Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Interturn stator winding fault is one of the most frequent faults in permanent-magnet synchronous machines (PMSMs). In this paper, we present a new technique for online detection of this fault in PMSMs. It is based on a residual analysis improved by taking into account back-electromotive force waveform estimation, inverter model, and unbalanced inductance matrix. Then, a current residual monitoring block permits to detect the fault and its severity. The simulation and experimental results validate the proposed method and its efficiency.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Bibliographical review on reconfigurable fault-tolerant control systems
Zhang, Y., & Jiang, J. (2008) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2008.03.008 · Cited by 2,652 · cited 1×
“Indeed, for such an application, PM drives should involve fault-tolerant control techniques [1], reconfigurable systems [2], and healthmonitoring methods to avoid severe failures.”
BackgroundHoltz, J., & Quan, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800779 · Cited by 376
Holtz, J., & Quan, J. (2002) · Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248) · doi:10.1109/ias.2001.955988 · Cited by 354
Shamsi-Nejad, M.-A., Nahid-Mobarakeh, B., Pierfederici, S., & Meibody-Tabar, F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918485 · Cited by 160
Self-citationDesign of a Fault-Tolerant Controller Based on Observers for a PMSM Drive
Akrad, A., Hilairet, M., & Diallo, D. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2050756 · Cited by 155
Nahid-Mobarakeh, B., Meibody-Tabar, F., & Sargos, F.-M. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.889826 · Cited by 146
Self-citationNeti, P., & Nandi, S. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2018905 · Cited by 103
A new approach of dead-time compensation for PWM voltage inverters
Lin, J. (2002) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/81.995662 · Cited by 89
On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A. (2007) · 2007 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2007.4342300 · Cited by 63
An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Lee, Y., & Habetler, T. G. (2007) · APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apex.2007.357610 · Cited by 60
Research works printed but not linked: 4
- schaeffer, 1998, Unbalanced induction machine simulation dedicated to condition monitoring, Proc ICEM'98, 414
- didier, 2004, On the modeling of induction motor model including the first space harmonics for diagnostics purposes, Proc ICEM
- alshandoli, 2006, Detection and diagnosis of stator shorted turns fault in three-phase induction motors using instantaneous phase variation, Al-Satil J, 1, 69
- liu, 2006, New permanent magnet synchronous motor modeling approach for fault diagnosis purposes, Proc EMTS
Cited by
Items 101–104 of 104
Fault Signature Sensitivity based on Residues for Interturn Short Circuit Fault in PMSMS
Deponti, M., Boceda, A., Zhao, M., Perini, R., & Foglia, G. M. (2025) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped53223.2025.11154253
Xue, Q., Liu, J., & Chen, N. (2025) · Chinese Control Conference (CCC) · doi:10.23919/ccc64809.2025.11178409
van de Wetering, R. (2013) · Research Repository (Delft University of Technology)
Entropy-Based Sensor Selection Algorithms for Damage Detection in SHM Systems
Tjen, J. (n.d.) · Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila
Metadata
- Authors
- Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F.
- Affiliations
- Groupe de Recherche en Énergie Électrique de Nancy (FR)
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2011-11
- Volume
- 47
- Issue
- 6
- Pages
- 2402-2412
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2122214279
- Cited by
- 92
- References
- 30
- Citations by year
- 2025: 14 · 2024: 5 · 2023: 10 · 2022: 11 · 2021: 3 · 2020: 8 · 2019: 5 · 2018: 3 · 2017: 7 · 2016: 7 · 2015: 11 · 2014: 3 · 2013: 4 · 2012: 1
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- inter-turn short-circuit fault, stator winding faults, permanent magnet synchronous motor, back-EMF estimation, residual analysis, fault detection, inverter modeling, fault severity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.