An Observer-Based Diagnosis Scheme for Single and Simultaneous Open-Switch Faults in Induction Motor Drives
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this paper, the detection and isolation of open-switch faults in induction motor (IM) drives are addressed from a model-based perspective. Residuals are synthesized by using nonlinear observers followed from a directional characterization. First, it is observed that the IM model can be written in a recurrent decoupled structure by taking the stator currents and mechanical velocity as outputs. In this way, residuals can be insensitive to load torque and operating conditions, and simultaneous faults can be addressed. A pulsewidth modulation three-phase inverter is studied as power actuator for the IM. Hence, in order to isolate faults related to the six switching devices, a directional residual evaluation in the -frame is employed. Hence, three residuals are constructed to isolate the faulty switches. The ideas presented in this paper are validated experimentally in a test bench of 1-hp IM under single and simultaneous faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 1×
“By their relevance in automated processes, several research efforts have focused on developing FDI algorithms for these systems [1].”
Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284 · cited 5×
“Recently, in [22], a fault diagnosis strategy is suggested for a multilevel topology using H-bridges based on artificial intelligence.”
BackgroundResultInfluentialFault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228 · cited 1×
“Faults related to IM can be linked to sensors, actuators, and electrical and mechanical parts [2].”
BackgroundSelf-citation
Cited by
A Review on Basic Data-Driven Approaches for Industrial Process Monitoring
Yin, S., Ding, S. X., Xie, X., & Luo, H. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301773 · Cited by 1,716
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
A Review of Fault Detection and Diagnosis for the Traction System in High-Speed Trains
Chen, H., & Jiang, B. (2020) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2019.2897583 · Cited by 413
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“In general, inverter power device failures can be broadly classified as open-circuit faults and short-circuit faults.”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“integral observers are employed [30], [33]–[36].”
BackgroundOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
Model-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212
“Observer-based approaches for single and simultaneous faults were addressed in [23], [24].”
BackgroundEarly Fault Detection Approach With Deep Architectures
Lu, W., Li, Y., Cheng, Y., Meng, D., Liang, B., & Zhou, P. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2800978 · Cited by 195
“model [5], [6], or analyzing the fault frequencies [3], [7]–[9].”
BackgroundGou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465299 · Cited by 191
“In addition, nonlinear observers were applied to detect and isolate the openswitch faults in induction motor drives [12].”
MethodFreire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279383 · Cited by 167
“Different approaches have also been addressed, such as insulated-gate bipolar transistor (IGBT) gate-voltage monitoring [22] or model-based schemes [23], but additional voltage measurements and high computational demand are some disadvantages of these proposals.”
BackgroundBaudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98
Trabelsi, M., Semail, E., & Nguyen, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2719634 · Cited by 61
“Methods based on voltage signals are not considered in this work since they require additional voltage sensors, as addressed in [10]-[11], or observers development, as proposed in [18]-[20].”
BackgroundMethodFault-Diagnosis and Fault-Tolerant-Control in Industrial Processes and Electrical Drives
Orłowska-Kowalska, T., Kowalski, C. T., & Dybkowski, M. (2017) · Studies in Systems, Decision and Control · doi:10.1007/978-3-319-45735-2_5 · Cited by 21
Metadata
- Authors
- Campos-Delgado, D. U., & Espinoza-Trejo, D. R.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-02
- Volume
- 58
- Issue
- 2
- Pages
- 671-679
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2099499423
- Cited by
- 224
- References
- 3
- FWCI
- 21.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.