Cited by 224Context-Aware Activity Recognition SystemsGait Recognition and AnalysisHuman Pose and Action Recognition

Multiscale Deep Feature Learning for Human Activity Recognition Using Wearable Sensors

Tang, Yin, Zhang, Lei, Min, Fuhong, He, Jun·2023·IEEE Transactions on Industrial Electronics

Abstract

Deep convolutional neural networks (CNNs) achieve state-of-the-art performance in wearable human activity recognition (HAR), which has become a new research trend in ubiquitous computing scenario. Increasing network depth or width can further improve accuracy. However, in order to obtain the optimal HAR performance on mobile platform, it has to consider a reasonable tradeoff between recognition accuracy and resource consumption. Improving the performance of CNNs without increasing memory and computational burden is more beneficial for HAR. In this article, we first propose a new CNN that uses hierarchical-split (HS) idea for a large variety of HAR tasks, which is able to enhance multiscale feature representation ability via capturing a wider range of receptive fields of human activities within one feature layer. Experiments conducted on benchmarks demonstrate that the proposed HS module is an impressive alternative to baseline models with similar model complexity, and can achieve higher recognition performance (e.g., 97.28%, 93.75%, 99.02%, and 79.02% classification accuracies) on UCI-HAR, PAMAP2, WISDM, and UNIMIB-SHAR. Extensive ablation studies are performed to evaluate the effect of the variations of receptive fields on classification performance. Finally, we demonstrate that multiscale receptive fields can help to learn more discriminative features (achieving 94.10% SOTA accuracy) in weakly labeled HAR dataset.

Integrity signals

Registry

Crossref · 10.1109/tie.2022.3161812

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Tang, Y., Zhang, L., Min, F., & He, J.
Affiliations
  • Nanjing Normal University (CN)
  • Nanjing University of Information Science and Technology (CN)
Venue
IEEE Transactions on Industrial Electronics
Published
2023-02
Volume
70
Issue
2
Pages
2106-2116
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W4286681770
Cited by
224
References
34
Citations by year
2026: 30 · 2025: 54 · 2024: 68 · 2023: 54 · 2022: 18
FWCI
15.88
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industrial Electronics (publishedVersion)
Funders
  • National Natural Science Foundation of China (61971228)
  • Natural Science Foundation of Jiangsu Province (BK20191371)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Human Pose and Action Recognition
Keywords
human activity recognition, wearable sensors, multiscale feature representation, convolutional neural networks, receptive fields, weakly labeled data, UCI-HAR, PAMAP2, WISDM

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review