Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Online fault diagnosis plays a crucial role in providing the required fault tolerance to drive systems used in safety-critical applications. Short-circuit faults are among the common faults occurring in electrical machines. This paper presents a review of existing techniques available for online stator interturn fault detection and diagnosis (FDD) in electrical machines. Special attention is given to short-circuit-fault diagnosis in permanent-magnet machines, which are fast replacing traditional machines in a wide variety of applications. Recent techniques that use signals analysis, models, or knowledge-based systems for FDD are reviewed in this paper. Motor current is the most commonly analyzed signal for fault diagnosis. Hence, motor current signature analysis is a topic of elaborate discussion in this paper. Additionally, parametric and finite-element models that were designed to simulate interturn-fault conditions are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 1×
“An exhaustive survey of detection and diagnosis methods of various faults such as stator faults and bearing damage in induction machines has been presented in [4] and [ 5 ].”
BackgroundCurrent Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
Cause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors
Bonnett, A. H., & Soukup, G. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.148460 · Cited by 593
Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
Cause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors
Bonnett, A. K., & Soukup, G. C. (2002) · Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference · doi:10.1109/papcon.1991.239667 · Cited by 489
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361
Increased Efficiency Versus Increased Reliability
Bonnett, A., & Yung, C. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.909802 · Cited by 359
A Survey of Methods for Detection of Stator-Related Faults in Induction Machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900448 · Cited by 301
Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282
Research works printed but not linked: 4
- 10.1109/ICELMACH.2008.4800099 · doi:10.1109/icelmach.2008.4800099
- 10.1109/TIE.2009.2025715 · DOI
- 10.1109/PESC.2001.954450 · doi:10.1109/pesc.2001.954450
- 10.1109/ICIEA.2007.4318852 · doi:10.1109/iciea.2007.4318852
Cited by
From Model, Signal to Knowledge: A Data-Driven Perspective of Fault Detection and Diagnosis
Dai, X., & Gao, Z. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2243743 · Cited by 728
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
A Survey on Wind Turbine Condition Monitoring and Fault Diagnosis—Part I: Components and Subsystems
Qiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422112 · Cited by 533
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Other time-frequency signal analysis methods applied in the diagnostics use a quadratic time-frequency distribution [19], [27], [29], [32].”
BackgroundMethodEbrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Methodology for fault detection in induction motors via sound and vibration signals
Delgado-Arredondo, P. A., Morinigo-Sotelo, D., Osornio-Rios, R. A., Avina-Cervantes, J. G., Rostro-Gonzalez, H., & Romero-Troncoso, R. D. J. (2017) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2016.06.032 · Cited by 266
Zafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
“[15] in 2011, in which the diagnosis and mod-”
BackgroundFeng, G., Lai, C., Mukherjee, K., & Kar, N. C. (2016) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2016.2538180 · Cited by 195
“will induce the winding resistance to increase and rotor flux linkage to decrease, and the magnetic saturation will cause the dq-axis inductances to vary [6]–[10].”
BackgroundFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
“In recent literature [7, 20]–[28], the extraction of fault features from different signals in both induction and PM machines is typically satisfied.”
BackgroundInfluentialDemagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119
“FFT averages the stator phases current in time domain [14];”
BackgroundMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
“Several detection methods were developed to detect and identify turn-to-turn faults in PMSMs [16]–[18].”
MethodSynchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
“An efficient way to improve the availability of a drive is to detect its faults in real time in order to switch to a degraded operating mode under fault conditions [5].”
BackgroundBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Novel Diagnostic Techniques for Rotating Electrical Machines—A Review
Frosini, L. (2020) · Energies · doi:10.3390/en13195066 · Cited by 67
“It is important to note that stator shorts are more dangerous for PMSMs, as they may cause magnetic field strengths greater than the coercivity of magnets, permanently demagnetizing the magnets [25].”
BackgroundFault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64
D-Q Current Signature-Based Faulted Phase Localization for SM-PMAC Machine Drives
Kuruppu, S. S., & Kulatunga, N. A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334652 · Cited by 51
Hang, J., Zhang, J., Cheng, M., & Wang, Z. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6647169 · Cited by 36
“Motor current signature analysis (MCSA) based on Fast Fourier transform (FFT) is the most widely used to deal with the problems in electrical motors [3]-[5].”
MethodKrzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T. (2020) · Energies · doi:10.3390/en14010153 · Cited by 33
Wang, B., Wang, J., Griffo, A., & Huang, L. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2908595 · Cited by 33
Improved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30
“Among these methods, the MCSA is more favourable since the stator current has already existed in the PMSM control system [24].”
MethodAn effective method for detection of stator fault in PMSM with 1D-LBP
Mi̇naz, M. R. (2020) · ISA Transactions · doi:10.1016/j.isatra.2020.07.013 · Cited by 23
Guefack, F. L. T., Kiselev, A., & Kuznietsov, A. (2018) · 2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2018.8445403 · Cited by 19
A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13
“It is due to the variation in harmonic components in the stator current [20].”
Background
Metadata
- Authors
- Gandhi, A., Corrigan, T., & Parsa, L.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1564-1575
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2145223406
- Cited by
- 544
- References
- 54
- FWCI
- 43.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.