The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Wind Energy System With Integrated Functions of Active Power Transfer, Reactive Power Compensation, and Voltage Conversion
Abstract
As the power of wind energy system increases, the control of their active and reactive power becomes increasingly more important from a system standpoint given that these are typical frequency and voltage control parameters. In this paper, a family of wind energy systems with integrated functions of active power transfer, reactive power compensation, and voltage conversion is proposed. The proposed wind energy systems using solid-state transformer (SST) can effectively suppress the voltage fluctuation caused by the transient nature of wind energy without additional reactive power compensator and, as such, may enable the large penetration of wind farm (WF) into the power grid. To this end, a simulation study for WF driven by squirrel-cage induction generators is presented to verify the effectiveness of the proposed system. In addition, a modular-type high-voltage and high-power three-phase SST topology is presented for the proposed system, and its basic building block, which is a single-phase SST, is analyzed. The functions of SST in the presented wind energy system are verified in a single-phase laboratory prototype with scaled-down experiments. Lastly, cost issue of the proposed technology is analyzed with comparison to the traditional one.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 3×
“On the one hand, efforts are focused on topology investigation in this new technology for high-voltage and high-power application [12]–[15].”
BackgroundSelf-citationDynamic modeling of doubly fed induction generator wind turbines
Ekanayake, J. B., Holdsworth, L., Wu, X., & Jenkins, N. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.811178 · Cited by 733 · cited 1×
“Presently, there are three main WF architectures, namely, SCIG-based wind energy system [21], doubly fed induction generator (DFIG)-based wind energy system [22], and directly driven synchronous generator (DDSG)-based wind energy system [23], shown in Fig.”
BackgroundPwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundGrid Integration of Large DFIG-Based Wind Farms Using VSC Transmission
Xu, L., Yao, L., & Sasse, C. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901306 · Cited by 428
Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC
Molinas, M., Suul, J. A., & Undeland, T. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921169 · Cited by 426
Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM
Song, W., & Huang, A. Q. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036019 · Cited by 358 · cited 1×
“redundant design can be incorporated to achieve fault-tolerant operation [27].”
BackgroundSelf-citationA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System
Han, C., Huang, A. Q., Baran, M. E., Bhattacharya, S., Litzenberger, W., Anderson, L., Johnson, A. L., & Edris, A.-A. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.888031 · Cited by 307
Self-citationA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
Research works printed but not linked: 3
- 2011, Field Prototype Development of Intelligent Universal Transformer
- wang, 2011, Comparison of different control strategies for 20 KVA solid state transformer, Proc IEEE ECCE, 3173
- 2009, Wind Energy The Facts A Guide to the Technology Economics and Future of Wind Power
Cited by
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Self-citationWu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
“This might be used in applications such as wind generation systems [20].”
MethodSelf-citationHuber, J. E., & Kolar, J. W. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954023 · Cited by 264
“Looking at lower power levels, [15] compares the cost of four different topologies suitable for a 50 kVA SST’s high-voltage side converter and [16] provides a cost breakdown of a laboratory-scale prototype of an SST for wind energy applications and, as a side note, mentions an estimated cost reduction by a factor of f…”
BackgroundDesign of a Unified Power Controller for Variable-Speed Fixed-Pitch Wind Energy Conversion System
Chen, J., Lin, T., Wen, C., & Song, Y. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2547365 · Cited by 164
“growing energies due to policies fostering and technical maturity [1], [2].”
BackgroundKang, M., Kim, J., Wills, L. M., & Kim, J.-M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2460242 · Cited by 148
“sion systems (WECSs), which convert the kinetic energy of the wind into electricity, are one of the most rapidly growing sources of new electricity generation [1], [2].”
BackgroundInterpolated-DFT-Based Fast and Accurate Frequency Estimation for the Control of Power
Borkowski, J., Kania, D., & Mroczka, J. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2316225 · Cited by 142
“Some of typical designs that modify inverter topology are as follows: [18]—a suggested three-phase solid-state transform topology, [19]—a multilevel inverter topology with separated high- and low-frequency parts, [20]—an optimized hysteresis digital modulation control for a single-source double-cascaded inverter, and…”
BackgroundHannan, M. A., Al-Shetwi, A. Q., Mollik, M. S., Ker, P. J., Mannan, M., Mansor, M., Al‐Masri, H. M. K., & Mahlia, T. M. I. (2023) · Sustainability · doi:10.3390/su15053986 · Cited by 130
“Wind power generation using a squirrel cage induction generator (SCIG)- is one of three primary wind farm (WF) designs now in use [49]; a wind energy system using both a DFIG and a directly driven synchronous generator (DDSG) is explained in Figure 5 [50].”
BackgroundMethodA review on solid-state transformer: A breakthrough technology for future smart distribution grids
Mishra, D. K., Ghadi, M. J., Li, L., Hossain, M. J., Zhang, J., Ray, P. K., & Mohanty, A. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107255 · Cited by 128
Wang, X., Liu, J., Ouyang, S., Xu, T., Meng, F., & Song, S. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2434420 · Cited by 108
Tahir, Y., Khan, I., Rahman, S., Nadeem, M. F., Iqbal, A., Xu, Y., & Rafi, M. (2021) · IET Power Electronics · doi:10.1049/pel2.12141 · Cited by 107
Syed, I., & Khadkikar, V. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2614692 · Cited by 97
“2 (a) Regular DFIG configuration, (b) SST structure and (c) configuration suggested in [10].”
BackgroundMethodInfluentialVienna Rectifier With Power Quality Added Function
Kedjar, B., Kanaan, H. Y., & Al‐Haddad, K. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2286577 · Cited by 86
“2286577 Power quality issues are now directly addressed in power conversion processes at both the generation and distribution levels [16]–[22].”
BackgroundTan, Z., Ju, L., Li, H., Li, J., & Zhang, H. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.06.061 · Cited by 89
Basu, K., Shahani, A., Sahoo, A. K., & Mohan, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320996 · Cited by 84
“Another major area of application is highpower-density electric motor drives, for example, in 1) electric traction [8]–[10], 2) wind power [11], [12], and 3) medium voltage ASDs [13].”
BackgroundGao, R., She, X., Husain, I., & Huang, A. Q. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2679679 · Cited by 76
“SST-interfaced wind system focuses on a squirrel-cage induction generator, which tends to be obsolete for modern wind turbines [17].”
BackgroundSelf-citationImplementation of LLMF Control Algorithm for Three-Phase Grid-Tied SPV-DSTATCOM System
Agarwal, R. K., Hussain, I., & Singh, B. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2630659 · Cited by 70
“[19]–[21] and advanced control algorithms [22]–[25] have been reported in the literature.”
BackgroundAbu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“In [28], the authors build on the work of [29] to integrate a doubly fed induction generator (DFIG) using an SST (Figure 8).”
BackgroundMethodInfluentialBarros, L. A. M., Martins, A., & Pinto, J. G. O. (2022) · Energies · doi:10.3390/en15031078 · Cited by 79
Liu, J., & Zhao, N. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2748032 · Cited by 72
“At present, a lot of works about module-cascaded structure redundancy focus on the single-stage structures, such as modular multilevel converter or H-bridge inverter rather than on the two-stage structures, such as PETT, power electronic transformers (PET) [4]–[6], or solid-state transformers (SST) [7]–[9].”
BackgroundGorla, N. B. Y., Kolluri, S., Chai, M., & Panda, S. K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2873201 · Cited by 71
Control Strategy for Arc-Suppression-Coil-Grounded Star-Connected Power Electronic Transformers
Ouyang, S., Liu, J., Yang, Y., Chen, X., Song, S., & Wu, H. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2866871 · Cited by 62
“Therefore, the CHB has become today’s mainstream topology for the PET MV stage, including the European traction PET [3], [4], a Chinese 500-kVA distribution grid application electronic power transformer (EPT) [10] (in service since 2015), the future renewable electric energy delivery and management SST [6], photovolta…”
BackgroundChen, J., Chen, J., & Gong, C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2284148 · Cited by 61
“Among various kinds of renewable energy, wind energy is by far the fastest growing energy for its free availability, environmental friendliness, policies fostering, and the maturity of turbine techniques; and it has become a research focus and priority all over the world [1]–[3].”
BackgroundReview of Solid-State Transformer Applications on Electric Vehicle DC Ultra-Fast Charging Station
Valedsaravi, S., Aroudi, A. E., & Martinez-Salamero, L. (2022) · Energies · doi:10.3390/en15155602 · Cited by 56
Ghennam, T., Aliouane, K., Akel, F., François, B., & Berkouk, E. M. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.07.058 · Cited by 55
Coordinated control strategy for doubly‐fed induction generator with DC connection topology
Nian, H., & Yi, X. (2015) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2014.0347 · Cited by 55
Ravindran, R., & Massoud, A. M. (2025) · Microelectronic Engineering · doi:10.1016/j.mee.2025.112348 · Cited by 55
Capovilla, C. E., Casella, I. R. S., Filho, A. J. S., Barros, T. A. D. S., & Filho, E. R. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2331017 · Cited by 50
Barros, T. A. D. S., Neto, P. J. D. S., Paula, M. V. D., Moreira, A. B., Filho, P. S. N., & Filho, E. R. (2018) · IEEE Access · doi:10.1109/access.2018.2825607 · Cited by 49
Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295419 · Cited by 48
“former (SST) topology along with reactive-power delivery capability as in a STATCOM is presented in [9].”
MethodSomkun, S., & Chunkag, V. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2561260 · Cited by 48
“, active rectifiers [1], power quality improvement [2], distributed generation [3], more recently in battery chargers of electric vehicles [4], [5], and solid-state transformers [6].”
BackgroundChaine, S., & Tripathy, M. (2019) · Alexandria Engineering Journal · doi:10.1016/j.aej.2019.03.007 · Cited by 41
A Self-Sensing Stator-Current-Based Control System of a DFIG Connected to a DC-Link
Marques, G. D., & Iacchetti, M. F. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2426675 · Cited by 40
“Since permanentmagnet synchronous generators (PMSGs) and squirrel-cage induction generators (SCIGs) do not possess any intrinsic internal regulation capability, they need a full-power PWM ac-dc converter to achieve high performance control [6], [7].”
BackgroundSahoo, B., Routray, S. K., & Rout, P. K. (2019) · Iranian Journal of Science and Technology Transactions of Electrical Engineering · doi:10.1007/s40998-019-00215-5 · Cited by 40
Basu, K., & Mohan, N. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2311393 · Cited by 43
“PETs can be also employed for high-powerdensity electrical machine drives, for example, in wind power generation [3], [4], traction drives [5], [6], and medium-voltage”
Mollik, M. S., Hannan, M. A., Reza, M. S., Rahman, M. S. A., Lipu, M. S. H., Ker, P. J., Mansor, M., & Muttaqi, K. M. (2022) · Electronics · doi:10.3390/electronics11172648 · Cited by 41
“This single SST essentially substitutes two transformers: one STATCOM and a local capacitor [23].”
Chen, H., EL-Refaie, A. M., Zuo, Y., Cai, S., Xie, S., & Lee, C. H. T. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3114710 · Cited by 38
Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies
Wang, X., Liu, J., Ouyang, S., & Meng, F. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331701 · Cited by 37
Hu, Y., Li, Z., Zhang, H., Zhao, C., Gao, F., Luo, L., Luan, K., Wang, P., & Li, Y. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2965232 · Cited by 38
“face with renewable energy, and storage systems [5], [6].”
BackgroundChen, J., Chen, J., & Gong, C. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2293699 · Cited by 36
“Among various kinds of renewable energy, wind energy is treated as the most challenging one because of its free availability, policies fostering, and the maturity of turbine techniques [1]–[3].”
BackgroundPiazza, M. C. D., & Pucci, M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2478746 · Cited by 35
Dai, N., Zhang, W., Wong, M., Guerrero, J. M., & Lam, C. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0373 · Cited by 35
“ensure that the chief task of a grid-connected inverter is active power flow control [11-13].”
BackgroundA SYSTEMATIC LITERATURE REVIEW ON ENERGY-EFFICIENT TRANSFORMER DESIGN FOR SMART GRIDS
Manager Grade-1, P. &. M., Khan, M. A. M., Haque, R., Apex Footwear limited, D., Bajwa, A., & Instrumentation and Control Engineer, A. M. A. A. G. (2022) · American Journal of Scholarly Research and Innovation · doi:10.63125/6n1yka80 · Cited by 34
Solid-state transformer interfaced PMSG wind energy conversion system
Gao, R., Husain, I., Wang, F. “., & Huang, A. Q. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104517 · Cited by 33
“The previous preliminary works have demonstrated the feasibility of the concept while only focusing on squirrel cage induction generator [7].”
BackgroundSelf-citationSolid-State Transformers: Fundamentals, Topologies, Applications, and Future Challenges
Khan, S., Rahman, K., Tariq, M., Hameed, S., Alamri, B. R., & Babu, T. S. (2021) · Sustainability · doi:10.3390/su14010319 · Cited by 36
Design and demonstration of a 3.6kV–120V/10KVA solid state transformer for smart grid application
She, X., Yu, X., Wang, F. “., & Huang, A. Q. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803801 · Cited by 31
“This might be used in the applications such as wind generation system [16].”
MethodSelf-citationYao, P., Jiang, X., Xue, P., Ji, S., & Wang, F. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2984789 · Cited by 30
Self-citationA ZVS Range Enhancement Strategy for the DAB Converter by Using Blocking Capacitors
Liu, P., & Duan, S. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3016052 · Cited by 29
“THE dual-active-bridge (DAB) converter [1] is widely used in many applications, such as renewable energy system [2], electric vehicles (EVs) [3], [4], and dc transformer [5]–[7].”
BackgroundTan, Z., Li, H., Ju, L., & Song, Y. (2014) · Energies · doi:10.3390/en7117282 · Cited by 27
Design Optimization of Medium-Frequency Transformer for DAB Converters With DC Bias Capacity
Yao, P., Jiang, X., Xue, P., Li, S., Lu, S., & Wang, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3010155 · Cited by 27
Self-citationControl scheme for DFIG converter system based on DC‐transmission
Yan, S., Zhang, A., Zhang, H., & Wang, J. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0430 · Cited by 27
Solid state transformer with low-voltage ride-through and current unbalance management capabilities
Alepuz, S., Gonzalez, F., Martin-Arnedo, J., & Martínez, J. A. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699316 · Cited by 26
Feng, M., Gao, C., Ding, J., Ding, H., Xu, J., & Zhao, C. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3061421 · Cited by 26
“is capable of realizing the transformation of multiple voltage levels, electrical isolation, power regulation and control, and providing access for renewable energies [6].”
BackgroundSolid state transformer application in wind based DG system
Paladhi, S., & Ashok, S. (2015) · IEEE International Conference on Signal Processing, Informatics, Communication and Energy Systems (SPICES) · doi:10.1109/spices.2015.7091563 · Cited by 26
Coordinated Grid-Forming Controller for Solid-State Transformer-Enabled PV Farms
Elshenawy, M. A., Radwan, A. A. A., & Mohamed, Y. A. I. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3291661 · Cited by 25
“This simple representation of the DAB stage has been adopted by [18], [35], [36], where a conversion ratio of 27.5, 50, and 9.8 has been used, respectively.”
MethodInfluentialLiu, C., Li, X., Zhi, Y., & Cai, G. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.052 · Cited by 26
Capacitor-less D-STATCOM for reactive power compensation
Rohouma, W. M., Balog, R. S., Peerzada, A. A., & Begovic, M. M. (2018) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2018.8372590 · Cited by 25
“Also, it will reduce the power transfer capability if not suitably controlled [1-3].”
BackgroundToward a flexible scenario generation tool for stochastic renewable energy analysis
Wang, T., Chiang, H., & Tanabe, R. (2016) · Power Systems Computation Conference · doi:10.1109/pscc.2016.7540991 · Cited by 24
“As the use of renewable energy grows, a deeper understanding and better management of renewable uncertainty is essential for secure and economic power system operations [2, 3, 4, 5, 6].”
BackgroundPenin, R., Lecointe, J., Parent, G., Brudny, J. F., & Belgrand, T. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2276772 · Cited by 22
“In order to explain every vibration components, the authors analyse the impact of the supply voltage harmonics [10]-[11] and the effects of local saturations in the magnetic circuit [12].”
Review on design and control of solid state transformer based microgrids
de Silva, H. H. H., Jayamaha, D. K. J. S., & Lidula, N. W. A. (2019) · AIMS energy · doi:10.3934/energy.2019.6.901 · Cited by 22
Gadelrab, R. G., Hamad, M. S., Abdel-Khalik, A. S., & Zawawi, A. E. (2015) · Journal of Energy Storage · doi:10.1016/j.est.2015.10.003 · Cited by 21
Abbas, S. R., Kazmi, S. A. A., Naqvi, M., Javed, A., Naqvi, S. R., Ullah, K., Khan, T. U. R., & Shin, D. R. (2020) · Energies · doi:10.3390/en13205513 · Cited by 20
“Ref: A B C D E F Miscellaneous [1] X X X Storage and PE control application [2] X X X X [3] X X Storage and PE control application [4] X X [5] X X Economics [6] X X [7] X Forecasting, policy, and economics [8] X X X X [9] Forecasting [10] X [11] X X Economics [12] X Economics [13] X X Policy and economics [14] X X X E…”
BackgroundSolid state transformer technologies and applications: A bibliographical survey
Adabi, M. E., Universitat Politecnica de Catalunya, B., & Martinez-Velasco, J. A. (2018) · AIMS energy · doi:10.3934/energy.2018.2.291 · Cited by 20
Grid-Supporting Renewable Energy Systems With Power Electronics Interfaces
Yan, S., Meegahapola, L. G., Yang, Y., & Blaabjerg, F. (2025) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2025.3615123 · Cited by 19
“Power electronics-based solutions, such as static var compensators (SVCs), static synchronous compensators (STATCOMs), active filters, and solid-state transformers, offer rapid response and flexible compensation capabilities [12].”
Hasanzadeh, S., Shojaeian, H., Mohsenzadeh, M. M., Heydarian‐Forushani, E., Alhelou, H. H., & Siano, P. (2022) · IEEE Access · doi:10.1109/access.2022.3172144 · Cited by 19
“Voltage stability is important in improving the safety and reliability of power systems and is one of the main factors in the power quality of networks [1-2].”
BackgroundErrami, Y., Ouassaid, M., Cherkaoui, M., & Maâroufi, M. (2014) · Studies in computational intelligence · doi:10.1007/978-3-319-11173-5_6 · Cited by 19
Huang, H. X., Mao, C., Lu, J., & Wang, D. (2014) · Energies · doi:10.3390/en7117330 · Cited by 18
Yao, P., Jiang, X., & Wang, F. (2020) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec39645.2020.9124400 · Cited by 18
Self-citationPMU-assisted overcurrent protection for distribution feeders employing Solid State Transformers
Hooshyar, H., Baran, M. E., Firouzi, S. R., & Vanfretti, L. (2017) · Sustainable Energy Grids and Networks · doi:10.1016/j.segan.2017.02.003 · Cited by 17
Butt, R. Z., Kazmi, S. A. A., Alghassab, M. A., Khan, Z. A., Altamimi, A., Imran, M. A., & Alruwaili, F. F. (2022) · Sustainability · doi:10.3390/su14052507 · Cited by 16
“The static synchronous compensator (STATCOM) incorporates a damping mechanism that solves the concerns of SVC, resulting in improved power quality and stability [29].”
BackgroundYang, R. H., Jin, J. X., Mu, S., Zhang, M., Jiang, S., & Chen, X. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108442 · Cited by 17
Chen, D., Huang, A. Q., Xu, Y., Wang, F. “., & Yu, W. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7049252 · Cited by 15
Self-citationControl Strategy for Single-Phase Open-Circuit Operation of a Modular Solid-State Transformer
Ouyang, S., Liu, J., Chen, X., & Yang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2885562 · Cited by 15
Bonanno, F., Capizzi, G., Sciuto, G. L., & Napoli, C. (2015) · International Conference on Clean Electrical Power · doi:10.1109/iccep.2015.7177554 · Cited by 14
“energy market [24], [25].”
A novel converter system for DFIG based on DC transmission
Yan, S., Zhang, A., Zhang, H., & Wang, J. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7049123 · Cited by 14
“SST substituted for power frequency transformer in the DFIG converter system in [16].”
MethodRani, N., & Malakar, T. (2022) · IETE Journal of Research · doi:10.1080/03772063.2022.2131640 · Cited by 13
“In particular, the erratic nature of wind speed causes wind power (WP) fluctuations that lead to power imbalances [13] side by side with inconsistent voltage profiles [14].”
BackgroundDevelopment of a Capacitor-less D-STATCOM for Power Quality Improvement in Low Voltage Network
Rohouma, W. M., Balog, R. S., Peerzada, A. A., & Begovic, M. M. (2019) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2019.8862419 · Cited by 13
“This further reduces the power transfer capability of the distribution feeder and increases the feeder active and reactive power losses [1-3].”
BackgroundSolid-State Transformer-Based DC Power Distribution Network for Shipboard Applications
Ismail, A., Abdel-Majeed, M. S., Metwly, M. Y., Abdel-Khalik, A. S., Hamad, M. S., Ahmed, S., Hamdan, E., & Elmalhy, N. A. (2022) · Applied Sciences · doi:10.3390/app12042001 · Cited by 13
“Concerning the power distribution applications, SSTs play a vital role in the integration of the renewable energy sources into the distribution systems, which improves the performance and power quality issues of the system using components with reduced size, cost, and complexity [18].”
BackgroundExperimental Study of the Summation of Flicker Caused by Wind Turbines
Redondo, K., Ruiz, G., Azcárate, I., Sáiz, P., Leturiondo, L. A., & de Gauna, S. R. (2019) · Energies · doi:10.3390/en12122404 · Cited by 12
“The implementation of power control methods in modern WTs leads to the reduction of voltage fluctuations [13,25].”
MethodVoltage Unbalance Compensation Based on Optimal Current Injection by SSTs
Babaei, M., Ghandehari, R., & Asadi, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3038098 · Cited by 12
“drives, wind power generation, distributed resources, smart grid, distribution network, and offshore energy generation [10].”
BackgroundMipoung, O. D., Lopes, L. A. C., & Pillay, P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273474 · Cited by 11
“However, these sophisticated WTs are not often economically viable for small diesel hybrid mini-grids [15].”
BackgroundGao, R., Husain, I., & Huang, A. Q. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7468353 · Cited by 11
“Researchers in [9] and [10] have proposed and verified the SST functions and application for wind generation system integration.”
BackgroundSelf-citationPeng, Y., Wang, H., Zhao, Q., Nan, D., & Li, W. (2022) · Applied Sciences · doi:10.3390/app122110906 · Cited by 11
Errami, Y., Obbadi, A., Sahnoun, S., Ouassaid, M., & Maâroufi, M. (2018) · Journal of Electrical and Computer Engineering · doi:10.1155/2018/3837959 · Cited by 11
Elbouchikhi, E., Feld, G., Amirat, Y., Benbouzid, M., & Gall, F. L. (2020) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2020.106661 · Cited by 11
Conceptualization and Multi-Objective Analysis of Multi-Cell Solid-State Transformers
Huber, J. (2016) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000164724 · Cited by 17
“Looking at lower power levels, [160] compares the cost of four different topologies suitable for a 50 kVA SST’s MV-side converter and [161] provides a cost breakdown of a laboratory-scale prototype of an SST for wind energy applications and, as a side note, mentions an estimated cost reduction by a factor of five when…”
BackgroundOuyang, S., Liu, J., Wang, X., Song, S., Hou, X., & Wu, T. (2015) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7168166 · Cited by 10
Direct power control (DPC) of PMSG based wind energy conversion system
Louar, F., Ouari, A., Omeiri, A., Senani, F., & Rahab, A. (2015) · doi:10.1109/intee.2015.7416794 · Cited by 10
“Among va renewable energy, wind energy is by far the energy for its free availability, environmen policies fostering, and the maturity of turb and it has become a research focus and prio world [1]–[2]–[3].”
BackgroundRobust Lyapunov-Based Power Controllers with Integral Action for a Wind Farm
Achar, A., Djeriri, Y., Benbouhenni, H., Bentaallah, A., Djehaf, M. A., Hanafi, S., & Çolak, İ. (2024) · Electric Power Components and Systems · doi:10.1080/15325008.2024.2311880 · Cited by 9
“Reactive power regulation is one of the most critical auxiliary services needed by the TSO because it is necessary to produce reactive power locally and because system stability is highly dependent on reactive power [36–38].”
A fault-tolerant power conversion topology for PMSG based Wind Power Systems
Scarcella, G., Scelba, G., Pulvirenti, M., & Gaeta, A. (2014) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2014.6960410 · Cited by 9
“Uninterrupted distributed generation is the key factor for improving power quality of the grid, mitigating voltage regulation problems and avoiding unplanned generation stoppages which cause income loss for the owners of such power generation units [4-9].”
BackgroundSolid State Transformers for Smart Grid Control and Applications- A Review
Keerthi Gopal, D., Shanavas, T. N., & Naufal, N. (2022) · International Conference on Futuristic Technologies in Control Systems & Renewable Energy (ICFCR) · doi:10.1109/icfcr54831.2022.9893598 · Cited by 10
“The structural advantages of using ST for interfacing wind farms with the grid are as follows: it eliminates the need for a capacitor bank, 2 transformers and 1 STATCOM in the case of SCIG based wind farm, 2 transformers and 1 STATCOM for DFIG based wind farm and converter, 2 transformers and 1 STATCOM for DDSG based…”
MethodAdvanced modeling of solid state transformer
Adabi, M. E. (2018) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-113997 · Cited by 10
An Overview of the Role of Solid State Transformer in Grid Connected Wind Farms
Kadandani, N. B., Dahidah, M., & Ethni, S. (2021) · International Renewable Energy Congress · doi:10.1109/irec52758.2021.9624851 · Cited by 9
Kallaste, A., Vaimann, T., & Belahcen, A. (2017) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eie.23.1.17581 · Cited by 8
Model predictive control of a capacitor-less VAR compensator based on a matrix converter
Shadmand, M. B., Balog, R. S., & Abu‐Rub, H. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048987 · Cited by 8
“INTRODUCTION Reactive power, denoted as volt ampere reactive (VAR) power, brings several undesirable consequences to an AC power system network such as the reduction of power transferring capability and increases in transmission line losses if not controlled appropriately [1-3].”
BackgroundTanabe, R., Amano, H., & Yokoyama, A. (2017) · doi:10.1109/ptc.2017.7981239 · Cited by 8
“As the use of renewable energy grows, a deeper understanding and better management of renewable variability and uncertainty is essential for secure and economic power systems [2, 3, 4, 5, 6].”
BackgroundTan, Z., Ju, L., Li, H., Qin, C., & Peng, D. (2015) · Mathematical Problems in Engineering · doi:10.1155/2015/741379 · Cited by 8
“On aspect of inflow forecast, it generally uses load demand and inflow historical data and classical forecast methods [4, 5], modern forecast methods [6–8], and intelligence forecastmethods [9–11] to forecast load demand and inflow in the next period of time.”
MethodComparison of four power electronic transformer topologies on unbalanced load correction capacity
Ouyang, S., Liu, J., Wang, X., Song, S., & Hou, X. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310183 · Cited by 7
Shi, J., Yang, W., Xue, F., Qiao, W., & Zhang, D. (2019) · Journal of Renewable and Sustainable Energy · doi:10.1063/1.5072789 · Cited by 7
Metadata
- Authors
- She, X., Huang, A. Q., Wang, F., & Burgos, R.
- Affiliations
- North Carolina State University (US)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-10
- Volume
- 60
- Issue
- 10
- Pages
- 4512-4524
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2000794749
- Cited by
- 161
- References
- 30
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 11 · 2020: 13 · 2019: 13 · 2018: 13 · 2017: 14 · 2016: 14 · 2015: 17 · 2014: 22 · 2013: 10
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- National Science Foundation
- North Carolina State University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- wind energy systems, solid-state transformer, reactive power compensation, active power transfer, voltage conversion, voltage fluctuation suppression, grid integration of wind power, squirrel cage induction generator, voltage and frequency regulation, cost analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.