Modified Solenoid Coil That Efficiently Produces High Amplitude AC Magnetic Fields With Enhanced Uniformity for Biomedical Applications
Open accessThe DOI matches its Crossref record.
Abstract
volume of interest. Two-dimensional finite element analysis (2D-FEA) was used to design a coil generating a targeted peak AMF amplitude along the coil axis of ~100 kA/m (peak-to-peak) at a frequency of 150 kHz while maintaining field uniformity to >90% of peak for a specified volume. This field uniformity was realized by forming the turns from cylindrical sections of copper plate and by adding flux concentrating rings to both ends of the coil. Following construction, the field profile along the axes of the coil was measured. An axial peak field value of 95.8 ± 0.4 kA/m was measured with 650 V applied to the coil and was consistent with the calculated results. The region of axial field uniformity, defined as the distance over which field ≥90% of peak, was also consistent with the simulated results. We describe the utility of such a device for calorimetric measurement of nanoparticle heating for cancer therapy and for magnetic fluid hyperthermia in small animal models of human cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mahmoudi, K., Bouras, A., Bozec, D., Ivkov, R., & Hadjipanayis, C. (2018) · International Journal of Hyperthermia · doi:10.1080/02656736.2018.1430867 · Cited by 414
Self-citationWildeboer, R. R., Southern, P., & Pankhurst, Q. A. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/49/495003 · Cited by 392
Improved tissue cryopreservation using inductive heating of magnetic nanoparticles
Manuchehrabadi, N., Gao, Z., Zhang, J., Ring, H. L., Shao, Q., Liu, F., McDermott, M., Fok, A., Rabin, Y., Brockbank, K. G. M., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aah4586 · Cited by 305
Bordelon, D. E., Cornejo, C., Grüttner, C., Westphal, F., DeWeese, T. L., & Ivkov, R. (2011) · Journal of Applied Physics · doi:10.1063/1.3597820 · Cited by 142
Self-citationRF heating of magnetic nanoparticles improves the thawing of cryopreserved biomaterials
Etheridge, M. L., Xu, Y., Rott, L., Choi, J., Glasmacher, B., & Bischof, J. C. (2014) · TECHNOLOGY · doi:10.1142/s2339547814500204 · Cited by 124
Vitrification and Nanowarming of Kidneys
Sharma, A., Rao, J. S., Han, Z., Gangwar, L., Namsrai, B., Gao, Z., Ring, H. L., Magnuson, E., Etheridge, M., Wowk, B., et al. (2021) · Advanced Science · doi:10.1002/advs.202101691 · Cited by 105
The impact of data selection and fitting on SAR estimation for magnetic nanoparticle heating
Ring, H. L., Sharma, A., Ivkov, R., & Bischof, J. C. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1810332 · Cited by 40
Self-citation
Metadata
- Authors
- Bordelon, D. E., Goldstein, R. C., Nemkov, V. S., Kumar, A., Jackowski, J. K., DeWeese, T. L., & Ivkov, R.
- Venue
- IEEE Transactions on Magnetics
- Published
- 2012-01
- Volume
- 48
- Issue
- 1
- Pages
- 47-52
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2041205380
- Cited by
- 78
- References
- 0
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.