The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dynamic Stability Analysis of Synchronverter-Dominated Microgrid Based on Bifurcation Theory
Abstract
In the traditional power grid, inverter-interfaced distributed energy resources are widely used in microgrids such as conventional synchronous generators (SGs) in the traditional power grid. They are expected to decrease the rotational inertia and spinning reserve capacity that are specific to SGs, while synchronverters can compensate for the loss. Thus, an increasing number of interfaced inverters may act as synchronverters in a microgrid. The dynamic stability of the synchronverter-dominated microgrid must thus be carefully evaluated to ensure the reliable operation of this type of system. This paper presents a nonlinear model of a synchronverter-dominated microgrid. The eigenvalues of the system state matrix, along with the participation factors, are analyzed to determine the predominant parameters affecting the stability. Bifurcation theory is then used to predict and describe the unstable phenomenon as the system parameters fluctuate; the effect of these parameters on the system stability is then examined. A simulation on MATLAB/Simulink and experiments were performed and results validated the presented analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit
Zhong, Q.-C., Nguyen, P.-L., Ma, Z., & Sheng, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2258684 · Cited by 1,026
Cited by
Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2866122 · Cited by 546
Self-citationFuture low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Improvement of Frequency Regulation in VSG-Based AC Microgrid Via Adaptive Virtual Inertia
Hou, X., Sun, Y., Zhang, X., Lu, J., Wang, P., & Guerrero, J. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2923734 · Cited by 367
Cheng, H., Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2965152 · Cited by 254
Self-citationRobust Stability Analysis of Synchronverters Operating in Parallel
Rosso, R., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896707 · Cited by 117
Robust Stability Analysis of LCL Filter Based Synchronverter Under Different Grid Conditions
Rosso, R., Cassoli, J., Buticchi, G., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2867040 · Cited by 89
“Similar conclusions have been drawn in [22], where the stability of a synchronverterdominated microgrid has been investigated.”
Metadata
- Authors
- Shuai, Z., Hu, Y., Peng, Y., Tu, C., & Shen, Z. J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-09
- Volume
- 64
- Issue
- 9
- Pages
- 7467-7477
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2572181832
- Cited by
- 174
- References
- 1
- FWCI
- 20.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.