The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Fast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD Optimization
Abstract
Recent applications of model-based iterative reconstruction (MBIR) algorithms to multislice helical CT reconstructions have shown that MBIR can greatly improve image quality by increasing resolution as well as reducing noise and some artifacts. However, high computational cost and long reconstruction times remain as a barrier to the use of MBIR in practical applications. Among the various iterative methods that have been studied for MBIR, iterative coordinate descent (ICD) has been found to have relatively low overall computational requirements due to its fast convergence. This paper presents a fast model-based iterative reconstruction algorithm using spatially nonhomogeneous ICD (NH-ICD) optimization. The NH-ICD algorithm speeds up convergence by focusing computation where it is most needed. The NH-ICD algorithm has a mechanism that adaptively selects voxels for update. First, a voxel selection criterion VSC determines the voxels in greatest need of update. Then a voxel selection algorithm VSA selects the order of successive voxel updates based upon the need for repeated updates of some locations, while retaining characteristics for global convergence. In order to speed up each voxel update, we also propose a fast 1-D optimization algorithm that uses a quadratic substitute function to upper bound the local 1-D objective function, so that a closed form solution can be obtained rather than using a computationally expensive line search algorithm. We examine the performance of the proposed algorithm using several clinical data sets of various anatomy. The experimental results show that the proposed method accelerates the reconstructions by roughly a factor of three on average for typical 3-D multislice geometries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Constrained restoration and the recovery of discontinuities
Geman, D., & Reynolds, G. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.120331 · Cited by 1,085
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Self-citationA generalized Gaussian image model for edge-preserving MAP estimation
Bouman, C., & Sauer, K. (1993) · IEEE Transactions on Image Processing · doi:10.1109/83.236536 · Cited by 884
Self-citationStatistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
On the convergence of the coordinate descent method for convex differentiable minimization
Luo, Z. Q., & Tseng, P. (1992) · Journal of Optimization Theory and Applications · doi:10.1007/bf00939948 · Cited by 502
A local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
Self-citationDistance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
A unified approach to statistical tomography using coordinate descent optimization
Bouman, C. A., & Sauer, K. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.491321 · Cited by 442
Self-citationMonotonic algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802758 · Cited by 351
An outlook on x‐ray CT research and development
Wang, G., Yu, H., & De Man, B. (2008) · Medical Physics · doi:10.1118/1.2836950 · Cited by 341
Penalized maximum-likelihood image reconstruction using space-alternating generalized EM algorithms
Fessler, J. A., & Hero, A. O. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.465106 · Cited by 299
Multidimensional digital image representations using generalized Kaiser–Bessel window functions
Lewitt, R. M. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.001834 · Cited by 292
Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
Mumcuoglu, E. U., Leahy, R., Cherry, S. R., & Zhou, Z. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363099 · Cited by 282
Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction
Fessler, J. A., Ficaro, E. P., Clinthorne, N. H., & Lange, K. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563662 · Cited by 222
Whiting, B. R., Massoumzadeh, P., Earl, O. A., O'Sullivan, J. A., Snyder, D. L., & Williamson, J. F. (2006) · Medical Physics · doi:10.1118/1.2230762 · Cited by 198
Total variation regulated EM algorithm [SPECT reconstruction]
Panin, V. Y., Zeng, G. L., & Gullberg, G. T. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.819305 · Cited by 183
Noise and resolution in images reconstructed with FBP and OSC algorithms for CT
Ziegler, A., Köhler, T., & Proksa, R. (2007) · Medical Physics · doi:10.1118/1.2409481 · Cited by 110
Total variation regulated EM algorithm
Panin, V., Zeng, G. L., & Gullberg, G. T. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.773841 · Cited by 100
Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware
Kachelrieß, M., Knaup, M., & Bockenbach, O. (2007) · Medical Physics · doi:10.1118/1.2710328 · Cited by 97
Parallelizable Bayesian tomography algorithms with rapid, guaranteed convergence
Zheng, J., Saquib, S. S., Sauer, K. D., & Bouman, C. A. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.869186 · Cited by 54
Self-citationPractical Considerations for GPU-Accelerated CT
Mueller, K. D., & Xu, F. (2006) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2006.1625135 · Cited by 39
Noise properties of iterative reconstruction techniques in low-dose CT scans
Do, S., Kalra, M. K., Liang, Z., et al. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.811597 · Cited by 1
Cited by
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
Plug-and-Play priors for model based reconstruction
Venkatakrishnan, S. V., Bouman, C. A., & Wohlberg, B. (2013) · 2013 IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2013.6737048 · Cited by 1,178
Self-citationCT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
State of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Metadata
- Authors
- Yu, Z., Thibault, J.-B., Bouman, C. A., Sauer, K. D., & Hsieh, J.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2011-01
- Volume
- 20
- Issue
- 1
- Pages
- 161-175
- ISSN
- 1057-7149 (ISSN-L)
- 1941-0042
- OpenAlex
- W1986262252
- Cited by
- 290
- References
- 24
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.