Reducing Drifts in the Inertial Measurements of Wrist and Elbow Positions
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this paper, we present an inertial-sensor-based monitoring system for measuring the movement of human upper limbs. Two wearable inertial sensors are placed near the wrist and elbow joints, respectively. The measurement drift in segment orientation is dramatically reduced after a Kalman filter is applied to estimate inclinations using accelerations and turning rates from gyroscopes. Using premeasured lengths of the upper and lower arms, we compute the position of the wrist and elbow joints via a proposed kinematic model. Experimental results demonstrate that this new motion capture system, in comparison to an optical motion tracker, possesses an RMS position error of less than 0.009 m, with a drift of less than 0.005 ms-1in five daily activities. In addition, the RMS angle error is less than 3°. This indicates that the proposed approach has performed well in terms of accuracy and reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647 · cited 2×
“Based on a study reported in [18], the proposed Kalman filter in this work considers an error model of the measurements”
MethodMihailidis, A., Carmichael, B., & Boger, J. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.834386 · Cited by 208 · cited 1×
“UMAN motion capture systems provide the best interface to the understanding of trajectory planning and formations in the central nervous system [1], which has enormously benefited research in biomechanics, rehabilitation, humanoid robotics, and human–computer interfaces (e.g., [2]–[5]).”
BackgroundInertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106 · cited 1×
“To register the estimates of these two systems, we applied a static calibration method, as reported in [21].”
MethodSelf-citation
Cited by
Advanced internet of things for personalised healthcare systems: A survey
Qi, J., Yang, P., Min, G., Amft, O., Dong, F., & Xu, L. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.018 · Cited by 406
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
“7) to 4.83u.32 The study of Zhou and Hu10 confirmed the effectiveness of the Kalman filter, providing results before and after the filter of 14.62– 2.13u.”
BackgroundInfluentialSurvey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309
“Ten articles reported results for various complex movements [29-39].”
BackgroundQi, J., Yang, P., Waraich, A., Deng, Z., Zhao, Y., & Yang, Y. (2018) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2018.09.002 · Cited by 199
“[147] 1 3D ACC, 1 3D gyro, 1 3D magnetic sensor.”
A Linear Kalman Filter for MARG Orientation Estimation Using the Algebraic Quaternion Algorithm
Valenti, R. G., Dryanovski, I., & Xiao, J. (2016) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2498998 · Cited by 183
“They are widely used in aerospace applications [7], [8], human motion analysis [9]–[11], and robotics [12], [13].”
BackgroundBouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133
“STATIC calibrations are frequently used in the literature [8,9,23,24] since they are easy and quick to perform, consider an anatomical pose, and do not require strict MIMU sensor orientation on human segments.”
BackgroundSchall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
Motion capture sensing techniques used in human upper limb motion: a review
Yahya, M., Shah, J. A., Kadir, K. A., Yusof, Z. M., Khan, S., & Warsi, A. (2019) · Sensor Review · doi:10.1108/sr-10-2018-0270 · Cited by 82
Steins, D., Dawes, H., Esser, P., & Collett, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-36 · Cited by 71
A Mobile Motion Capture System Based on Inertial Sensors and Smart Shoes
Jung, P.-G., Oh, S., Lim, G., & Kong, K. (2014) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.4025207 · Cited by 44
Metadata
- Authors
- Zhou, H., & Hu, H.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-03
- Volume
- 59
- Issue
- 3
- Pages
- 575-585
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2172233963
- Cited by
- 120
- References
- 4
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.