The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Design and control of an exoskeleton for the elderly and patients
Abstract
Recently, the exoskeletal power assistive equipment, which is a kind of wearable robot, has been widely developed to help human body motion. The exoskeleton for elderly people and patients, however, has some limitations due to the weight and volume of the equipment. In this paper, a tendon-driven exoskeletal power assistive device, exoskeleton for patients and the old by the Sogang University (EXPOS), is proposed as a feasible solution. In case of EXPOS, the caster walker carries heavy items such as motors, drivers, controllers, and batteries so that the weight and volume of the wearable exoskeleton are minimized. The tendon-connecting motors and pulleys of hip and knee generate the assistive power according to the requirement of the users. In this paper, the design concepts of the EXPOS, sensing techniques, and control methods are discussed
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
On the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Zoss, A., Kazerooni, H., & Chu, A. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545453 · Cited by 305
Incidence and prevalence of multiple sclerosis in Olmsted County, Minnesota, 1985–2000
Mayr, W. T., Pittock, S. J., McClelland, R. L., Jorgensen, N. W., Noseworthy, J. H., & Rodriguez, M. (2003) · Neurology · doi:10.1212/01.wnl.0000094316.90240.eb · Cited by 243
Performances of Hill-Type and Neural Network Muscle Models—Toward a Myosignal-Based Exoskeleton
Rosén, J., Fuchs, M. B., & Arcan, M. (1999) · Computers and Biomedical Research · doi:10.1006/cbmr.1999.1524 · Cited by 142
Stand alone wearable power assisting suit - sensing and control systems
Yamamoto, K., Ishii, M., Noborisaka, H., & Hyodo, K. (2005) · IEEE RO-MAN · doi:10.1109/roman.2004.1374841 · Cited by 106
Kasaoka, K., & Sankai, Y. (2002) · doi:10.1109/iros.2001.977204 · Cited by 104
Cited by
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“rolled on a cart [72] or carried by a second person) or is carried by the user himself in a way that may be impractical as a product, yet informative for research purposes.”
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Kong, K., Bae, J., & Tomizuka, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.2004561 · Cited by 426
Self-citationWearable soft sensing suit for human gait measurement
Mengüç, Y., Park, Y.-L., Pei, H., Vogt, D., Aubin, P. M., Winchell, E., Fluke, L., Stirling, L., Wood, R. J., & Walsh, C. J. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914543793 · Cited by 415
Design and Control of the MINDWALKER Exoskeleton
Wang, S., Wang, L., Meijneke, C., van Asseldonk, E., Hoellinger, T., Cheron, G., Ivanenko, Y., La Scaleia, V., Sylos-Labini, F., Molinari, M., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2365697 · Cited by 380
Human–Robot Interaction Control of Rehabilitation Robots With Series Elastic Actuators
Yu, H., Huang, S., Chen, G., Pan, Y., & Guo, Z. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2457314 · Cited by 356
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
A Gait Monitoring System Based on Air Pressure Sensors Embedded in a Shoe
Kong, K., & Tomizuka, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.2008803 · Cited by 301
Self-citationDynamic movement primitives in robotics: A tutorial survey
Saveriano, M., Abu-Dakka, F. J., Kramberger, A., & Peternel, L. (2023) · The International Journal of Robotics Research · doi:10.1177/02783649231201196 · Cited by 267
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258
(2008) · doi:10.1109/aim.2008.4601855 · Cited by 15
“motion capture system for objective diagnoses [1] and humancentered robots for assistance [2-6] and for rehabilitation [79].”
BackgroundSelf-citation
Metadata
- Authors
- Kong, K., & Jeon, D.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2006-08
- Volume
- 11
- Issue
- 4
- Pages
- 428-432
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2108965296
- Cited by
- 403
- References
- 11
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.