Three-Level Bidirectional Converter for Fuel-Cell/Battery Hybrid Power System
The DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.
Abstract
A novel three-level (3L) bidirectional converter (BDC) is proposed in this paper. Compared with the traditional BDC, the inductor of the 3L BDC can be reduced significantly so that the dynamic response is greatly improved. Hence, the proposed converter is very suitable for fuel-cell/battery hybrid power systems. In addition, the voltage stress on the switch of the proposed converter is only half of the voltage on the high-voltage side, so it is also suitable for high-voltage applications. The operation principle and the implementation of the control circuit are presented in detail. This paper also proposes a novel bidirectional soft-start control strategy for the BDC. A 1-kW prototype converter is built to verify the theoretical analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The bidirectional Buck-Boost converter can be derived from a unidirectional converter by replacing the unidirectional power switches in the traditional topology with bidirectional power switches [41].”
From Bidirectional DC-DC Converter Topologies for Hybrid Energy Storage Systems in Electric Vehicles: A Comprehensive Review (2025) · cites this paper as [41]
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782
Energy-management system for a hybrid electric vehicle, using ultracapacitors and neural networks
Moreno, J., Ortuzar, M. E., & Dixon, J. W. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.870880 · Cited by 748 · cited 1×
“Battery or ultracapacitor is always employed as the secondary energy source [4]–[7].”
BackgroundUltracapacitor-Based Auxiliary Energy System for an Electric Vehicle: Implementation and Evaluation
Ortuzar, M., Moreno, J., & Dixon, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.894713 · Cited by 529 · cited 1×
“The traditional nonisolated two-level (2L) BDC, as shown in Fig. 2, is now widely used [ 6 ], [14].”
MethodHigh-Efficiency DC-DC Converter With High Voltage Gain and Reduced Switch Stress
Wai, R.-J., Lin, C.-Y., Duan, R.-Y., & Chang, Y.-R. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888794 · Cited by 450 · cited 1×
“According to FC category and rating, different UDCs can be employed [20]–[22].”
Control Strategy of Fuel Cell and Supercapacitors Association for a Distributed Generation System
Thounthong, P., Rael, S., & Davat, B. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.896477 · Cited by 355 · cited 1×
“Battery or ultracapacitor is always employed as the secondary energy source [4]–[7].”
BackgroundA Hybrid Fuel Cell Power System
Jin, K., Ruan, X., Yang, M., & Xu, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2008336 · Cited by 331 · cited 1×
“[1]‐ [ 3 ]. This causes more attention to be focused on distributedgeneration power systems and hybrid vehicles.”
BackgroundSelf-citationA bidirectional DC–DC converter for fuel cell electric vehicle driving system
Chiu, H.-J., & Lin, L.-W. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.876863 · Cited by 327 · cited 1×
“When the voltage difference between the dc bus and the battery is large, the isolated BDC should be employed [10]‐[ 13 ].”
BackgroundA bidirectional DC-DC converter topology for low power application
Jain, M., Daniele, M., & Jain, P. K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.849029 · Cited by 256
Fundamental Considerations of Three-Level DC–DC Converters: Topologies, Analyses, and Control
Ruan, X., Li, B., Chen, Q., Tan, S.-C., & Tse, C. K. (2008) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.927218 · Cited by 254 · cited 1×
“Therefore, the 2L buck model can be borrowed [18].”
Self-citation
Cited by
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
Analysis and Implementation of a Novel Bidirectional DC–DC Converter
Yang, L.-S., & Liang, T.-J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2134060 · Cited by 261
“For non-isolated applications, the non-isolated bidirectional dc–dc converters, which include the conventional boost/buck [1], [5], [12], [14], multilevel [4], three-level [ 10 ], sepic/zeta [23], switched capacitor [24], and coupled inductor types [25], are presented.”
BackgroundAnalysis and Implementation of a Non-Isolated Bidirectional DC-DC Converter with High Voltage Gain
Ardi, H., Ajami, A., Kardan, F., & Nikpour, S. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2552139 · Cited by 244
“Nonisolated types of bidirectional converters comprise conventional boost/buck type [26]–[28], multilevel type [29], three-level type [30], switched capacitor type [31], Sepic/Zeta type [32], and coupled inductor types [33]–[35].”
BackgroundZhang, Y., Gao, Y., Zhou, L., & Sumner, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2788436 · Cited by 239
“conductors in the converter in [22] can be reduced by a half compared with that of the conventional converter, due to the”
BackgroundInfluentialHigh-Conversion-Ratio Bidirectional DC–DC Converter With Coupled Inductor
Hsieh, Y.-P., Chen, J.-F., Yang, L.-S., Wu, C.-Y., & Liu, W.-S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244541 · Cited by 206
“For nonisolated applications, nonisolated bidirectional converters, which include the conventional boost/buck type [20]– [24], the soft-switching technique on conventional boost/buck converter [25], three levels [26], multilevel [27], SEPIC/Zeta [28], switched-capacitor bidirectional converter [29], [30], and a couple…”
Metadata
- Authors
- Jin, K., Yang, M., Ruan, X., & Xu, M.
- Affiliations
- Nanjing University of Aeronautics and Astronautics (CN)
- Huazhong University of Science and Technology (CN)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-06
- Volume
- 57
- Issue
- 6
- Pages
- 1976-1986
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2108712887
- Cited by
- 245
- References
- 25
- Citations by year
- 2026: 10 · 2025: 7 · 2024: 10 · 2023: 15 · 2022: 18 · 2021: 16 · 2020: 18 · 2019: 16 · 2018: 13 · 2017: 19 · 2016: 15 · 2015: 23 · 2014: 19 · 2013: 16 · 2012: 12
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- dynamic response, switch voltage stress, high voltage applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.