Automatic Tuning of Cascaded Controllers for Power Converters Using Eigenvalue Parametric Sensitivities
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Control structures containing cascaded loops are used in several applications for the stand-alone and parallel operation of three-phase power electronic converters. Potential interactions between these cascaded loops and the complex functional dependence between the controller parameters and the system dynamics prevent the effective application of classical tuning methods in the case of converters operating with a low switching frequency. A tuning approach guided by the eigenvalue parametric sensitivities calculated from a linearized model of the converter and its control system is proposed in this paper. The method is implemented in the form of an iterative procedure enforcing the stability of the system and ensuring that the system eigenvalues are moved away from critical locations. Numerical simulations in the time domain are presented to verify the improvement in the dynamic performance of the system when tuned with the presented algorithm compared with a conventional rule-based tuning method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018 · cited 1×
“R1, presented at the 2013 IEEE Energy Conversion Congress and Exposition, Denver, CO, USA, September 16–20, and approved for publication in the IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS by the Industrial Power Converter Committee of the IEEE Industry Applications Society.”
BackgroundLeonhard, W. (1996) · Springer eBooks · doi:10.1007/978-3-642-97646-9 · Cited by 2,488
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097
A new mathematical model and control of a three-phase AC-DC voltage source converter
Blasko, V., & Kaura, V. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.554176 · Cited by 871
Equivalence of Virtual Synchronous Machines and Frequency-Droops for Converter-Based MicroGrids
D’Arco, S., & Suul, J. A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2288000 · Cited by 776
Self-citationVasquez, J. C., Guerrero, J. M., Luna, A., Rodriguez, P., & Teodorescu, R. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2027921 · Cited by 629
Digital Control in Power Electronics
Buso, S., & Mattavelli, P. (2006) · Synthesis lectures on power electronics · doi:10.2200/s00047ed1v01y200609pel002 · Cited by 535
D'Arco, S., & Suul, J. A. (2013) · 2013 IEEE Grenoble Conference · doi:10.1109/ptc.2013.6652456 · Cited by 443
Self-citationDynamic Stability of a Microgrid With an Active Load
Bottrell, N., Prodanovic, M., & Green, T. C. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2241455 · Cited by 416
Some Aspects of Stability in Microgrids
Majumder, R. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2234146 · Cited by 415
Understanding of tuning techniques of converter controllers for VSC-HVDC
Bajracharya, C., Molinas, M., Suul, J. A., & Undeland, T. M. (2008) · Aaltodoc (Aalto University) · Cited by 192
Self-citationDanielsen, S. (2010) · NORA - Norwegian Open Research Archives · Cited by 48
PARTICIPATION FACTORS AND THEIR CONNECTIONS TO RESIDUES AND RELATIVE GAIN ARRAY
Garofalo, F., Iannelli, L., & Vasca, F. (2002) · IFAC Proceedings Volumes · doi:10.3182/20020721-6-es-1901.00182 · Cited by 31
Cited by
Qoria, T., Gruson, F., Colas, F., Denis, G., Prevost, T., & Guillaud, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959085 · Cited by 256
Li, Z., Zang, C., Zeng, P., Yu, H., & Li, S. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2749424 · Cited by 166
“The parameters of the PI controllers are tuned based on the rules proposed in [12].”
BackgroundMethodInfluentialRavanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
Metadata
- Authors
- D'Arco, S., Suul, J. A., & Fosso, O. B.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2015-03
- Volume
- 51
- Issue
- 2
- Pages
- 1743-1753
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2035718078
- Cited by
- 233
- References
- 18
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.