An Adjustable-Speed PFC Bridgeless Buck–Boost Converter-Fed BLDC Motor Drive
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This paper presents a power factor corrected (PFC) bridgeless (BL) buck–boost converter-fed brushless direct current (BLDC) motor drive as a cost-effective solution for low-power applications. An approach of speed control of the BLDC motor by controlling the dc link voltage of the voltage source inverter (VSI) is used with a single voltage sensor. This facilitates the operation of VSI at fundamental frequency switching by using the electronic commutation of the BLDC motor which offers reduced switching losses. A BL configuration of the buck–boost converter is proposed which offers the elimination of the diode bridge rectifier, thus reducing the conduction losses associated with it. A PFC BL buck–boost converter is designed to operate in discontinuous inductor current mode (DICM) to provide an inherent PFC at ac mains. The performance of the proposed drive is evaluated over a wide range of speed control and varying supply voltages (universal ac mains at 90–265 V) with improved power quality at ac mains. The obtained power quality indices are within the acceptable limits of international power quality standards such as the IEC 61000-3-2. The performance of the proposed drive is simulated in MATLAB/Simulink environment, and the obtained results are validated experimentally on a developed prototype of the drive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power electronics converters, applications and design
Robinson, F. V. P. (1997) · Microelectronics Journal · doi:10.1016/s0026-2692(97)87859-7 · Cited by 5,075
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
Self-citationA review of single-phase improved power quality ac~dc converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.817609 · Cited by 1,297 · cited 3×
“On the other hand, DCM requires a single voltage sensor for dc link voltage control, and inherent PFC is achieved at the ac mains, but at the cost of higher stresses on the PFC converter switch; hence, DCM is preferred for low-power applications [9], [10].”
BackgroundSelf-citationPerformance Evaluation of Bridgeless PFC Boost Rectifiers
Huber, L., Jang, Y., & Jovanovic, M. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921107 · Cited by 865
Energy-management system for a hybrid electric vehicle, using ultracapacitors and neural networks
Moreno, J., Ortuzar, M. E., & Dixon, J. W. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.870880 · Cited by 748 · cited 1×
“These BLDC motors are not limited to household applications, but these are suitable for other applications such as medical equipment, transportation, HVAC, motion control, and many industrial tools [2]–[4].”
BackgroundModeling of permanent magnet motor drives
Pillay, P., & Krishnan, R. M. (1988) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.9176 · Cited by 674
Singh, B., Singh, S., Chandra, A., & Al‐Haddad, K. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2166798 · Cited by 416 · cited 3×
“On the other hand, DCM requires a single voltage sensor for dc link voltage control, and inherent PFC is achieved at the ac mains, but at the cost of higher stresses on the PFC converter switch; hence, DCM is preferred for low-power applications [9], [10].”
BackgroundSelf-citationBridgeless SEPIC PFC Rectifier With Reduced Components and Conduction Losses
Mahdavi, M., & Farzanehfard, H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2095393 · Cited by 285 · cited 2×
“For further improvement in efficiency, bridgeless (BL) converters are used which allow the elimination of DBR in the front end [13]–[21].”
BackgroundMethodBridgeless High-Power-Factor Buck Converter
Jang, Y., & Jovanović, M. M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2068060 · Cited by 255 · cited 4×
“The BL buck [13] and boost [14], [15] converter configurations are not suitable for the required application due”
BackgroundMethodInfluentialNew Efficient Bridgeless Cuk Rectifiers for PFC Applications
Fardoun, A. A., Ismail, E. H., Sabzali, A. J., & Al-Saffar, M. A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2182662 · Cited by 245 · cited 1×
“A new family of BL SEPIC and Cuk converters has been reported in the literature [17]–[21] but requires a large number of components and has losses associated with it.”
Background
Cited by
Singh, A. K., & Pathak, M. K. (2018) · 2018 IEEE 8th Power India International Conference (PIICON) · doi:10.1109/poweri.2018.8704399 · Cited by 30
Mishra, A. K., Singh, A. K., & Kim, T. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0003 · Cited by 9
“) are employed to achieve variable output voltage and power factor correction (PFC) at front-stage [3, 12, 13].”
Method
Metadata
- Authors
- Bist, V., & Singh, B.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2014-06
- Volume
- 61
- Issue
- 6
- Pages
- 2665-2677
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2172180639
- Cited by
- 211
- References
- 13
- FWCI
- 11.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Adjustable-Speed PFC Bridgeless Buck–Boost Converter-Fed BLDC Motor Drive. https://app.cochat.ai/papers/10.1109/tie.2013.2274424
- The paper
- Bist, V., & Singh, B. (2014). An Adjustable-Speed PFC Bridgeless Buck–Boost Converter-Fed BLDC Motor Drive. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2013.2274424
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.