Joint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey
The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.
Abstract
This paper presents an analysis of rigid-body joint-angle measurement based on microelectromechanical-system (MEMS) biaxial accelerometers and uniaxial gyroscopes. In comparison to conventional magnetic and optical joint angular sensors, this new inertial sensing principle has the advantages of flexible installation and true contactless sensing. This paper focuses on the comparison of four different inertial-sensor combination methods that are reported in reference papers and utilizes the theory of rigid-body kinematics to explain and analyze their advantages and weaknesses. Experiments have also been conducted to further verify and strengthen the arguments put forward in the analysis. All experiments in this paper took place on a custom-built rigid-body robot arm model that can be manipulated by hand. Sensor calibration and accelerometer alignment issues are also described, and their details are discussed. The experiment results presented in this paper show significant differences with reference to the achieved angular accuracy for various situations when using the four different sensor combination methods. In some cases, the angular error based on one method is more than 0.04 rad, while that from another method is within ±0.005 rad. The noise levels of angular readings from different methods are also experimentally compared and analyzed. The conclusion drawn serves to guide readers toward a suitable method for their particular application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Integrating advanced sensors enable real-time capture of user motion data and physiological signals such as joint angles 1,2 , acceleration 3,4 , electromyography (EMG) [5][6][7] , electrocardiography (ECG) 8,9 , and electroencephalography (EEG) 10 , providing high-quality and diverse raw data support for HMIP.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [2]
In the citing paper
“Analyze motion state by detecting mechanical | changes such as acceleration and angular | velocity.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [2]
Citations
Cites
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286 · cited 1×
“D. CMRGD This method is reported in [ 10 ]. It uses the same hardware setup as in the CMRGI method but with a different algorithm.”
MethodDejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDetecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundLower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92 · cited 1×
“This method is reported in [11] and [12] and requires two biaxial accelerometers on both Li and Li−1 to calculate the joint angle θi.”
MethodPrecision calibration of fiber-optics gyroscopes for mobile robot navigation
Ojeda, L., Chung, H., & Borenstein, J. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2000.846333 · Cited by 54 · cited 1×
“... φi and φi−1 to calculate θi. When any Li starts moving, the change in its orientation angle ϕi is calculated by numerically integrating its gyroscope’s reading until the movement stops, and then, φi from the accelerometer is again used as ϕi. The numerical integration in this method also provides the typical probl…”
MethodA Method for Gait Analysis in a Daily Living Environment by Body-Mounted Instruments
Ohtaki, Y., Sagawa, K., & Inooka, H. (2001) · JSME International Journal Series C · doi:10.1299/jsmec.44.1125 · Cited by 52 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDesign and Calibration of an Integration-Free Accelerometer-Based Joint-Angle Sensor
Ghassemi, F., Tafazoli, S., Lawrence, P. D., & Hashtrudi-Zaad, K. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.904488 · Cited by 31 · cited 6×
“There is a lack of an error model in [3] and [ 4 ] for the method that they used.”
BackgroundMethodInfluentialJoint motion monitoring by accelerometers set at both near sides around the joint
Kurata, S., Makikawa, M., Kobayashi, H., Takahashi, A., & Tokue, R. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746978 · Cited by 29 · cited 2×
“The methods presented in this paper are based on the rigid-body kinematics model, so the experimental results cannot directly be related to nonrigid conditions such as those for the human body in [5]–[12].”
BackgroundMethodAn accelerometer-based joint angle sensor for heavy-duty manipulators
Ghassemi, F., Tafazoli, S., Lawrence, P. D., & Hashtrudi-Zaad, K. (2003) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2002.1014798 · Cited by 29
Research works printed but not linked: 5
- 2008, KXR94-2050
- 0, ADXRS612
- 0, ADS1274
- 0, Vert-X 22-24V
- 0, URM80CC
Cited by
Items 101–140 of 140
Dynamics Calibration of a Redundant Flexible Joint Robot based on Gyroscopes and Encoders
Schüthe, D., Wenk, F., & Frese, U. (2016) · International Conference on Informatics in Control, Automation and Robotics (ICINCO) · doi:10.5220/0005976603350346 · Cited by 3
“How accelerometers and gyroscopes can be utilized to obtain the state of flexible robots and use them for control was shown in (Staufer and Gattringer, 2012; Cheng and Oelmann, 2010).”
BackgroundOn using a gyroscope to measure the angular position
Mischie, S. (2012) · International Symposium on Electronics and Telecommunications (ISETC) · doi:10.1109/isetc.2012.6408139 · Cited by 3
McLean, L., Chen, L., & Robertson, W. S. P. (2015) · Adelaide Research & Scholarship (AR&S) (University of Adelaide) · Cited by 3
Joint angle measurement of manipulator and error compensation based on an IMU sensor
Zhang, T., Chen, S., Xu, G., Wang, C., & Tan, C. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.9167 · Cited by 3
Che, H., Zhao, X., Song, J., Liu, W., Wang, Y., Ai, C., Li, H., Chen, Z., & Wen, D. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3618412 · Cited by 2
“T HE measurement of angular information (such as angular displacement and angular acceleration) is of great significance in fields such as aerospace [1], [2], vehicle engineering [3], [4], [5], [6], and industrial automation [1], [7], [8].”
Kobierska, A., Podsędkowski, L., Poryzała, P., & Rakowski, P. (2016) · Prace Naukowe Politechniki Warszawskiej. Elektronika · Cited by 2
Motion Tracking of a High-Speed Multilink System Using Dynamic Measurements Fusion
Zhang, W., Steckenrider, J. J., & Furukawa, T. (2023) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4063798 · Cited by 3
Digital inclinometer for joint angles measurements with a real-time 3D-animation
Zabat, M., Ouadahi, N., Youyou, A., Ababou, A., & Ababou, N. (2015) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd.2015.7348258 · Cited by 2
“Joint angular sensors are widely used in the industry, from highly effective robots in product lines and heavy construction machines in building sites to small knobs on home appliances [11] as well as in rehabilitation or physical therapy [12-13].”
BackgroundAccuracy and Repeatability Tests on 6D Measurement Arm.
Rakowski, P., Kobierska, A., Podsędkowski, L., & Poryzała, P. (2017) · TU repository (Lodz University of Technology) · Cited by 2
Petruska, A. J., & Meek, S. G. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6048179 · Cited by 2
Study on ship attitude estimate algorithm based on MEMS IMU
Wu, X., & Liu, Y. (2022) · China Automation Congress (CAC) · doi:10.1109/cac57257.2022.10055143 · Cited by 2
“MEMS IMU has been widely used in the robot fields[4-6].”
MethodDesign and Non-Linearity Optimization of a Vertical Brushless Electric Power Steering Angle Sensor
Chen, J., & Guo, Y. (2024) · Sensors · doi:10.3390/s24082469 · Cited by 2
“Angle sensors are widely used in various applications where precise angle measurements are required, including automobiles [1], aviation servo systems [2], and industrial robots [3].”
BackgroundTanaka, K., Takahashi, T., & Hamaya, M. (2025) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros60139.2025.11245913 · Cited by 1
“Pose estimation for robotic manipulators without joint encoders has been pursued through a variety of approaches, including external vision systems [9], inertial measurements [10], and mechanism-intrinsic sensing [11].”
Jiang, Y., Cai, C., Yang, M., Liu, Z., Zhang, H., Liang, C., & Wang, D. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3682396 · Cited by 1
“Since they have ability to measure the basic linear and angular motions simultaneously, they have been widely used in aerospace, civil structure monitoring, intelligent equipment, medical auxiliary diagnosis, etc. [1], [2], [3], [4].”
Gyroscope-Free Link Parameter Measurement Using Accelerometers and Magnetometer
Vikas, V., & Crane, C. D. (2014) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2014-35360 · Cited by 1
“The DCMR method [15], [17] uses two dual-axis linear accelerometers (not symmetrically placed) per link to estimate the joint angle.”
MethodVestibular dynamic inclinometer and measurement of inclination parameters
Vikas, V. (2011) · Cited by 1
Kobierska, A., Podsędkowski, L., Poryzała, P., & Rakowski, P. (2017) · Journal of Automation Mobile Robotics & Intelligent Systems · doi:10.14313/jamris_2-2017/15 · Cited by 1
Schüthe, D., Wenk, F., & Frese, U. (2017) · Lecture notes in electrical engineering · doi:10.1007/978-3-319-55011-4_19 · Cited by 1
A methodology of orthopaedic measurement arm workspace determination
Kobierska, A., Podsędkowski, L., Rakowski, P., Rejmonczyk, S., Kaszowski, J., Olejniczak, K., Golasiński, B., & Kaczmarek, K. M. (2017) · TU repository (Lodz University of Technology) · Cited by 1
Knee replacement patients and wearable knee pads
Zhang, Y. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2711/1/012018 · Cited by 1
Research on MEMS-IMU Attitude Estimation Based on the Kalman Method
Zhong, H., Sun, C., Xu, S., HangWu, & Zhao, Y. (2023) · China Automation Congress (CAC) · doi:10.1109/cac59555.2023.10451780 · Cited by 1
Lee, S.-D., & Jung, S. (2019) · Asian Control Conference (ASCC) · Cited by 1
Leboutet, Q., Guadarrama-Olvera, J. R., Bergner, F., & Cheng, G. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9197169 · Cited by 2
Herbert Hardness Test Using Accelerometer for Swing Angle Detection
Suzuki, R., Kaburagi, T., MARUHASHI, H., Ishikawa, Y., Murakami, K., Mitsugi, H., Nakamura, M., & Matsubara, M. (2021) · Experimental Techniques · doi:10.1007/s40799-021-00438-4 · Cited by 1
Balasubramanyam, A., Patil, A. K., Chakravarthi, B., Ryu, J., & Chai, Y. H. (2021) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc52423.2021.9658750 · Cited by 1
“[5] attached IMUs to the body at strategic locations to capture bone segment orientation as quaternions.”
BackgroundMrozowski, J. (2012) · Zeszyty Naukowe. Rozprawy Naukowe / Politechnika Łódzka
ORIENTATION ESTIMATION USING KALMAN FILTERS WITH MULTIPLE SENSORS
Kelly, K., & McGinn, C. (2015) · Arrow@dit (Dublin Institute of Technology)
Development of a dual-axis optoelectronic precision level
Fan, K., Wang, T.-H., Lin, S.-Y., & Liu, Y.-C. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.905323
Implementation of low-cost laser range finder with object tracking function
Lee, J.-D., Tsai-Lin, C.-W., Liu, M.-C., & Chen, L. (2017) · International Conference on Control, Automation and Robotics (ICCAR) · doi:10.1109/iccar.2017.7942770
Development of non-restraint remote control system with touch panel and gyroscope sensor
KAEDE, K., SAKAIDA, S., & WATANUKI, K. (2015) · Transactions of the JSME (in Japanese) · doi:10.1299/transjsme.15-00177
Kobierska, A., Rakowski, P., & Podsędkowski, L. (2019) · Journal of Automation Mobile Robotics & Intelligent Systems · doi:10.14313/jamris/2-2019/15
“Recently, accelerometers are being employed as cheaper alternatives to standard sensors for angular measurement [3][4][5][7].”
MethodA New Potentiometer-Based Goniometer Design in Joint Angle Measurement
Shahtalebi, S., & Abouei, J. (2021) · Transactions on Machine Intelligence · doi:10.47176/tmi.2021.7
“The joint angle measurement has been emerged as a key factor in clinical researches due to its simple and comparable output that leads clinicians to assess treatments and compare individual features with reference databases [1], [2].”
BackgroundImplementación en hardware para la medición de la aceleración usando FPGA
Realpe-Muñoz, P., Erazo-Aux, J., Carvajal, J. H. C., Aux, J. E., & Occa, J. V. (2023) · Revista Sapientía · doi:10.54278/sapientia.v15i29.126
Olawore, I. (2023) · ISU Red - Research and eData (Illinois State University) · doi:10.30707/etd2023.20240124055107909572.999987
A Novel Approach for Upper Limbs Joint Angle Measurement Using Wearable IMU Sensors
Baklouti, S., Rezgui, T., Chaker, A., Mefteh, S., Mansour, K. B., Sahbani, A., & Bennour, S. (2024) · Mechanisms and machine science · doi:10.1007/978-3-031-59888-3_16
Joint Angle Monitoring Device for Outdoor Applications Using ESP-NOW
Machado, L. F., Portugal, I. S. F., Nohama, P., & Neto, G. N. N. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-93646-3_91
Feng, L., Chenliang, P. A. N., Yue, F. U., Yuyu, D. U. A. N., Yukun, G. U. O., Yishan, Z. H. O. U., & Chen, H. (2025) · Chinese Journal of Aeronautics · doi:10.1016/j.cja.2025.103941
Fish locomotor dynamics quantified using multiple inertial measurement units
White, C. F., Castro‐Santos, T., Goerig, E., & LAUDER, G. V. (2026) · Royal Society Open Science · doi:10.1098/rsos.251863
Metadata
- Authors
- Cheng, P., & Oelmann, B.
- Affiliations
- Mid Sweden University (SE)
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-02
- Volume
- 59
- Issue
- 2
- Pages
- 404-414
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2116716880
- Cited by
- 140
- References
- 14
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 9 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 7 · 2019: 12 · 2018: 5 · 2017: 13 · 2016: 10 · 2015: 16 · 2014: 12 · 2013: 10 · 2012: 9
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Keywords
- joint angle measurement, MEMS accelerometer, MEMS gyroscope, inertial sensors, sensor fusion, rigid body kinematics, non-contact sensing, sensor calibration, angular accuracy, angular noise, robot manipulators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.