Resilient Control Design for Load Frequency Control System Under False Data Injection Attacks
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Smart power grids are being enhanced by adding a communication infrastructure to improve their reliability, sustainability, and efficiency. Despite all of these significant advantages, their open communication architecture and connectivity renders the power systems' vulnerability to a range of cyberattacks. This article proposes a novel resilient control system for load frequency control (LFC) system under false data injection (FDI) attacks. It is common to use encryption in data transfer links as the first layer of defending mechanism; here, we propose a second defense layer that can jointly detect and mitigate FDI attacks on power systems. In this article, we propose a new anomaly detection technique that consists of a Luenberger observer and an artificial neural network (ANN). Since FDI attacks can happen rapidly, the observer structure is enhanced by the extended Kalman filter to improve the ANN ability for online detection and estimation. The resilient controller is designed based on the attack estimation, which can eliminate the need for control reconfiguration. The resiliency of the proposed design against FDI attacks is tested on the LFC system. The simulation results clearly show that the proposed control system can successfully detect anomalies and compensate for their adverse effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory and Practice of Recursive Identification
Lennart Ljung, A., & Söderström, T. (1983) · Lund University Publications (Lund University) · Cited by 3,989
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2011) · ACM Transactions on Information and System Security · doi:10.1145/1952982.1952995 · Cited by 2,428 · cited 1×
“In [13], the effects of an FDI attack on a smart grid system were investigated.”
BackgroundHe, Y., Mendis, G. J., & Wei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2703842 · Cited by 834 · cited 2×
“In general, they can be classified into two approaches: model-based approaches [12], [25]–[29]; and learning-based approaches [30]–[38].”
BackgroundManandhar, K., Cao, X., Hu, F., & Liu, Y. (2014) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2014.2357531 · Cited by 786 · cited 5×
“To demonstrate the advantages of the proposed AD system, we compared its performance with a Kalman filter based AD system [12], which belongs to the model-based AD category.”
BackgroundMethodInfluentialMachine Learning Methods for Attack Detection in the Smart Grid
Ozay, M., Esnaola, I., Yarman Vural, F. T., Kulkarni, S. R., & Poor, H. V. (2016) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2015.2404803 · Cited by 641 · cited 1×
“Learning-based approaches include methods that use arti-ficial intelligence for observing system states, e.g., artificial neural networks (ANN) [30]–[34] and machine learning approaches [35]–[40].”
MethodDelay-Dependent Stability for Load Frequency Control With Constant and Time-Varying Delays
Jiang, L., Yao, W., Wu, Q. H., Wen, J. Y., & Cheng, S. J. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2172821 · Cited by 604 · cited 1×
“The detail description of the model can be found in [2], [9], [41], and [42] { Ẋ(t) = AX(t) + BU(t) + DΔPl”
MethodGPS Vulnerability to Spoofing Threats and a Review of Antispoofing Techniques
Jafarnia-Jahromi, A., Broumandan, A., Nielsen, J., & Lachapelle, G. (2012) · International Journal of Navigation and Observation · doi:10.1155/2012/127072 · Cited by 413 · cited 2×
“Here, we assumed that the attacker spoofed the GPS by mimicking the GPS signal and altered the GPS time estimation in the PMUs of the LFC [15], [19].”
BackgroundMethodDefending Against False Data Injection Attacks on Power System State Estimation
Deng, R., Xiao, G., & Lu, R. (2015) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2015.2470218 · Cited by 344 · cited 2×
“In model-based approaches, an observer based on the dynamics of the model is designed to estimate system dynamics, e.g., sliding mode observer (SMO) [25], Kalman filter [12], [26], [29], weighted least square (WLS) observer [27], and principal component analysis (PCA) [28].”
MethodAn Artificial Neural Network Approach for Early Fault Detection of Gearbox Bearings
Bangalore, P., & Tjernberg, L. B. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2386305 · Cited by 339 · cited 2×
“In general, they can be classified into two approaches: model-based approaches [12], [25]–[29]; and learning-based approaches [30]–[38].”
BackgroundMethodTime Synchronization Attack in Smart Grid: Impact and Analysis
Zhang, Z., Gong, S., Dimitrovski, A. D., & Li, H. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2227342 · Cited by 325
Evaluation of the vulnerability of phasor measurement units to GPS spoofing attacks
Shepard, D. P., Humphreys, T. E., & Fansler, A. A. (2012) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2012.09.003 · Cited by 316 · cited 1×
“The U.S. Department of Transportation and the North American Electricity Reliability have listed the GPS spoofing attack as an imminent cyberthreat in 2001 [20] and 2012 [21], respectively.”
BackgroundBlind False Data Injection Attack Using PCA Approximation Method in Smart Grid
Yu, Z.-H., & Chin, W.-L. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2382714 · Cited by 305 · cited 2×
“In [28], PCA was used to ensure the integrity of data in state estimation of the power grid by filtering of faulty measurements.”
MethodData-Based Line Trip Fault Prediction in Power Systems Using LSTM Networks and SVM
Zhang, S., Wang, Y., Liu, M., & Bao, Z. (2017) · IEEE Access · doi:10.1109/access.2017.2785763 · Cited by 284 · cited 1×
“Machine learning approaches, e.g., deep neural network [38] and support vector machine [39], also suffer from the same problem; moreover, they need huge training dataset for learning different FDI attack scenarios.”
BackgroundQ-Learning-Based Vulnerability Analysis of Smart Grid Against Sequential Topology Attacks
Yan, J., He, H., Zhong, X., & Tang, Y. (2017) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2016.2607701 · Cited by 264
Chen, Y. Q., Fink, O., & Sansavini, G. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2721922 · Cited by 258 · cited 1×
“Learning-based approaches include methods that use arti-ficial intelligence for observing system states, e.g., artificial neural networks (ANN) [30]–[34] and machine learning approaches [35]–[40].”
MethodSpoofing GPS Receiver Clock Offset of Phasor Measurement Units
Jiang, X., Zhang, J., Harding, B. J., Makela, J. J., & Domínguez-García, A. D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2240706 · Cited by 249
Mu, C., Tang, Y., & He, H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2694396 · Cited by 240 · cited 1×
“The role of LFC, in a smart grid, is to keep the desired frequency and power interchanges at the desired level [9]–[11].”
BackgroundAbbaspour, A., Aboutalebi, P., Yen, K. K., & Sargolzaei, A. (2017) · ISA Transactions · doi:10.1016/j.isatra.2016.11.005 · Cited by 239 · cited 5×
“The EKF updating parameter for the i th element of an ANN can be described by [43] where k is the k th sampling instant and t = kτ .”
BackgroundMethodInfluentialSelf-citationTalebi, H. A., Khorasani, K., & Tafazoli, S. (2009) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2008.2004373 · Cited by 237
Two-Channel False Data Injection Attacks Against Output Tracking Control of Networked Systems
Pang, Z.-H., Liu, G.-P., Zhou, D., Hou, F., & Sun, D. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2535119 · Cited by 232 · cited 2×
“In general, they can be classified into two approaches: model-based approaches [12], [25]–[29]; and learning-based approaches [30]–[38].”
BackgroundMethodDistributed Load Sharing Under False Data Injection Attack in an Inverter-Based Microgrid
Zhang, H., Meng, W., Qi, J., Wang, X., & Zheng, W. X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793241 · Cited by 185 · cited 2×
“False data injection (FDI) attack, a type of cyberattack that aims the integrity of data, is emerging as a severe threat to smart grid systems, which can degrade the system performance or endanger its stability [1]–[6] .”
BackgroundMethodPreventing Time-Delay Switch Attack on Load Frequency Control in Distributed Power Systems
Sargolzaei, A., Yen, K. K., & Abdelghani, M. N. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2503429 · Cited by 183 · cited 2×
“The detail description of the model can be found in [2], [9], [41], and [42] where are the state and input vectors, respectively.”
BackgroundMethodSelf-citationFault diagnostics in smart micro-grids: A survey
Hare, J., Shi, X., Gupta, S., & Bazzi, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.122 · Cited by 173 · cited 1×
“Attacking one node can affect the other nodes by redistributing the load to them, which can cause cascade overload and consequently failure in the interconnected network and huge power outage [8].”
BackgroundAdaptive cyber‐physical system attack detection and reconstruction with application to power systems
Ao, W., Song, Y., & Wen, C. (2016) · IET Control Theory & Applications · doi:10.1049/iet-cta.2015.1147 · Cited by 172 · cited 3×
“In general, they can be classified into two approaches: model-based approaches [12], [25]–[29]; and learning-based approaches [30]–[38].”
BackgroundMethodMa, M., Zhang, C., Liu, X., & Chen, H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2613923 · Cited by 168
Foroutan, S. A., & Salmasi, F. R. (2017) · IET Cyber-Physical Systems Theory & Applications · doi:10.1049/iet-cps.2017.0013 · Cited by 153
Ultrafast Transmission Line Fault Detection Using a DWT-Based ANN
Abdullah, A. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2774202 · Cited by 149
A Neural Adaptive Approach for Active Fault-Tolerant Control Design in UAV
Abbaspour, A., Yen, K. K., Forouzannezhad, P., & Sargolzaei, A. (2018) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2018.2850701 · Cited by 138
Self-citation1Time and Frequency Measurements Using the Global Positioning System (GPS)
Lombardi, M. A., Nelson, L. M., Novick, A. N., et al. (2015) · Cited by 113
Vulnerability Analysis of Smart Grids to GPS Spoofing
Risbud, P., Gatsis, N., & Taha, A. F. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2830118 · Cited by 108 · cited 4×
“In other words, by mimicking the GPS signal, the attacker can alter the GPS time estimation in the PMU [15], [19].”
BackgroundMethodInfluentialSargolzaei, A., Yen, K. K., Abdelghani, M., Sargolzaei, S., & Cărbunar, B. (2017) · IEEE Access · doi:10.1109/access.2017.2731780 · Cited by 85 · cited 1×
“The detail description of the model can be found in [2], [9], [41], and [42] where are the state and input vectors, respectively.”
BackgroundSelf-citationChlela, M., Joós, G., Kassouf, M., & Brissette, Y. (2016) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2016.7741747 · Cited by 56 · cited 1×
“A hardware platform was introduced in [14], to examine the impact of FDI attacks on the microgrid performance index, i.e., the total load loss, the frequency nadir, and the time needed to reach frequency stability.”
MethodA Novel Sensor Fault Detection in an Unmanned Quadrotor Based on Adaptive Neural Observer
Aboutalebi, P., Abbaspour, A., Forouzannezhad, P., & Sargolzaei, A. (2017) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-017-0690-7 · Cited by 54 · cited 1×
“Learning-based approaches include methods that use arti-ficial intelligence for observing system states, e.g., artificial neural networks (ANN) [30]–[34] and machine learning approaches [35]–[40].”
MethodSelf-citationSecurity Challenges of Networked Control Systems
Sargolzaei, A., Abbaspour, A., Faruque, M. A. A., Eddin, A. S., & Yen, K. K. (2018) · Studies in systems, decision and control · doi:10.1007/978-3-319-74412-4_6 · Cited by 45 · cited 1×
“While small FDI attacks might not make the system unstable but its propagation and its long term effects can cause a major problem in the power system and can disturb the lives of consumers, government corporations, and businesses if they are not timely diagnosed and tackled [7].”
BackgroundSelf-citationAnalysis of Automotive Cyber-Attacks on Highways Using Partial Differential Equation Models
Ghanavati, M., Chakravarthy, A., & Menon, P. P. (2017) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2017.2760865 · Cited by 45
Jana, S., & De, A. (2017) · Canadian Journal of Electrical and Computer Engineering · doi:10.1109/cjece.2017.2751661 · Cited by 26
Nazarnia, H., Sarmasti, H., & Wills, W. O. (2019) · Safety Science · doi:10.1016/j.ssci.2019.02.014 · Cited by 24
Nazarnia, H., & Sarmasti, H. (2018) · Civil Engineering Journal · doi:10.28991/cej-03091165 · Cited by 18
Cited by
Ghiasi, M., Niknam, T., Wang, Z., Mehrandezh, M., Dehghani, M., & Ghadimi, N. (2023) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108975 · Cited by 494
A survey on attack detection, estimation and control of industrial cyber–physical systems
Zhang, D., Wang, Q.-G., Feng, G., Shi, Y., & Vasilakos, A. V. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.01.036 · Cited by 317
A Survey on Active Fault-Tolerant Control Systems
Abbaspour, A., Mokhtari, S., Sargolzaei, A., & Yen, K. K. (2020) · Electronics · doi:10.3390/electronics9091513 · Cited by 218
Self-citationDetection of False Data Injection of PV Production
Riggs, H., Tufail, S., Khan, M., Parvez, I., & Sarwat, A. I. (2021) · 2021 IEEE Green Technologies Conference (GreenTech) · doi:10.1109/greentech48523.2021.00012 · Cited by 23
Self-citationOn The Efficacy of Physics-Informed Context-Based Anomaly Detection for Power Systems
Nafees, M. N., Saxena, N., & Burnap, P. (2022) · 2022 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm) · doi:10.1109/smartgridcomm52983.2022.9961034 · Cited by 4
“For example, the authors in [10] proposed a neural network-based Luneberger observer to detect attacks in the AGC.”
Background
Metadata
- Authors
- Abbaspour, A., Sargolzaei, A., Forouzannezhad, P., Yen, K. K., & Sarwat, A. I.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2020-09
- Volume
- 67
- Issue
- 9
- Pages
- 7951-7962
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2977733636
- Cited by
- 219
- References
- 38
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.