Wind Energy System With Integrated Functions of Active Power Transfer, Reactive Power Compensation, and Voltage Conversion
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
As the power of wind energy system increases, the control of their active and reactive power becomes increasingly more important from a system standpoint given that these are typical frequency and voltage control parameters. In this paper, a family of wind energy systems with integrated functions of active power transfer, reactive power compensation, and voltage conversion is proposed. The proposed wind energy systems using solid-state transformer (SST) can effectively suppress the voltage fluctuation caused by the transient nature of wind energy without additional reactive power compensator and, as such, may enable the large penetration of wind farm (WF) into the power grid. To this end, a simulation study for WF driven by squirrel-cage induction generators is presented to verify the effectiveness of the proposed system. In addition, a modular-type high-voltage and high-power three-phase SST topology is presented for the proposed system, and its basic building block, which is a single-phase SST, is analyzed. The functions of SST in the presented wind energy system are verified in a single-phase laboratory prototype with scaled-down experiments. Lastly, cost issue of the proposed technology is analyzed with comparison to the traditional one.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 3×
“On the one hand, efforts are focused on topology investigation in this new technology for high-voltage and high-power application [12]–[15].”
BackgroundSelf-citationDynamic modeling of doubly fed induction generator wind turbines
Ekanayake, J. B., Holdsworth, L., Wu, X., & Jenkins, N. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.811178 · Cited by 733 · cited 1×
“Presently, there are three main WF architectures, namely, SCIG-based wind energy system [21], doubly fed induction generator (DFIG)-based wind energy system [22], and directly driven synchronous generator (DDSG)-based wind energy system [23], shown in Fig.”
BackgroundPwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundGrid Integration of Large DFIG-Based Wind Farms Using VSC Transmission
Xu, L., Yao, L., & Sasse, C. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901306 · Cited by 428
Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC
Molinas, M., Suul, J. A., & Undeland, T. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921169 · Cited by 426
Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM
Song, W., & Huang, A. Q. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036019 · Cited by 358 · cited 1×
“redundant design can be incorporated to achieve fault-tolerant operation [27].”
BackgroundSelf-citationA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System
Han, C., Huang, A. Q., Baran, M. E., Bhattacharya, S., Litzenberger, W., Anderson, L., Johnson, A. L., & Edris, A.-A. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.888031 · Cited by 307
Self-citationA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
On Integration of Solid-State Transformer With Zonal DC Microgrid
She, X., Huang, A. Q., Lukic, S., & Baran, M. E. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2187317 · Cited by 254 · cited 2×
“On the other hand, SST is considered as the promising candidate for the applications where low-frequency transformers are dominating, such as traction/locomotives, solar farm, wind farm (WF), charge station, and smart grid, for reducing the volume and weight of the system [16]–[20].”
BackgroundSelf-citationQiao, W., Harley, R. G., & Venayagamoorthy, G. K. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2001456 · Cited by 217
Voltage and Transient Stability Support by Wind Farms Complying With the E.ON Netz Grid Code
Ullah, N. R., Thiringer, T., & Karlsson, D. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.907523 · Cited by 180 · cited 1×
“Reactive power compensators, such as STATCOM, are hence good solutions for regulating the PCC voltage [3]–[8], and it is also shown in Fig.”
BackgroundNew Configuration of Traction Converter With Medium-Frequency Transformer Using Matrix Converters
Drabek, P., Peroutka, Z., Pittermann, M., & Cedl, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2138114 · Cited by 148 · cited 1×
“On the other hand, SST is considered as the promising candidate for the applications where low-frequency transformers are dominating, such as traction/locomotives, solar farm, wind farm (WF), charge station, and smart grid, for reducing the volume and weight of the system [16]–[20].”
BackgroundShe, X., Huang, A. Q., & Wang, G. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2142422 · Cited by 144 · cited 2×
“It is worth to point out that there is no limitation for the number of modules since this is the key feature of the cascaded-type multilevel converter; the number of the modules depends on the operating voltage and power device adopted [13].”
BackgroundSelf-citation10 kV/120 A SiC DMOSFET half H-bridge power modules for 1 MVA solid state power substation
Grider, D., Das, M., Agarwal, A., Palmour, J., Leslie, S., Ostop, J., Raju, R., Schutten, M., & Hefner, A. (2011) · 2011 IEEE Electric Ship Technologies Symposium · doi:10.1109/ests.2011.5770855 · Cited by 115 · cited 1×
“8-kV-to-465-V three-phase SST has already been designed, and 1-MVA single-phase SST has been developed, which verifies the feasibility of high-voltage and high-power field application of the technology [24].”
BackgroundExtending the Life of Gear Box in Wind Generators by Smoothing Transient Torque With STATCOM
Molinas, M., Suul, J. A., & Undeland, T. M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2035464 · Cited by 99 · cited 1×
“install reactive power compensation devices, such as static compensators (STATCOMs) [3]–[11].”
BackgroundDesign and hardware implementation of Gen-1 silicon based solid state transformer
Wang, G., Baek, S., Elliott, J., Kadavelugu, A., Wang, F., She, X., Dutta, S., Liu, Y., Zhao, T., Yao, W., et al. (2011) · 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2011.5744766 · Cited by 99
Self-citationOptimal Integration of an Offshore Wind Farm to a Weak AC Grid
Koutiva, X. I., Vrionis, T. D., Vovos, N. A., & Giannakopoulos, G. B. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2005.859275 · Cited by 90
León, A. E., Farias, M. F., Battaiotto, P. E., Solsona, J. A., & Valla, M. I. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2088141 · Cited by 88 · cited 2×
“Presently, there are three main WF architectures, namely, SCIG-based wind energy system [21], doubly fed induction generator (DFIG)-based wind energy system [22], and directly driven synchronous generator (DDSG)-based wind energy system [23], shown in Fig.”
BackgroundVoltage and power balance control for a cascaded multilevel solid state transformer
Zhao, T., Wang, G., Zeng, J., Dutta, S., Bhattacharya, S., & Huang, A. Q. (2010) · 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2010.5433584 · Cited by 80 · cited 1×
“SST have already been presented in the previous works [28], [29], where the voltage and current in the SST can be effectively balanced.”
BackgroundSelf-citationDu, S. B. Y., Wang, G., & Bhattacharya, S. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5674991 · Cited by 75
She, Y., She, X., & Baran, M. E. (2011) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2159607 · Cited by 68 · cited 1×
“This sensitivity is exacerbated in the case of SCIG, since this type of generator is an inherent consumer of reactive power [2].”
BackgroundSelf-citationHexagram-Converter-Based STATCOM for Voltage Support in Fixed-Speed Wind Turbine Generation Systems
Slepchenkov, M., Smedley, K. M., & Wen, J. X. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2052536 · Cited by 63
Gupta, R. K., Castelino, G. F., Mohapatra, K. K., & Mohan, N. (2009) · 2009 35th Annual Conference of IEEE Industrial Electronics · doi:10.1109/iecon.2009.5414881 · Cited by 39 · cited 1×
“In addition, some of the previous SST topologies cannot provide the reactive power compensation due to lack of dc links [18].”
BackgroundPower Electronic Transformer application to grid connected photovoltaic systems
Brando, G., Dannier, A., & Rizzo, R. (2009) · 2009 International Conference on Clean Electrical Power · doi:10.1109/iccep.2009.5211954 · Cited by 31
Performance of a Distribution Intelligent Universal Transformer under Source and Load Disturbances
Lai, J., Maitra, A., & Goodman, F. (2006) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2006.256606 · Cited by 31 · cited 1×
“On the one hand, efforts are focused on topology investigation in this new technology for high-voltage and high-power application [12]–[15].”
BackgroundBaek, S. (2009) · NCSU Libraries Repository (North Carolina State University Libraries) · Cited by 20
Performance optimization of low-speed induction generators for direct drive wind turbines
Madescu, G., TRICA, A., Budişan, N., Proștean, O., Biriescu, M., & Moţ, M. (2007) · IEEE Electrical Power and Energy Conference (EPEC) · doi:10.1109/epc.2007.4520324 · Cited by 8 · cited 1×
“Presently, there are three main WF architectures, namely, SCIG-based wind energy system [21], doubly fed induction generator (DFIG)-based wind energy system [22], and directly driven synchronous generator (DDSG)-based wind energy system [23], shown in Fig.”
BackgroundPlug-and-play control module for variable speed wind turbine under unknown aerodynamics
She, Y., & She, X. (2010) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2010.5675204 · Cited by 4 · cited 3×
“Reactive power compensators, such as STATCOM, are hence good solutions for regulating the PCC voltage [3]–[8], and it is also shown in Fig.”
BackgroundSelf-citation
Research works printed but not linked: 3
- 2011, Field Prototype Development of Intelligent Universal Transformer
- wang, 2011, Comparison of different control strategies for 20 KVA solid state transformer, Proc IEEE ECCE, 3173
- 2009, Wind Energy The Facts A Guide to the Technology Economics and Future of Wind Power
Cited by
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Self-citationWu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
“This might be used in applications such as wind generation systems [20].”
MethodSelf-citationHuber, J. E., & Kolar, J. W. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954023 · Cited by 264
“Looking at lower power levels, [15] compares the cost of four different topologies suitable for a 50 kVA SST’s high-voltage side converter and [16] provides a cost breakdown of a laboratory-scale prototype of an SST for wind energy applications and, as a side note, mentions an estimated cost reduction by a factor of f…”
Background
Metadata
- Authors
- She, X., Huang, A. Q., Wang, F., & Burgos, R.
- Affiliations
- North Carolina State University (US)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-10
- Volume
- 60
- Issue
- 10
- Pages
- 4512-4524
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2000794749
- Cited by
- 161
- References
- 30
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 11 · 2020: 13 · 2019: 13 · 2018: 13 · 2017: 14 · 2016: 14 · 2015: 17 · 2014: 22 · 2013: 10
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- National Science Foundation
- North Carolina State University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- wind energy systems, solid-state transformer, reactive power compensation, active power transfer, voltage conversion, voltage fluctuation suppression, grid integration of wind power, squirrel cage induction generator, voltage and frequency regulation, cost analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.