Joint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey
The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.
Abstract
This paper presents an analysis of rigid-body joint-angle measurement based on microelectromechanical-system (MEMS) biaxial accelerometers and uniaxial gyroscopes. In comparison to conventional magnetic and optical joint angular sensors, this new inertial sensing principle has the advantages of flexible installation and true contactless sensing. This paper focuses on the comparison of four different inertial-sensor combination methods that are reported in reference papers and utilizes the theory of rigid-body kinematics to explain and analyze their advantages and weaknesses. Experiments have also been conducted to further verify and strengthen the arguments put forward in the analysis. All experiments in this paper took place on a custom-built rigid-body robot arm model that can be manipulated by hand. Sensor calibration and accelerometer alignment issues are also described, and their details are discussed. The experiment results presented in this paper show significant differences with reference to the achieved angular accuracy for various situations when using the four different sensor combination methods. In some cases, the angular error based on one method is more than 0.04 rad, while that from another method is within ±0.005 rad. The noise levels of angular readings from different methods are also experimentally compared and analyzed. The conclusion drawn serves to guide readers toward a suitable method for their particular application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Integrating advanced sensors enable real-time capture of user motion data and physiological signals such as joint angles 1,2 , acceleration 3,4 , electromyography (EMG) [5][6][7] , electrocardiography (ECG) 8,9 , and electroencephalography (EEG) 10 , providing high-quality and diverse raw data support for HMIP.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [2]
In the citing paper
“Analyze motion state by detecting mechanical | changes such as acceleration and angular | velocity.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [2]
Citations
Cites
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286 · cited 1×
“D. CMRGD This method is reported in [ 10 ]. It uses the same hardware setup as in the CMRGI method but with a different algorithm.”
MethodDejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDetecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundLower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92 · cited 1×
“This method is reported in [11] and [12] and requires two biaxial accelerometers on both Li and Li−1 to calculate the joint angle θi.”
MethodPrecision calibration of fiber-optics gyroscopes for mobile robot navigation
Ojeda, L., Chung, H., & Borenstein, J. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2000.846333 · Cited by 54 · cited 1×
“... φi and φi−1 to calculate θi. When any Li starts moving, the change in its orientation angle ϕi is calculated by numerically integrating its gyroscope’s reading until the movement stops, and then, φi from the accelerometer is again used as ϕi. The numerical integration in this method also provides the typical probl…”
MethodA Method for Gait Analysis in a Daily Living Environment by Body-Mounted Instruments
Ohtaki, Y., Sagawa, K., & Inooka, H. (2001) · JSME International Journal Series C · doi:10.1299/jsmec.44.1125 · Cited by 52 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDesign and Calibration of an Integration-Free Accelerometer-Based Joint-Angle Sensor
Ghassemi, F., Tafazoli, S., Lawrence, P. D., & Hashtrudi-Zaad, K. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.904488 · Cited by 31 · cited 6×
“There is a lack of an error model in [3] and [ 4 ] for the method that they used.”
BackgroundMethodInfluentialJoint motion monitoring by accelerometers set at both near sides around the joint
Kurata, S., Makikawa, M., Kobayashi, H., Takahashi, A., & Tokue, R. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746978 · Cited by 29 · cited 2×
“The methods presented in this paper are based on the rigid-body kinematics model, so the experimental results cannot directly be related to nonrigid conditions such as those for the human body in [5]–[12].”
BackgroundMethodAn accelerometer-based joint angle sensor for heavy-duty manipulators
Ghassemi, F., Tafazoli, S., Lawrence, P. D., & Hashtrudi-Zaad, K. (2003) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2002.1014798 · Cited by 29
Research works printed but not linked: 5
- 2008, KXR94-2050
- 0, ADXRS612
- 0, ADS1274
- 0, Vert-X 22-24V
- 0, URM80CC
Cited by
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
“, [7] and the references therein, that inertial measurement data can be used to calculate hinge joint angles when at least one IMU is attached to each side of the joint.”
BackgroundAn Indirect Eavesdropping Attack of Keystrokes on Touch Screen through Acoustic Sensing
Yu, J., Lu, L., Chen, Y., Zhu, Y., & Kong, L. (2021) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2019.2947468 · Cited by 181
“On the other hand, the angle a between the projection plane and plane passing through the central axes of the two smartphones can be estimated with the accelerometer and gyroscope through rotating the adversary’s smartphone from the projection plane to another plane [20].”
BackgroundA Self‐Powered Angle Sensor at Nanoradian‐Resolution for Robotic Arms and Personalized Medicare
Wang, Z., An, J., Nie, J., Luo, J., Shao, J., Jiang, T., Chen, B., Tang, W., & Wang, Z. L. (2020) · Advanced Materials · doi:10.1002/adma.202001466 · Cited by 177
Luo, H., Wang, M., Wong, P. K.-Y., & Cheng, J. C. P. (2020) · Automation in Construction · doi:10.1016/j.autcon.2019.103016 · Cited by 165
Research development of silicon MEMS gyroscopes: a review
Zhanshe, G., Cheng, F., Li, B., Le, C., Lu, C., & Ke, S. (2015) · Microsystem Technologies · doi:10.1007/s00542-015-2645-x · Cited by 145
Seel, T., Schauer, T., & Raisch, J. (2012) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2012.6402423 · Cited by 132
“A tempting alternative is to mount the sensors with a predefined orientation towards the segment or joint, as in [4] and [5].”
BackgroundJoint angle estimation in rehabilitation with inertial sensors and its integration with Kinect
Bo, A. P. L., Hayashibe, M., & Poignet, P. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6090940 · Cited by 116
“Those systems may provide high bandwidth information, but the provided estimates may be corrupted by different types of errors [3].”
BackgroundSun, Z., Zhu, M., & Lee, C. (2021) · Nanoenergy Advances · doi:10.3390/nanoenergyadv1010005 · Cited by 105
A survey on the grating based optical position encoder
Yu, H., Chen, X., Liu, C., Cai, G., & Wang, W. (2021) · Optics & Laser Technology · doi:10.1016/j.optlastec.2021.107352 · Cited by 91
Semi-Automatic Sensor-to-Body Calibration of Inertial Sensors on Lower Limb Using Gait Recording
Nazarahari, M., & Rouhani, H. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2939981 · Cited by 57
“In addition to spatiotemporal parameters of the gait, IMUs have been widely used for lower/ upper limb joint angle measurement [12], [13].”
MethodUpper limb joint angle measurement in occupational health
Álvarez, D., Alvarez, J. C., González, R. C., & López, A. M. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.997718 · Cited by 56
“Inertial sensing technology is an intense research area (Cheng and Oelmann 2010; Yang and Hsu 2010).”
BackgroundLuo, H., Wang, M., Wong, P. K.-Y., Tang, J., & Cheng, J. C. P. (2020) · Automation in Construction · doi:10.1016/j.autcon.2020.103444 · Cited by 53
Wearable Biometric Performance Measurement System for Combat Sports
Saponara, S. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2677679 · Cited by 45
“This way the complexity of the measuring system is reduced versus the state-of-art approaches using additional sensors, such as potentiometers, strain gauges, or optical devices to measure the joint angles [48].”
A Joint-Angle Estimation Method for Industrial Manipulators Using Inertial Sensors
Cantelli, L., Muscato, G., Nunnari, M., & Spina, D. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2385940 · Cited by 43
Camera marker networks for articulated machine pose estimation
Feng, C., Kamat, V. R., & Cai, H. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.09.004 · Cited by 45
Manipulator state estimation with low cost accelerometers and gyroscopes
Roan, P. R., Deshpande, N., Wang, Y., & Pitzer, B. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6385893 · Cited by 38
“…B. Pitzer are with Robert Bosch LLC. Research and Technology Center, Palo Alto, CA 94304, USA {philip.roan; benjamin.pitzer}@us.bosch.com N. Deshpande is with the Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27695, USA nadeshpa@ncsu.edu Y. Wang is…”
BackgroundMethodReconstruction of Angular Kinematics From Wrist-Worn Inertial Sensor Data for Smart Home Healthcare
Villeneuve, E., Harwin, W., Holderbaum, W., Janko, B., & Sherratt, R. S. (2017) · IEEE Access · doi:10.1109/access.2016.2640559 · Cited by 39
“With two 2D accelerometers, the CommonMode Rejection (CMR) method [25] evaluates the difference between components from both sensors and provides access to the angle [5], [7], square velocity and acceleration [4].”
Suh, Y. S., Ro, Y.-S., & Kang, H. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2181910 · Cited by 38
“In [1]– [4], the orientation of human body segments (such as arms, legs, and the upper trunk) is estimated so that human motion is tracked.”
BackgroundVihonen, J., Honkakorpi, J., Tuominen, J., Mattila, J., & Visa, A. J. E. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2544352 · Cited by 33
“In [13], sensor fusion of two-”
A Double-EKF Orientation Estimator Decoupling Magnetometer Effects on Pitch and Roll Angles
Xu, X., Sun, Y., Tian, X., Zhou, L., & Li, Y. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3060652 · Cited by 34
“In [6]–[8], they are utilized to track the robot motion of joint angles and position.”
MethodVision-Based Articulated Machine Pose Estimation for Excavation Monitoring and Guidance
Feng, C., Dong, S., Lundeen, K. M., Xiao, Y., & Kamat, V. R. (2015) · International Symposium on Automation and Robotics in Construction (ISARC) · doi:10.22260/isarc2015/0029 · Cited by 31
Joint-Space Kinematic Model for Gravity-Referenced Joint Angle Estimation of Heavy-Duty Manipulators
Vihonen, J., Mattila, J., & Visa, A. J. E. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2749918 · Cited by 35
“and distributing a number of body-fixed inertial units are feasible [32]–[34].”
BackgroundInstrumented Knee Prosthesis for Force and Kinematics Measurements
Arami, A., Simoncini, M., Atasoy, O., Ali, S., Hasenkamp, W., Bertsch, A., Meurville, E., Tanner, S., Renaud, P., Dehollain, C., et al. (2013) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2012.2226030 · Cited by 31
Muñoz-Barron, B., Rivera‐Guillen, J. R., Osornio-Rios, R. A., & Romero-Troncoso, R. D. J. (2014) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-014-0125-7 · Cited by 30
Sensor to segment calibration for magnetic and inertial sensor based motion capture systems
Liu, Y., Zhang, Y.-A., & Zeng, M. (2019) · Measurement · doi:10.1016/j.measurement.2019.03.048 · Cited by 31
A wearable system for long-term monitoring of knee kinematics
Toffola, L. D., Patel, S., Ozsecen, M. Y., Ramachandran, R., & Bonato, P. (2012) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2012.6211541 · Cited by 29
Inertial sensor-based humanoid joint state estimation
Rotella, N., Mason, S., Schaal, S., & Righetti, L. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487328 · Cited by 26
Yang, W., Zhang, X., Ma, H., & Zhang, G. (2019) · IEEE Access · doi:10.1109/access.2019.2904097 · Cited by 29
“The angular sensor based methods [1]–[3] are installed at the rotating joint or lifting joint of the cutting arm, and vibration condition accelerates the sensors damage.”
Geißler, D., Zhou, B., Bello, H., Sorysz, J., Ray, L. S. S., Javaheri, H., Rüb, M., Herbst, J., Zahn, E. F., Woop, E., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-66165-z · Cited by 29
“A common practice to evaluate a new sensing technology for its capabilities in this scope is single joint angle measurements 23–25 .”
BackgroundChow, D. H. K., Tremblay, L., Lam, C. Y., Yeung, A. W. Y., Cheng, W. H. W., & Tse, P. T. W. (2021) · Sensors · doi:10.3390/s21144633 · Cited by 26
Vision-based excavator pose estimation for automatic control
Liu, G., Wang, Q., Wang, T., Li, B., & Xi, X. (2023) · Automation in Construction · doi:10.1016/j.autcon.2023.105162 · Cited by 32
Direct Joint Space State Estimation in Robots With Multiple Elastic Joints
Chen, W., & Tomizuka, M. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2255308 · Cited by 24
“In [7] and [8], joint angle estimation was achieved utilizing an accelerometer (and a gyroscope) for each joint without the use of motor encoders.”
MethodPrinting angle sensors for foldable robots
Sun, X., Felton, S. M., Wood, R. J., & Kim, S. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7353600 · Cited by 27
“Many discrete components have been used for measuring joint angles in robotics systems, including magnetic and rotary encoders [11], [12], accelerometers, and gyroscopes [13].”
MethodXu, X., Sun, Y., Tian, X., & Zhou, L. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2962442 · Cited by 24
“[22] estimate the joint angle using the biaxial accelerometer and uniaxial gyroscope.”
MethodLee, J. K., & Jeon, T. H. (2019) · Sensors · doi:10.3390/s19245522 · Cited by 23
Instrumented prosthesis for knee implants monitoring
Arami, A., Simoncini, M., Atasoy, O., Hasenkamp, W., Ali, S., Bertsch, A., Meurville, E., Tanner, S., Dejnabadi, H., Leclercq, V., et al. (2011) · IEEE International Conference on Automation Science and Engineering (CASE) · doi:10.1109/case.2011.6042490 · Cited by 22
Li, Y., Yang Wang, A., Chase, J. G., Mattila, J., Myung, H., & Sawodny, O. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2283537 · Cited by 21
Vihonen, J., Honkakorpi, J., Mattila, J., & Visa, A. J. E. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696710 · Cited by 21
Signal Quality and Compactness of a Dual-Accelerometer System for Gyro-Free Human Motion Analysis
Villeneuve, E., Harwin, W., Holderbaum, W., Sherratt, R. S., & White, R. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2582262 · Cited by 20
Wind, H., Renner, A., Schaut, S., Albrecht, S., & Sawodny, O. (2019) · Control Engineering Practice · doi:10.1016/j.conengprac.2019.104118 · Cited by 20
Body-IMU autocalibration for inertial hip and knee joint tracking
Salehi, S., Bleser, G., Reiss, A., & Stricker, D. (2015) · EAI Endorsed Transactions on Pervasive Health and Technology · doi:10.4108/eai.28-9-2015.2261522 · Cited by 22
“However, none of the above contributions provide a method for estimating the sensor positions with respect to the adjacent joints, which is a critical information in joint angle estimation using accelerometer measurements, especially during fast rotations [7] and when modeling kinematic chains [12].”
MethodDesign of a dual-axis optoelectronic level for precision angle measurements
Fan, K., Wang, T.-H., Lin, S.-Y., & Liu, Y.-C. (2011) · Measurement Science and Technology · doi:10.1088/0957-0233/22/5/055302 · Cited by 20
Analysis of a tunnelling magneto‐resistance‐based angle transducer
Sreekantan, A. C., George, B., & Kumar, V. J. (2014) · IET Circuits Devices & Systems · doi:10.1049/iet-cds.2013.0399 · Cited by 19
Experimental evaluation of the performance of arrays of MEMS accelerometers
Moschas, F., & Stiros, S. C. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.07.031 · Cited by 17
Shape Sensing of Hyper-Redundant Robots Using an AHRS IMU Sensor Network
Lăpuşan, C., Hancu, O., & Rad, C. (2022) · Sensors · doi:10.3390/s22010373 · Cited by 17
A BSN based service for post-surgical knee rehabilitation at home
Contin, L., Nerino, R., Massazza, G., Pinto, W. G. D. S., Actis, M. V., Capacchione, P., Chimienti, A., & Pettiti, G. (2013) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets.2013.253679 · Cited by 22
Efficient Calibration of a Laser Dynamic Deflectometer
Li, Q., Zou, Q., Mao, Q., Chen, X., & Li, B. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2240932 · Cited by 17
Dual-Laser Goniometer: A Flexible Optical Angular Sensor for Joint Angle Measurement
Du, X., & Chen, Q. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2996141 · Cited by 17
“Inertial angular sensors [7]–[9], also known as inertial measurement units (IMUs), have been”
BackgroundA control method for hydraulic manipulators in automatic emulsion filling
Wang, W., Chi, H., Zhao, S., & Du, Z. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.03.001 · Cited by 16
Joint Angle Measurement Using Strategically Placed Accelerometers and Gyroscope
Vikas, V., & Crane, C. D. (2016) · Journal of Mechanisms and Robotics · doi:10.1115/1.4031299 · Cited by 15
Alizadegan, A., & Behzadipour, S. (2016) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519417500312 · Cited by 15
Urrea, C., & Muñoz, R. S. M. (2015) · Asian Journal of Control · doi:10.1002/asjc.1111 · Cited by 13
“The CMR, CMRGD and DCMR algorithms are described and compared in [5]; however, these algorithms can only be used to estimate the value of the angle of a rotational joint, calculating the acceleration on the axis for two "virtual" accelerometers in that position whose axes have rotated between themselves over an angle…”
BackgroundMethodInfluentialSaponara, S., Casarosa, G., Hambloch, P., Ciuchi, F., Fanucci, L., & Sarti, B. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2084231 · Cited by 13
Robust Calibration of MEMS Accelerometers in the Presence of Outliers
Belkhouche, F. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3163964 · Cited by 13
Joint Angle Estimation Using Accelerometer Arrays and Model-Based Filtering
Woods, C., & Vikas, V. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3200251 · Cited by 14
“This approach is similar to CMR discussed in [19].”
MethodA Local Positioning System for Loader Cranes Based on Wireless Sensors—A Feasibility Study
Cheng, P. F., Oelmann, B., & Linnarsson, F. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2121191 · Cited by 11
“These are expected from the conclusion of the previous experimental results published in [9], but what was unexpected was the result for the DCMR method in the J2 dynamic movements, which proved to be even worse than the result for the CMR method.”
MethodResultSelf-citationChang, H.-W., Georgy, J., & El‐Sheimy, N. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2381356 · Cited by 11
“MEMS-based sensors have been widely applied in orientation tracking [7], [8] and human”
MethodShim, M., Han, J. I., Choi, H. S., Ha, S. M., Kim, J., & Baek, Y. S. (2019) · Sensors · doi:10.3390/s19204418 · Cited by 11
“Nevertheless, several studies [34,35] estimated the joint angle of a manipulator with AHRSs and IMUs to utilize their advantages of contactless sensing and simple installation.”
BackgroundLow-Cost MEMS-Based AHRS Using an Adaptive Robust Error-State Kalman Filter for Motion Capture
Wang, X., Yan, J., Dai, R., Liu, W., & Zhang, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117108 · Cited by 10
Reference-Free Automated Magnetic Sensor Calibration for Angle Estimation in Smart Knee Prostheses
Arami, A., Rechenmann, J. D., & Aminian, K. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2303644 · Cited by 10
Extended Kalman Filtering for Robot Joint Angle Estimation Using MEMS Inertial Sensors
Wang, Y., Chen, W., & Tomizuka, M. (2013) · IFAC Proceedings Volumes · doi:10.3182/20130410-3-cn-2034.00021 · Cited by 10
Roadmap for the Development of at-Home Telemonitoring Systems to Augment Occupational Therapy
Stirling, L., & MacLean, J. (2015) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2015.2506729 · Cited by 11
“, [27], [65]–[69]).”
Stewart Platform Manipulator: State Estimation Using Inertia Sensors and Unscented Kalman Filter
Maged, S. A., Abouelsoud, A. A., El‐Bab, A. M. R. F., & Namerikawa, T. (2016) · International Conference on Information Science and Control Engineering · doi:10.1109/icisce.2016.244 · Cited by 10
“Different techniques for measuring the serial robot joint angle based on MEMS uniaxial gyroscopes and biaxial accelerometers are demonstrated by Cheng and Oelmann [12].”
MethodChen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Geometry-aided MEMS motion state estimation for multi-body manipulators
Vihonen, J., Honkakorpi, J., Mattila, J., & Visa, A. J. E. (2013) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2013.6584115 · Cited by 9
“Recently the MEMS-based motion state estimation has been under consideration for use in multi DOF robots [3], cranes and excavators [4], and biomedical setups [5] often based on simplified hinge joint models [6].”
MethodLoad side state estimation in robot with joint elasticity
Chen, W., & Tomizuka, M. (2012) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2012.6265906 · Cited by 8
“In [3], [4], joint angle estimation was achieved utilizing an accelerometer (and a gyroscope) for each joint without the use of motor encoders.”
MethodChen, W., & Tomizuka, M. (2012) · doi:10.1115/dscc2012-movic2012-8721 · Cited by 8
“In [8, 9], this problem was investigated utilizing an accelerometer (and a gyroscope) for each joint without the use of motor encoders.”
MethodJoint Constraints Based Dynamic Calibration of IMU Position on Lower Limbs in IMU-MoCap
Hu, Q., Liu, L., Mei, F., & Yang, C. (2021) · Sensors · doi:10.3390/s21217161 · Cited by 9
“However, the above methods do not estimate the positions of the sensors relative to the adjacent limbs, which is critical information for calculating the joint angle using IMUs, especially during fast rotations of the joint [16], and establish a motion chain model in high-speed motions [17].”
BackgroundAn improved solution for knee rehabilitation at home
Nerino, R., CONTIN, L., Tirri, A., Massazza, G., Chimienti, A., Pettiti, G., Cimolin, V., & Cau, N. (2014) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets.2014.257048 · Cited by 8
Petruska, A. J., & Meek, S. G. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094612 · Cited by 8
“3) Removing the angular and centripetal bias by adding additional geometric or previous state information to the system ([10], [11], [12], [13], [14], [15], [16]).”
BackgroundBevilacqua, A., Ciampi, G., Argent, R., Caulfield, B., & Kechadi, T. (2020) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v34i08.7028 · Cited by 10
Bui, H. T., Gagnon, C., Audet, O., Mathieu, J., & Leone, M. (2017) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2017.01.065 · Cited by 7
Estimation of Multiple Flexibilities of an Articulated System Using Inertial Measurements
Vigne, M., Khoury, A., Masselin, M., Meglio, F. D., & Petit, N. (2018) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2018.8619734 · Cited by 7
“For kinematically constrained systems, constraints may be put into the formulation of the attitude observer (see for example [10] or [11]).”
BackgroundA Flexible Detachable Capacitive Sensor Based on Nonparallel Electrodes for Joints Angle Measurement
Huang, L., Zhao, Z., Zhang, P., Wang, J., Li, Y., Bu, X., Wang, S., Jiang, Y., & Zhang, Y. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3386206 · Cited by 6
Maged, S. A., Abouelsoud, A. A., & El‐Bab, A. M. R. F. (2015) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber.2015.7288117 · Cited by 6
“Angular sensors form a critical component of the overall cost of manipulator [11].”
BackgroundMethodReyhani, M., Marko, L., Janisch, G., & Kugi, A. (2024) · Mechatronics · doi:10.1016/j.mechatronics.2024.103140 · Cited by 6
Characterization of inertial measurement unit placement on the human body upon repeated donnings
Vanegas, M. D., & Stirling, L. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299398 · Cited by 6
“Results of the use of IMUs on robotic hinges rather than on humans [9] show that if accelerometers can be placed exactly on the joint center, a simpler algorithm (common-mode rejection algorithm) can accurately predict joint-angles without the need for computationally heavy filters.”
Kaczmarek, P., Tomczyński, J., & Mańkowski, T. (2016) · IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI) · doi:10.1109/mfi.2016.7849546 · Cited by 6
“Comparison of joint angle estimation errors between the presented 3-DOF EKF, a 2-DOF EKF planar model, and independent link orientation calculation using Madgwick AHRS algorithm [6] has been provided.”
Tian, Y., Li, Y., Zhu, L., & Tan, J. (2017) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2017.8273222 · Cited by 6
“The another challenge of human motion capture with wearable sensors in free-living environments is due to the nonlinearity of the human motion [5, 6].”
BackgroundAn inertial human upper limb motion tracking method for robot programming by demonstration
Pellois, R., & Brüls, O. (2022) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2022.104201 · Cited by 6
“gles from measurement of sensors placed before and after the joint in the kinematic chain [31, 32].”
MethodŽumer, J., Slavič, J., & Boltežar, M. (2014) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2014.07.008 · Cited by 6
“The selection of the same number of accelerometers was also made in practice by Cheng [12], where he showed an improved performance of the angle determination at lower rotation speeds.”
BackgroundMethodInfluentialA Study on Optimal Placement of Accelerometers for Pose Estimation of a Robot Arm
Wijayasinghe, I. B., Saadatzi, M. N., Abubakar, S., & Popa, D. O. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460501 · Cited by 8
“Although the two-link arm is simple, the model contains typical joint configurations and nonlinear properties found in more complex robot mechanisms, and has often served as a validation platform for controller designs [19] and evaluating other IMU-based systems [15],[20].”
MethodConstraint-augmented Kalman Filter for Magnetometer-free 3D Joint Angle Determination
Lee, J. K., Jeon, T. H., & Jung, W. C. (2020) · International Journal of Control Automation and Systems · doi:10.1007/s12555-019-0948-x · Cited by 6
Unified robot and inertial sensor self-calibration
Ferguson, J. M., Ertop, T. E., Herrell, S. D., & Webster, R. J., III (2023) · Robotica · doi:10.1017/s0263574723000012 · Cited by 5
“For example, some researchers have used inertial sensors for joint angle measurement instead of traditional angle transducers (e.g. encoders) [14].”
BackgroundChamorro, G. I. D. L. H., Mercado-Aguirre, I. M., & Contreras-Ortiz, S. H. (2014) · International Congress of Engineering Mechatronics and Automation (CIIMA) · doi:10.1109/ciima.2014.6983436 · Cited by 7
“Therefore, they are not able to measure angles in horizontal planes [3].”
BackgroundConstraints of accelerometer-based range of motion estimation
Thiemjarus, S., Poomchoompol, P., Methasate, I., & Theeramunkong, T. (2012) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2012.6211641 · Cited by 5
A wearable system for biosignal monitoring in weightlifting
Mercado-Aguirre, I. M., Mercado-Medina, E. L., Chavarro-Hernandez, Z. D., Domínguez-Jiménez, J. A., & Contreras-Ortiz, S. H. (2016) · Sports Engineering · doi:10.1007/s12283-016-0212-z · Cited by 6
A novel method to assess angle sensor performance for wearable exoskeletal joint kinematics
Bolus, N. B., Kogler, G. F., & Inan, O. T. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591387 · Cited by 6
“Inertial sensors—accelerometers, gyroscopes, or the all-inclusive “inertial measurement unit” (IMU)—have been suggested as possible avenues to joint angle measurement [15]– [17], and while their reputation as flexible-use, non-contact devices seems attractive, they suffer from many limitations: at least two sensors ar…”
BackgroundAn accelerometer-based embedded system-on-chip for measuring human-body joint angles
Caballero, A., & López, J. J. C. (2013) · Pan American Health Care Exchanges · doi:10.1109/pahce.2013.6568247 · Cited by 5
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
Parada, R. A. D., & Martínez-Santos, J. C. (2014) · International Congress of Engineering Mechatronics and Automation (CIIMA) · doi:10.1109/ciima.2014.6983443 · Cited by 4
“These deliver acceleration values by a vector that validates its components in the XYZ axes [3].”
BackgroundVisual Sensor Target Tracking and Localization Method for Automatic Excavators
Liu, G., Wang, Q., Wang, T., Li, B., & Xi, X. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3407971 · Cited by 5
“Traditional measurement methods rely on contact sensors, which are mounted on manipulators, such as inertial measurement unit (IMU) and cylinder displacement sensors [2], [3].”
MethodVihonen, J., Honkakorpi, J., Mattila, J., & Visa, A. J. E. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6906607 · Cited by 4
Vihonen, J., Honkakorpi, J., Koivumäki, J., Mattila, J., & Visa, A. J. E. (2014) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2014.6878139 · Cited by 4
Method for the Determination of Relative Joint Axes for Wearable Inertial Sensor Applications
Fry, K. E., Chen, Y., & Howard, A. (2021) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros51168.2021.9636686 · Cited by 4
“In some applications, the sensor is placed in such a way that the sensor axes align with the joint axes [14-15].”
BackgroundHasan, D. S., & Hamarash, I. I. (2017) · Journal of Applied and Physical Sciences · doi:10.20474/japs-3.2.3 · Cited by 3
Calibration of visual measurement system for excavator manipulator pose
Liu, G., Wang, Q., Li, B., & Xi, X. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ad37d2 · Cited by 3
“Regarding the measurement of excavator manipulator pose, traditional methods rely on contact sensors [4, 5] mounted on the manipulators, such as hydro-cylinder displacement sensors, inertial measurement units (IMUs), and inclinomet-ers.”
A method for shoulder range-of-motion estimation using a single wireless sensor node
Thiemjarus, S., Marukatat, S., & Poomchoompol, P. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610896 · Cited by 3
FIBER-OPTIC GONIOMETER FOR MEASURING JOINT ANGLES
Jung, G.-I., KIM, J.-S., Lee, T.-H., Choi, J.-H., Oh, H.-B., Kim, A.-H., & Jun, J. (2014) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519414400144 · Cited by 3
Circular deformation estimation for a flexible link
Vihonen, J., Mäkinen, P., Mattila, J., & Visa, A. J. E. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234061 · Cited by 3
“, [5], [6] and the references therein.”
A dynamic angle metrology system based on fibre-optic gyroscope and rotary table
Chen, L., Zhou, Y., Zhang, D., Shu, X., & Liu, C. (2019) · Metrology and Measurement Systems · doi:10.24425/mms.2019.129574 · Cited by 3
“FOGs have the advantages of high theoretical precision, all-solid state, high reliability and low cost, and play an important role in high-precision angular velocity measurement [22, 23].”
Background
Metadata
- Authors
- Cheng, P., & Oelmann, B.
- Affiliations
- Mid Sweden University (SE)
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-02
- Volume
- 59
- Issue
- 2
- Pages
- 404-414
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2116716880
- Cited by
- 140
- References
- 14
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 9 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 7 · 2019: 12 · 2018: 5 · 2017: 13 · 2016: 10 · 2015: 16 · 2014: 12 · 2013: 10 · 2012: 9
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Keywords
- joint angle measurement, MEMS accelerometer, MEMS gyroscope, inertial sensors, sensor fusion, rigid body kinematics, non-contact sensing, sensor calibration, angular accuracy, angular noise, robot manipulators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.