Control of a PMSM With Quadruple Three-Phase Star-Connected Windings Under Inverter Short-Circuit Fault
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
This paper proposes a novel approach for the control of a permanent magnet synchronous machine with a quadruple three-phase star-connected winding configuration after a short-circuit (SC) fault in one voltage source inverter. The approach includes an adaption of the closed-loop current control that allows operation of the faulty unit to proceed without the need to adapt the reference currents. This allows an operation of the faulty drive with increased postfault mean torque. Additionally, a strategy for postfault torque error compensation is proposed, which can be used to reduce the torque ripple while the load distribution is better balanced. Results are respectively compared to the case when applying a symmetric SC to the faulty unit, which is the conventional strategy in case of a transistor SC fault. The current limit of the drive is considered in all cases. The benefits of the approach are validated through experimental tests.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, from the FTC point of view, the most commonly used motor structure includes multiphase and modular structures [314].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [314]
Citations
Cites
Multiphase Electric Machines for Variable-Speed Applications
Levi, E. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918488 · Cited by 2,157 · cited 1×
“One of the mostly used topologies is the dual three-phase configuration [8].”
MethodOverview of Electric Motor Technologies Used for More Electric Aircraft (MEA)
Cao, W., Mecrow, B. C., Atkinson, G. J., Bennett, J. W., & Atkinson, D. J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2165453 · Cited by 1,026 · cited 2×
“Some of the faults with the highest failure rate in electric drives are defects of the power electronics [1].”
BackgroundRecent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927 · cited 1×
“Furthermore, the PMSMmay produce rated power at the maximum [19], [26], [27].”
BackgroundWelchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658 · cited 1×
“Furthermore, the PMSM may produce rated power at the maximum [19], [26], [27].”
BackgroundA strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374 · cited 2×
“This is done by adapting the transformation matrix [2], by maximizing the torque or by minimizing the copper losses.”
MethodFault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
Dwari, S., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045322 · Cited by 289
Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278 · cited 1×
“Different options are listed in [2]–[4].”
Strategies for the Fault-Tolerant Current Control of a Five-Phase Permanent-Magnet Motor
Bianchi, N., Bolognani, S., & Dai Pre, M. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900445 · Cited by 276 · cited 1×
“Results for maximized torque are given in [13]–[16] for five-phase machines and in [11] for a dual three-phase machine.”
BackgroundWang, W., Zhang, J., Cheng, M., & Li, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2559498 · Cited by 212
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“However, from the FTC point of view, the most commonly used motor structure includes multiphase and modular structures [314].”
Yepes, A. G., López, Ó., González‐Prieto, I., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030208 · Cited by 150
Yepes, A. G., González‐Prieto, I., López, Ó., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030221 · Cited by 96
Forstner, G., Kugi, A., & Kemmetmüller, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2986042 · Cited by 58
“, [11], [12], [13], [14], [15], [16], [17].”
Sun, Y., Zhao, W., Ji, J., Zheng, J., & Song, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3059546 · Cited by 46
Yepes, A. G., Fonseca, D. S. B., Antunes, H. R. P., López, Ó., Cardoso, A. J. M., & Doval‐Gandoy, J. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3206141 · Cited by 39
Sun, J., Li, C., Zheng, Z., Wang, K., & Li, Y. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3150759 · Cited by 38
“are two most common fault types in industrial drives [8], [10], [11].”
BackgroundReal-Time Diagnosis of Open Circuit Faults in Three-Phase Voltage Source Inverters
Luo, Y., Zhang, L., Chen, C., Li, K., & Li, K. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3371452 · Cited by 34
Fault-Tolerant Control of Modular Permanent Magnet Synchronous Motor Under Open-Circuit Faults
Chai, F., Gao, L., Yu, Y., & Liu, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2948363 · Cited by 31
“Due to the independence of the three-phase modules in the modular motor, it is more suitable to conduct existing fault-tolerant control strategy of three-phase motor in the faulty modules [6].”
BackgroundAbdel-Khalik, A. S., Massoud, A. M., & Ahmed, S. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2901574 · Cited by 21
“The stator is equipped with quadruple three-phase winding sets [20]–[22], which are connected in such a way as to emulate a conventional six-phase stator.”
BackgroundInfluence of Inverter Open Circuit Fault on Multiple Physical Quantities in the PMSM
Tang, H., Li, W., & Wu, Z. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3204414 · Cited by 20
“THE fault problem of permanent magnet synchronous motor (PMSM) and its drive system has always been a hot topic in the research of electric power transmission system [1], [2].”
BackgroundThe decoupled vector-control of PMSM based on nonlinear multi-input multi-output decoupling ADRC
Liu, Y., Wen, J., Xu, D., Huang, Z., & Zhou, H. (2014) · Advances in Mechanical Engineering · doi:10.1177/1687814020984255 · Cited by 19
“In 2019, Dieterle et al.(10) proposed a PMSM control approach for a quadruple three-phase star-connected winding during a short-circuit fault in one voltage source inverter.”
BackgroundSun, X., Liu, Z., Jiang, D., Li, A., Wang, P., & Qu, R. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3225826 · Cited by 17
“Moreover, the FTC operation of a four-quadrant motor is discussed in [16] and [17], in which the faulty module can be shorted or driven by the improved modulation method.”
MethodParvathy Thampi, M. S., & Chitra Kiran, N. (2019) · Communications on Applied Electronics · doi:10.5120/cae2019652808 · Cited by 12
“[50] that gives improves control against current and speed.”
BackgroundDevelopment of a Fault-Tolerant Permanent-Magnet Synchronous Motor
Feng, T., Hao, S., Zhang, X., Yang, T., & Wang, L. (2019) · IEEE Access · doi:10.1109/access.2019.2945604 · Cited by 11
“For example, a permanent-magnet synchronous motor (PMSM) with quadruple three-phase starconnected windings and a corresponding control algorithm was designed [1].”
Disturbance rejection speed sensorless control of PMSMs based on full order adaptive observer
Xu, Y., Wang, L., Yuan, W., & Yin, Z. (2021) · Journal of Power Electronics · doi:10.1007/s43236-021-00224-w · Cited by 9
Karthik, K., & Ponnambalam, P. (2025) · Scientific Reports · doi:10.1038/s41598-025-91464-4 · Cited by 7
“They might result in inaccurate readings from temperature, voltage, or current sensors, which can misinterpret battery conditions 54 .”
Si, B., Fu, Q., Wang, T., Gao, C., & Zhu, J. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2878013 · Cited by 6
“Dieterle proposed a control approach for the operation of a PMSM with multiple star-connected three-phase windings after an inverter short-circuit (SC) fault, which offered the possibility to operate the machine under a short-circuit fault without additional components such as phase separators [34].”
BackgroundAssessment of a Nine-phase Induction Motor Drive for Metal Industry Applications
Bastos, R. R., de Souza, T. S., de Carvalho, M. M., Silva, L. A. R., & Filho, B. J. C. (2019) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2019.8912328 · Cited by 4
“these machines should have a fault tolerant design: usually, stator with concentrated windings, in order to achieve electrical, mechanical, thermal, and magnetic isolation among the phases [41], [57], [58].”
BackgroundDynamic Modeling of Dual-star Permanent-magnet Synchronous Machines Using Look-up Tables
Mohammadi, A. A., Gyselinck, J. J. C., & Pop, A.-C. (2019) · Electric Vehicles International Conference (EV) · doi:10.1109/ev.2019.8893137 · Cited by 3
“In [13], a current-based dynamic model of quadruple-star PMSM considering saturation is reported.”
BackgroundEmerging Multiport Electrical Machines and Systems—Part II
Buja, G., Cheng, M., & Jovanovic, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2860078 · Cited by 2
Wang, Z., Li, Y., Yu, Z., & Du, J. (2023) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23857 · Cited by 2
Sliding Mode and Deadbeat Predictive Control of Permanent Magnet Synchronous Motor
Wang, Y., Li, T., Zhang, J., & Xiao, P. (2023) · IEEE International Power Electronics and Application Symposium (PEAS) · doi:10.1109/peas58692.2023.10395691 · Cited by 1
“Permanent magnet synchronous motor (PMSM) has become increasingly widely used in the driving field due to its advantages such as high power density, high conversion efficiency, simple structure, and small size[1-3].”
BackgroundFault-Tolerant Design of Paralleled Three-phase Topology with Active Bidirectional Switches
Sun, X., Liu, Z., Li, A., Jiang, D., Qu, R., Wang, Q., Liu, H., & Yang, G. X. (2023) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems59686.2023.10344353
“Only a few cases with special drive topology can be fault-tolerant[7-9].”
BackgroundModeling and Characterization of Quadruple Three-phase Winding Permanent Magnet Synchronous Machines
Nuli, P., C, V. K. R., & Namburi, K. M. (2024) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec60657.2024.10599046
“Various methods of modeling have been compared for modeling quad-wound machines and control methods for the same in [3], [4], and [8].”
BackgroundMethod
Metadata
- Authors
- Dieterle, O., Greiner, T., & Heidrich, P.
- Affiliations
- Pforzheim University of Applied Sciences (DE)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-01
- Volume
- 66
- Issue
- 1
- Pages
- 685-695
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2801503929
- Cited by
- 25
- References
- 34
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 3 · 2022: 7 · 2021: 2 · 2020: 1 · 2019: 6
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- State of Baden Wuerttemberg, Germany
- Ministry of Science, Research and Arts
- Cooperative Research Training Group
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power Systems and Control
- Keywords
- permanent magnet synchronous motor, closed-loop current control, torque ripple reduction, load balancing, current limiting
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.