The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Distributed Resilient Finite-Time Secondary Control for Heterogeneous Battery Energy Storage Systems Under Denial-of-Service Attacks
Abstract
This article addresses the problem of distributed resilient finite-time control of multiple heterogeneous battery energy storage systems (BESSs) in a microgrid subject to denial-of-service (DoS) attacks. Note that DoS attacks may block information transmission among BESSs by preventing the BESS from sending data, compromising the devices and jamming a communication network. A distributed secure control framework is presented, where an acknowledgment (ACK)-based attack detection strategy and a communication recovery mechanism are introduced to mitigate the impact of DoS attacks by repairing the paralyzed topology graphs caused by DoS attacks back into the initial connected graph. Under this framework, a distributed resilient finite-time secondary control scheme is proposed such that frequency regulation, active power sharing, and energy level balancing of BESSs can be achieved simultaneously in a finite time; meanwhile, operational constraints can be satisfied at any control transient time. Moreover, based on theoretical analysis, the impact of the duration time of DoS attacks on the convergence time of the control algorithm can be explicitly revealed. Finally, validity and effectiveness of the proposed control scheme are demonstrated by case studies on a modified IEEE 57-bus testing system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Problems in Networks of Agents With Switching Topology and Time-Delays
Olfati-Saber, R., & Murray, R. M. (2004) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2004.834113 · Cited by 12,788 · cited 2×
“According to [26], it is theoretically not possible for Battery 1 to achieve cooperative control.”
BackgroundGuerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
A survey on security control and attack detection for industrial cyber-physical systems
Ding, D., Han, Q.-L., Xiang, Y., Ge, X., & Zhang, X.-M. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.10.009 · Cited by 944
Self-citationRobust Droop Controller for Accurate Proportional Load Sharing Among Inverters Operated in Parallel
Zhong, Q.-C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2146221 · Cited by 890
Lu, X., Sun, K., Guerrero, J. M., Vasquez, J. C., & Huang, L. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279374 · Cited by 752
An Overview of Recent Advances in Fixed-Time Cooperative Control of Multiagent Systems
Zuo, Z., Han, Q.-L., Ning, B., Ge, X., & Zhang, X.-M. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2817248 · Cited by 658
Self-citationHe, G., Chen, Q., Kang, C., Pinson, P., & Xia, Q. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2424314 · Cited by 508
Yi, P., Hong, Y., & Liu, F. (2016) · Automatica · doi:10.1016/j.automatica.2016.08.007 · Cited by 478
Peng, C., Li, J., & Fei, M. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2634122 · Cited by 433
Cited by
Ge, X., Han, Q.-L., Ding, L., Wang, Y.-L., & Zhang, X.-M. (2020) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2020.3010825 · Cited by 565
Self-citationDeep Learning Based Attack Detection for Cyber-Physical System Cybersecurity: A Survey
Zhang, J., Pan, L., Han, Q.-L., Chen, C., Wen, S., & Xiang, Y. (2022) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2021.1004261 · Cited by 432
Self-citationChen, P., Liu, S., Chen, B., & Yu, L. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3142087 · Cited by 120
Secure Frequency Control of Hybrid Power System Under DoS Attacks via Lie Algebra
Cheng, Z., Yue, D., Shen, S., Hu, S., & Chen, L. (2022) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2022.3158550 · Cited by 54
Self-citation
Metadata
- Authors
- Ding, L., Han, Q.-L., Ning, B., & Yue, D.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2020-07
- Volume
- 16
- Issue
- 7
- Pages
- 4909-4919
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2991521149
- Cited by
- 258
- References
- 32
- FWCI
- 15.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distributed Resilient Finite-Time Secondary Control for Heterogeneous Battery Energy Storage Systems Under Denial-of-Service Attacks. https://app.cochat.ai/papers/10.1109/tii.2019.2955739
- The paper
- Ding, L., Han, Q.-L., Ning, B., & Yue, D. (2020). Distributed Resilient Finite-Time Secondary Control for Heterogeneous Battery Energy Storage Systems Under Denial-of-Service Attacks. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2019.2955739
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.