Real-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Interturn stator winding fault is one of the most frequent faults in permanent-magnet synchronous machines (PMSMs). In this paper, we present a new technique for online detection of this fault in PMSMs. It is based on a residual analysis improved by taking into account back-electromotive force waveform estimation, inverter model, and unbalanced inductance matrix. Then, a current residual monitoring block permits to detect the fault and its severity. The simulation and experimental results validate the proposed method and its efficiency.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Bibliographical review on reconfigurable fault-tolerant control systems
Zhang, Y., & Jiang, J. (2008) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2008.03.008 · Cited by 2,652
Holtz, J., & Quan, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800779 · Cited by 376
Holtz, J., & Quan, J. (2002) · Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248) · doi:10.1109/ias.2001.955988 · Cited by 354
Shamsi-Nejad, M.-A., Nahid-Mobarakeh, B., Pierfederici, S., & Meibody-Tabar, F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918485 · Cited by 160
Self-citationDesign of a Fault-Tolerant Controller Based on Observers for a PMSM Drive
Akrad, A., Hilairet, M., & Diallo, D. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2050756 · Cited by 155
Nahid-Mobarakeh, B., Meibody-Tabar, F., & Sargos, F.-M. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.889826 · Cited by 146
Self-citationNeti, P., & Nandi, S. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2018905 · Cited by 103
A new approach of dead-time compensation for PWM voltage inverters
Lin, J. (2002) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/81.995662 · Cited by 74
On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A. (2007) · 2007 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2007.4342300 · Cited by 63
An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Lee, Y., & Habetler, T. G. (2007) · APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apex.2007.357610 · Cited by 60
(2007) · 2007 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2007.4544200 · Cited by 44
Back-EMF Based Detection of Stator Winding Inter-turn Fault for PM Synchronous Motor Drives
Boileau, T., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2007) · 2007 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2007.4544105 · Cited by 35
Self-citationRobustness study of a model-based technique for mechanical sensorless PMSM
Nahid‐Mobarakeh, B., Meibody‐Tabar, F., & Sargos, F. M. (2002) · PESC record · doi:10.1109/pesc.2001.954219 · Cited by 31
Self-citationOn-line parameter estimation of PMSM in open loop and closed loop
Khov, M., Régnier, J., & Faucher, J. (2009) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2009.4939651 · Cited by 30
Nahid‐Mobarakeh, B., Meibody‐Tabar, F., & Sargos, F. M. (2004) · Conference record · doi:10.1109/ias.2004.1348723 · Cited by 25
Self-citationTorque Ripples Suppression for Six-Phase Induction Motors Under Open Phase Faults
Kianinezhad, R., Nahid‐Mobarakeh, B., Baghli, L., Bétin, F., & Capolino, G. (2006) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2006.348006 · Cited by 23
Self-citationKhatounian, F., Moreau, S., Monmasson, É., et al. (2006) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2006.295594 · Cited by 22
Fault diagnosis in an induction motor by pattern recognition methods
Casimir, R., Boutleux, E., & Clerc, G. (2003) · doi:10.1109/demped.2003.1234589 · Cited by 21
Self-citationInter-turn short circuit fault detection of wound rotor induction machines using Bispectral analysis
Yazidi, A., Henao, H., Capolino, G., Bétin, F., & Capocchi, L. (2010) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2010.5618128 · Cited by 21
Yeh, C., Povinelli, R. J., Mirafzal, B., et al. (2005) · doi:10.1109/icpst.2004.1460120 · Cited by 19
Electromagnetic flux-based condition monitoring for electrical machines
Negrea, M., Jover, P., & Arkkio, A. (2005) · IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2005.4662506 · Cited by 18
Kim, H.-K., Hur, J., Kim, B.-W., & Kang, G.-H. (2010) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2010.5618390 · Cited by 17
A synchronous machine model to analyze internal faults
Muthumuni, D., McLaren, P. G., Dirks, E., et al. (2002) · Conference record · doi:10.1109/ias.2001.955748 · Cited by 16
Monitoring of generator end winding vibrations
Humer, M., Vogel, R., & Kulig, S. T. (2008) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2008.4800058 · Cited by 13
A new concept for online surge testing for the detection of winding insulation deterioration
Grubic, S., Habetler, T. G., & Restrepo, J. A. (2010) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2010.5618067 · Cited by 13
Control strategies for fault tolerant PM drives using series architecture
Shamsinejad, M. A., Nahid‐Mobarakeh, B., Pierfederici, S., et al. (2010) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2010.5729031 · Cited by 8
Self-citationComparative study of two diagnosis methods for induction machine
Ondel, O., Yazidi, A., Boutleux, E., et al. (2005) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2004.1490275 · Cited by 8
Three Phase Induction Motor Faults Detection by Using Radial Basis Function Neural Network
Alla, A. N. A. (2006) · Journal of Applied Sciences · doi:10.3923/jas.2006.2817.2820 · Cited by 7
A decision system to detect failures in induction motors
Casimir, R., Boutleux, E., Clerc, G., et al. (2003) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2002.1176319 · Cited by 3
Self-citationOn-line monitoring of a PMSM drive system by a multiple feedback relay
Balestrino, A., Landi, A., & Sani, L. (2008) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedham.2008.4581185 · Cited by 1
Research works printed but not linked: 4
- schaeffer, 1998, Unbalanced induction machine simulation dedicated to condition monitoring, Proc ICEM'98, 414
- didier, 2004, On the modeling of induction motor model including the first space harmonics for diagnostics purposes, Proc ICEM
- alshandoli, 2006, Detection and diagnosis of stator shorted turns fault in three-phase induction motors using instantaneous phase variation, Al-Satil J, 1, 69
- liu, 2006, New permanent magnet synchronous motor modeling approach for fault diagnosis purposes, Proc EMTS
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [80], an on-line time domain ITSC fault detection method is proposed, which is based on a residual analysis between the estimated stator currents obtained by a healthy model, accounting for BEMF estimation, inverter model and unbalanced inductance matrix and the real currents of the PMSM.”
BackgroundMethodHaje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2743419 · Cited by 98
Self-citationSynchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
“With electrification of transportation vehicles, this problem is currently studied in aeronautical industry where fault detection is considered as one of the most important advantage of electric actuators compared to hydraulic ones [17].”
BackgroundSelf-citationBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Obeid, N. H., Boileau, T., & Nahid-Mobarakeh, B. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2581760 · Cited by 52
Self-citation
Metadata
- Authors
- Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F.
- Affiliations
- Groupe de Recherche en Énergie Électrique de Nancy (FR)
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2011-11
- Volume
- 47
- Issue
- 6
- Pages
- 2402-2412
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2122214279
- Cited by
- 92
- References
- 30
- Citations by year
- 2025: 14 · 2024: 5 · 2023: 10 · 2022: 11 · 2021: 3 · 2020: 8 · 2019: 5 · 2018: 3 · 2017: 7 · 2016: 7 · 2015: 11 · 2014: 3 · 2013: 4 · 2012: 1
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- inter-turn short-circuit fault, stator winding faults, permanent magnet synchronous motor, back-EMF estimation, residual analysis, fault detection, inverter modeling, fault severity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.