnet Synchronous Motors for Adjustable-Speed Drives
The DOI matches its Crossref record.
Abstract
Interior permanent-magnet (IPM) synchronous motors possess special features for adjustable-speed operation which distinguish them from other classes of ac machines. They are robust high powerdensity machines capable of operating at high motor and inverter efficiencies over wide speed ranges, including considerable ranges of constant-power operation. The magnet cost is minimized by the low magnet weight requirements of the IPM design. The impact of the buried-magnet configuration on the motor's electromagnetic characteristics is discussed. The rotor magnetic circuit saliency preferentially increases the quadrature-axis inductance and introduces a reluctance torque term into the IPM motor's torque equation. The electrical excitation requirements for the IPM synchronous motor are also discussed. The control of the sinusoidal phase currents in magnitude and phase angle with respect to the rotor orientation provides a means for achieving smooth responsive torque control. A basic feedforward algorithm for executing this type of current vector torque control is discussed, including the implications of current regulator saturation at high speeds. The key results are illustrated using a combination of simulation and prototype IPM drive measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Morimoto, S., Takeda, Y., Hirasa, T., & Taniguchi, K. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.60058 · Cited by 610
Schiferl, R. F., & Lipo, T. A. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.52682 · Cited by 318
Schiferl, R., & Lipo, T. A. (2003) · Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1988.25037 · Cited by 311
Kim, H., Harke, M. C., & Lorenz, R. D. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.818966 · Cited by 301
A high-performance inverter-fed drive system of an interior permanent magnet synchronous machine
Bose, B. K. (1988) · IEEE Transactions on Industry Applications · doi:10.1109/28.17470 · Cited by 293
Cavallaro, C., DiTommaso, A. O., Miceli, R., Raciti, A., Galluzzo, G. R., & Trapanese, M. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851595 · Cited by 290
Jeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240
IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults
Welchko, B. A., Jahns, T. M., Soong, W. L., & Nagashima, J. M. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811746 · Cited by 210
Self-citationElectrical Propulsion System Design of Chevrolet Bolt Battery Electric Vehicle
Momen, F., Rahman, K., & Son, Y. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2868280 · Cited by 206
“An interior permanent magnet rotor with two layer V magnet pole design has been used for Chevrolet Bolt BEV motor, due to its inherent benefits [1].”
BackgroundMethodPiippo, A., Hinkkanen, M., & Luomi, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911949 · Cited by 201
“references id,ref and iq,ref are calculated according to maximum torque per current control [12].”
MethodBarcaro, M., Bianchi, N., & Magnussen, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2167731 · Cited by 199
Control Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
Qiao, W., Qu, L., & Harley, R. G. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2018914 · Cited by 190
“Among various PMSMs, the interior PMSM (IPMSM) can offer high-efficiency and high-controllability generation by utilizing the reluctance torque, in addition to the magnet torque [ 7 ], and achieve a constant power in a wide speed range by utilizing flux weakening along the d-axis [8]–[10].”
BackgroundPerformance of interior permanent magnet motor drive over wide speed range
Uddin, M. N., Radwan, T. S., & Rahman, M. A. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/60.986441 · Cited by 185
Khan, M., & Rahman, M. A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004662 · Cited by 163
A Practical On-Board SiC MOSFET Condition Monitoring Technique for Aging Detection
Pu, S., Yang, F., Vankayalapati, B. T., Ugur, E., Xu, C., & Akin, B. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2980220 · Cited by 75
Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives
Beng, G. F. H., Zhang, X., & Vilathgamuwa, D. M. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2311126 · Cited by 65
“The drive system is usually operated along the maximum-torque-per-ampere (MTPA) trajectory to maximize the overall efficiency [14].”
Background
Metadata
- Authors
- Jahns, T. M., Kliman, G. B., & Neumann, T. W.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1986-07
- Volume
- IA-22
- Issue
- 4
- Pages
- 738-747
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2168513419
- Cited by
- 939
- References
- 0
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.