Simple Online Fault Detecting Scheme for Short-Circuited Turn in a PMSM Through Current Harmonic Monitoring
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
To detect a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor, a simple online fault detecting scheme is presented. The proposed scheme is based on the monitoring of the second-order harmonic components in theq-axis current through harmonic analysis. To verify the effectiveness of the proposed scheme, a test motor which allows an interturn short in the stator winding has been built, and the entire control system has been implemented using the DSP TMS320F28335.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to the measurement problems, usually measured voltage signal has not been taken as the diagnostic signal; reference or estimated stator vector components (in rotor flux oriented frame, d-q), e.g.[38].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“Torque-producing q-axis current component [38], [182] and a ratio between d-and qaxis components [185] have been applied to design a diagnostic method so far;”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“As in the case of most of the diagnostic methods, the proposed method requires the FFT calculation and thus steady-state operation.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“In [38] the component has been used in order to diagnose the ITSC fault.It is proposed to search for the second-order harmonic amplitude variations and compare it to the healthy condition (the FI is the ratio of 2 nd order harmonic amplitudes in faulty and healthy conditions).”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“A lot of interest is paid into interpolating the FI according to the actual operating pointthere is a necessity to know the amplitudes of the 2 nd order isq harmonic for idle and rated torques for different speed values (only high speed operation is taken into account).”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Recent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345492 · Cited by 264
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475698 · Cited by 239
Current monitoring for detecting inter-turn short circuits in induction motors
Stavrou, A., Sedding, H. G., & Penman, J. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.911400 · Cited by 168
Online Model-Based Stator-Fault Detection and Identification in Induction Motors
De Angelo, C. H., Bossio, G. R., Giaccone, S. J., Valla, M. I., Solsona, J. A., & Garcia, G. O. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2012468 · Cited by 166
Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transform
Awadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847964 · Cited by 87
Kim, K.-H., Choi, D.-U., Gu, B.-G., & Jung, I.-S. (2010) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0183 · Cited by 71
Self-citationStator-Interlaminar-Fault Detection Using an External-Flux-Density Sensor
Romary, R., Jelassi, S., & Brudny, J. F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029525 · Cited by 52
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [38] the component has been used in order to diagnose the ITSC fault.”
BackgroundMethodInfluentialEbrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Hang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214
Zafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
“Two types of faults in a PM motor including the ITSC and inverter switch open faults are investigated in [50] and [51].”
BackgroundFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Online Parameter Estimation for Permanent Magnet Synchronous Machines: An Overview
Zhu, Z. Q., Liang, D., & Liu, K. (2021) · IEEE Access · doi:10.1109/access.2021.3072959 · Cited by 194
Hang, J., Zhang, J., Xia, M., Ding, S., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2953269 · Cited by 150
Wang, B., Wang, J., Griffo, A., & Sen, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793188 · Cited by 150
An Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components
Jeong, H., Moon, S., & Kim, S. W. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2677355 · Cited by 141
Stator-Current Spectrum Signature of Healthy Cage Rotor Induction Machines
Joksimovic, G. M., Riger, J., Wolbank, T. M., Peric, N., & Vasak, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2236995 · Cited by 125
Moon, S., Jeong, H., Lee, H., & Kim, S. W. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2726142 · Cited by 123
Current-Residual-Based Stator Interturn Fault Detection in Permanent Magnet Machines
Hu, R., Wang, J., Mills, A. R., Chong, E., & Sun, Z. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2965500 · Cited by 121
ANN based fault diagnosis of permanent magnet synchronous motor under stator winding shorted turn
Moosavi, S. S., Djerdir, A., Ait-Amirat, Y., & Khaburi, D. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.03.024 · Cited by 118
Pietrzak, P., Wolkiewicz, M., & Orłowska-Kowalska, T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3189076 · Cited by 95
Wei, D., Liu, K., Hu, W. J., Peng, X., Chen, Y., & Ding, R. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3167164 · Cited by 92
Nussbaumer, P., Vogelsberger, M. A., & Wolbank, T. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361114 · Cited by 90
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Wang, C., Liu, X., & Chen, Z. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2318207 · Cited by 85
Chen, Z., Liang, D., Jia, S., Yang, L., & Yang, S. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3255249 · Cited by 72
“dq-axis currents or reference voltages [7], [8].”
Huang, W., Du, B., Li, T., Sun, Y., Cheng, Y. Z., & Cui, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3213512 · Cited by 72
Lee, S.-T., & Hur, J. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2614633 · Cited by 69
Wen, H., Teng, Z., Wang, Y., & Hu, X. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2189531 · Cited by 69
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
A review of Permanent Magnet Synchronous Motor fault diagnosis
ZhifuWang, Yang, J., Ye, H., & Zhou, W. (2014) · 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940870 · Cited by 62
Integration of Interturn Fault Diagnosis and Fault-Tolerant Control for PMSM Drive System
Hang, J., Sun, W., Hu, Q., Ren, X., & Ding, S. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3134821 · Cited by 58
Zhang, Y., Liu, G., Zhao, W., Zhou, H., Chen, Q., & Wei, M. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.2991271 · Cited by 58
Early Detection Technique for Stator Winding Inter-Turn Fault in BLDC Motor Using Input Impedance
Park, J.-K., Jeong, C.-L., Lee, S.-T., & Hur, J. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2330067 · Cited by 58
Pietrzak, P., & Wolkiewicz, M. (2021) · Electronics · doi:10.3390/electronics10151786 · Cited by 54
Detection of interturn faults in PMSMs with different winding configurations
Saavedra, H., Urresty, J.-C., Riba, J., & Romeral, L. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.12.059 · Cited by 54
Hang, J., Hu, Q., Sun, W., Ren, X., Ding, S., Huang, Y., & Hua, W. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3167439 · Cited by 53
D-Q Current Signature-Based Faulted Phase Localization for SM-PMAC Machine Drives
Kuruppu, S. S., & Kulatunga, N. A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334652 · Cited by 51
Analysis and Detection of Inter-Turn Short-Circuit Fault Through Extended Self-Commissioning
Yuan, Q., Zafarani, M., Akin, B., & Fedigan, S. E. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626264 · Cited by 51
Li, Y. G., Wang, R., Mao, R., Zhang, Y., Zhu, K., Li, Y., & Zhang, J. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3306437 · Cited by 50
Maraaba, L. S., Al‐Hamouz, Z., Milhem, A. S., & Abido, M. A. (2019) · IEEE Access · doi:10.1109/access.2019.2923746 · Cited by 47
Fault Detection of Permanent Magnet Synchronous Motor Based on Deep Learning Method
Luo, Y., Qiu, J., & Shi, C. (2018) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems.2018.8549129 · Cited by 41
Pietrzak, P., & Wolkiewicz, M. (2021) · Energies · doi:10.3390/en14061630 · Cited by 40
Şahin, İ., & Keysan, O. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.3048071 · Cited by 40
Diagnosis of stator winding short-circuit faults in an interior permanent magnet synchronous machine
He, J., Somogyi, C., Strandt, A., & Demerdash, N. A. O. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953825 · Cited by 39
Leboeuf, N., Boileau, T., Nahid‐Mobarakeh, B., Takorabet, N., Meibody‐Tabar, F., & Clerc, G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2387338 · Cited by 39
Fault Detection and Condition Monitoring of PMSGs in Offshore Wind Turbines
Freire, N. M. A., & Cardoso, A. J. M. (2021) · Machines · doi:10.3390/machines9110260 · Cited by 39
Öner, M. Ü., Şahin, İ., & Keysan, O. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3274052 · Cited by 38
Zeng, C., Huang, S., Yang, Y., & Wu, D. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0865 · Cited by 38
Hang, J., Zhang, J., Cheng, M., & Wang, Z. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6647169 · Cited by 36
“It is successfully used to detect the stator inter-turn [6]-[7], air-gap eccentricity [8]-[9], damaged bearing [10] and demagnetization faults [11].”
MethodChange‐detection algorithm for short‐circuit fault detection in closed‐loop AC drives
Meinguet, F., Semail, E., Kestelyn, X., Mollet, Y., & Gyselinck, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0316 · Cited by 34
“The most common methods reported in the literature are: current-based techniques [8-16], electromotive force- or voltage-based techniques [17-21], power-based techniques [22] and parameter estimation [23, 24].”
MethodHe, Y., Zhang, Y., Xu, M., Wang, X., & Xiong, J. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2907450 · Cited by 34
An MPC-Based Online Interturn Fault Diagnosis Method for Induction Motors With Fault Localization
Jia, Z., Song, W., Ma, C., Zhang, B., & Sun, N. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3386847 · Cited by 34
Model-Based Data Normalization for Data-Driven PMSM Fault Diagnosis
Chen, Z., Liang, D., Jia, S., & Yang, S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3398802 · Cited by 33
Improved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30
Jiang, Y., Ji, B., Zhang, J., Yan, J., & Li, W. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15040165 · Cited by 30
Investigation of Signal Injection Methods for Fault Detection of PMSM Drives
Xu, Z., Zhang, J., & Cheng, M. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3168690 · Cited by 30
Yang, J. P., Zhou, J., Zhou, H., Feng, Y., Song, D., & Dong, M. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3222661 · Cited by 30
Early detection technique for stator winding inter-turn fault in BLDC motor using input impedance
Jeong, C.-L., Lee, S.-T., & Hur, J. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647296 · Cited by 30
Niu, F., Wei, F., Huang, S., Wu, L., Zhang, J., Huang, X., & Fang, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3273897 · Cited by 29
A Review of Robotic Arm Joint Motors and Online Health Monitoring Techniques
Metwly, M. Y., Clark, C. L., He, J., & Xie, B. (2024) · IEEE Access · doi:10.1109/access.2024.3447573 · Cited by 29
Regional protection scheme designed for low-voltage micro-grids
Lin, X., Zhang, R., Tong, N., Li, X., Li, M., & Yang, D. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.07.050 · Cited by 29
Inter-Turn Fault Detection in Stator Winding of PMSM Using Wavelet Transform
Moosavi, S. S., Esmaili, Q., Djerdir, A., & Amirat, Y. A. (2017) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2017.8330891 · Cited by 28
Usman, A., Doiphode, N. T., & Rajpurohit, B. S. (2019) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2019.8883929 · Cited by 26
Xu, Y., Wang, Y., & Zou, J. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3125653 · Cited by 26
Thermal Degradation Phenomena of Polymer Film on Magnet Wire for Electromagnetic Coils
Kavanagh, D. F., Gyftakis, K. N., & McCulloch, M. D. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3040201 · Cited by 26
Fault detection in 3-phase Traction Motor using Artificial Neural Networks
Moosavi, S. S., Djerdir, A., Ait-Amirat, Y., & Khaburi, D. A. (2012) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2012.6243433 · Cited by 25
Short-circuit fault diagnosis in permanent magnet synchronous motors- an overview
Faiz, J., & Exiri, S. A. H. (2015) · International Aegean Conference on Electrical Machines and Power Electronics & International Conference on Optimization of Electrical and Electronic Equipment (ACEMP-OPTIM) · doi:10.1109/optim.2015.7427038 · Cited by 24
Statistic-Based Method to Monitor Belt Transmission Looseness Through Motor Phase Currents
Picot, A., Fournier, E., Régnier, J., TientcheuYamdeu, M., Andrejak, J.-M., & Maussion, P. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2661317 · Cited by 22
Lee, J., Moon, S., Jeong, H., & Kim, S. (2015) · Sensors · doi:10.3390/s151129452 · Cited by 21
Zheng, P., Liu, W., Gao, Y., Tong, C., & Sui, Y. (2025) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2025.00022 · Cited by 21
Fournier, E., Picot, A., Régnier, J., Andrieux, C., Saint-Michel, J., & Maussion, P. (2015) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303699 · Cited by 21
Bahloul, I., Bouzid, M. B. K., Khil, S. K. E., & Champenois, G. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3236898 · Cited by 21
Diagnosis technique for stator winding inter-turn fault in BLDC motor using detection coil
Lee, S.-T., Kim, K., & Hur, J. (2015) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7168191 · Cited by 20
Self-citationCao, J., Sun, X., & Tian, X. (2021) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-201630 · Cited by 20
Guefack, F. L. T., Kiselev, A., & Kuznietsov, A. (2018) · 2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2018.8445403 · Cited by 19
Artificial neural networks based fault detection in 3-Phase PMSM traction motor
Moosavi, S. S., Djerdir, A., Ait-Amirat, Y., & Kkuburi, D. A. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6350089 · Cited by 19
Rule-based fault diagnosis of hall sensors and fault-tolerant control of PMSM
Song, Z., Li, J., Ouyang, M., Gu, J., Feng, X., & Lu, D. (2013) · Chinese Journal of Mechanical Engineering · doi:10.3901/cjme.2013.04.813 · Cited by 19
Reactive Power-Residual-Based Stator Interturn Fault Detection in PMSM Drive
Manala, S., & Seshadrinath, J. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3351627 · Cited by 19
PWM Ripple Currents Based Turn Fault Detection for Multiphase Permanent Magnet Machines
Hu, R., Wang, J., Sen, B., Mills, A. R., Chong, E., & Sun, Z. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2642193 · Cited by 19
Chen, Y., Chen, X., & Shen, Y. (2018) · Energies · doi:10.3390/en11030662 · Cited by 18
Zhang, C., Wang, F., Wang, Z., & Yang, J. (2014) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940913 · Cited by 17
Kiselev, A., Kuznietsov, A., & Leidhold, R. (2017) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2017.7915199 · Cited by 16
Yang, J. W., Dai, Z., & Zhang, Z. (2020) · Microelectronics Reliability · doi:10.1016/j.microrel.2020.113778 · Cited by 16
Xu, Z., Zhang, J., Din, Z., Wu, Y., & Cheng, M. (2023) · Journal of Power Electronics · doi:10.1007/s43236-022-00585-w · Cited by 16
Grouz, F., Sbita, L., & Boussak, M. (2012) · International Conference on Communications, Computing and Control Applications · doi:10.1109/ccca.2012.6417873 · Cited by 15
Interturn Short-Circuit Fault Detection of a Five-Phase Permanent Magnet Synchronous Motor
Yang, Z., & Chen, Y. (2021) · Energies · doi:10.3390/en14020434 · Cited by 15
Jung, W., Yun, S.-H., Lim, Y.-S., Cheong, S., Bae, J., & Park, Y. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968718 · Cited by 15
Safa, H. H., Ebrahimi, M., Zarchi, H. A., & Abshari, M. (2017) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-017-0201-6 · Cited by 15
Chen, Y., Xiaobin, Z., Yang, Y., & Shi, Y. (2019) · Energies · doi:10.3390/en12030510 · Cited by 15
Arianborna, M. H., Faiz, J., Ghods, M., & Bazrafshan, M. A. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12127 · Cited by 14
A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundNiu, F., Xu, M., Zhou, F., Huang, S., Xu, Z., Zhang, L., & Aggarwal, A. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3487628 · Cited by 13
A Review of Fault Diagnosis Methods of Robot Joint Servo System
Wu, H. Q., & Feng, J. (2020) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma49215.2020.9233583 · Cited by 13
Jeong, H., Moon, S., Lee, J., & Kim, S. W. (2016) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2016.7474745 · Cited by 13
Pietrzak, P., & Wolkiewicz, M. (2024) · Power Electronics and Drives · doi:10.2478/pead-2024-0007 · Cited by 12
Yang, J., Dou, M., Dai, Z., Zhao, D., & Zhang, Z. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7468312 · Cited by 12
Zhang, W., Xu, Q., Gao, L., Miao, Y., Cai, H., & Zhao, Y. (2024) · Electrical Engineering · doi:10.1007/s00202-024-02788-9 · Cited by 11
Yang, Y., Chen, Y., & Hao, W. (2020) · IET Electric Power Applications · doi:10.1049/elp2.12011 · Cited by 11
Finite Element Modeling of Stator Winding Faults in Permanent Magnet Synchronous Motor: Part II
Usman, A., Doiphode, N. T., & Rajpurohit, B. S. (2019) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2019.8883937 · Cited by 10
Guo, T., Chang, S., Chen, Z., Huang, H., & Xu, J. (2019) · IEEE Access · doi:10.1109/access.2019.2933881 · Cited by 10
Hsu, H.-Y. M., Lo, T., & Hsieh, M. (2023) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3589 · Cited by 10
Irhoumah, M., Mercier, D., Pusca, R., Lefèvre, É., & Romary, R. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8217417 · Cited by 10
Inter-Turn Short-Circuit Fault Diagnosis and Severity Estimation for Five-Phase PMSM
Huang, Y., Huang, W., Pan, T., & Xu, D. (2025) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2025.00019 · Cited by 10
Suti, A., Rito, G. D., & Galatolo, R. (2022) · Aerospace · doi:10.3390/aerospace9080401 · Cited by 10
Metadata
- Authors
- Kim, K.-H.
- Affiliations
- Seoul National University of Science and Technology (KR)
- Corresponding author
- Kim, Kyeong-Hwa
- ORCID
- Kim, Kyeong-Hwa
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-06
- Volume
- 58
- Issue
- 6
- Pages
- 2565-2568
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2121565094
- Cited by
- 184
- References
- 9
- Citations by year
- 2026: 6 · 2025: 19 · 2024: 19 · 2023: 16 · 2022: 21 · 2021: 18 · 2020: 12 · 2019: 13 · 2018: 9 · 2017: 9 · 2016: 11 · 2015: 8 · 2014: 11 · 2013: 6 · 2012: 5
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- stator winding faults, permanent magnet synchronous motor, real-time fault detection, second harmonic, q-axis current, DSP-based motor control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.